In JoVE (1)

Other Publications (2)

Articles by Ralf Engels in JoVE

 JoVE Bioengineering

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

1Jülich Centre for Neutron Science Outstation at MLZ, Forschungszentrum Jülich GmbH, 2Department of Chemistry, Louisiana State University, 3Jülich Centre for Neutron Science JCNS-1 & Institute of Complex Systems ICS-1, Forschungszentrum Jülich GmbH, 4Central Institute of Engineering, Electronics and Analytics — Electronic Systems (ZEA-2), Forschungszentrum Jülich GmbH, 5Central Institute of Engineering, Electronics and Analytics — Engineering and Technology (ZEA-1), Forschungszentrum Jülich GmbH


JoVE 54639

Other articles by Ralf Engels on PubMed

Measurement of the Nuclear Polarization of Hydrogen and Deuterium Molecules Using a Lamb-shift Polarimeter

The Review of Scientific Instruments. Oct, 2014  |  Pubmed ID: 25362391

Lamb-shift polarimeters are used to measure the nuclear polarization of protons and deuterons at energies of a few keV. In combination with an ionizer, the polarization of hydrogen and deuterium atoms was determined after taking into account the loss of polarization during the ionization process. The present work shows that the nuclear polarization of hydrogen or deuterium molecules can be measured as well, by ionizing the molecules and injecting the H2(+) (or D2(+)) ions into the Lamb-shift polarimeter.

Tuning the Instrument Resolution Using Chopper and Time of Flight at the Small-angle Neutron Scattering Diffractometer KWS-2

Journal of Applied Crystallography. Dec, 2015  |  Pubmed ID: 26664343

Following demand from the user community regarding the possibility of improving the experimental resolution, the dedicated high-intensity/extended Q-range SANS diffractometer KWS-2 of the Jülich Centre for Neutron Science at the Heinz Maier-Leibnitz Center in Garching was equipped with a double-disc chopper with a variable opening slit window and time-of-flight (TOF) data acquisition option. The chopper used in concert with a dedicated high-intensity velocity selector enables the tuning at will of the wavelength resolution Δλ/λ within a broad range, from 20% (standard) down to 2%, in a convenient and safe manner following pre-planned or spontaneous decisions during the experiment. The new working mode is described in detail, and its efficiency is demonstrated on several standard samples with known properties and on a completely new crystallizable copolymer system, which were investigated using both the conventional (static) and TOF modes.

Waiting
simple hit counter