Translate this page to:
In JoVE (1)
Other Publications (1)
Articles by Alexander P. Reddington in JoVE
Biomolecular Detection employing the Interferometric Reflectance Imaging Sensor (IRIS)
Carlos A. Lopez1, George G. Daaboul2, Sunmin Ahn2, Alexander P. Reddington1, Margo R. Monroe2, Xirui Zhang2, Rostem J. Irani3, Chunxiao Yu4,5, Caroline A. Genco4,5, Marina Cretich6, Marcella Chiari6, Bennett B. Goldberg1, John H. Connor5, M. Selim Ünlü1,2
1Department of Electrical and Computer Engineering, Boston University, 2Department of Biomedical Engineering, Boston University, 3Center for Advanced Genomics Technology, Boston University, 4Department of Medicine, Section of Infectious Diseases, Boston University School of Medicine, 5Department of Microbiology, Boston University School of Medicine, 6CNR (National Research Council), Istituto di Chimica del Riconoscimento Molecolare
Quantitative, high-throughput, real-time, and label-free biomolecular detection (DNA, protein, etc.) on SiO2 surfaces can be achieved using a simple interferometric technique which relies on LED illumination, minimal optical components, and a camera. The Interferometric Reflectance Imaging Sensor (IRIS) is inexpensive, simple to use, and amenable to microarray formats.
Other articles by Alexander P. Reddington on PubMed
Multiplexed Method to Calibrate and Quantitate Fluorescence Signal for Allergen-specific IgE
Analytical Chemistry. Dec, 2011 | Pubmed ID: 22060132
Using a microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of serum. However, variation of probe immobilization on microarrays hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics. To address this problem, we have developed a calibrated, inexpensive, multiplexed, and rapid protein microarray method that directly correlates surface probe density to captured labeled secondary antibody in clinical samples. We have identified three major technological advantages of our calibrated fluorescence enhancement (CaFE) technique: (i) a significant increase in fluorescence emission over a broad range of fluorophores on a layered substrate optimized specifically for fluorescence; (ii) a method to perform label-free quantification of the probes in each spot while maintaining fluorescence enhancement for a particular fluorophore; and (iii) a calibrated, quantitative technique that combines fluorescence and label-free modalities to accurately measure probe density and bound target for a variety of antibody-antigen pairs. In this paper, we establish the effectiveness of the CaFE method by presenting the strong linear dependence of the amount of bound protein to the resulting fluorescence signal of secondary antibody for IgG, β-lactoglobulin, and allergen-specific IgEs to Ara h 1 (peanut major allergen) and Phl p 1 (timothy grass major allergen) in human serum.
