Journal of Visualized Experiments

Sign In
New Account Forgot Password
Search
Home Browse For Authors Subscribe
< Previous Article
Next Article >
Ex vivo Mechanical Loading of Tendon
Krishna Asundi1, David Rempel2
1Department of Bioengineering, University of California, Berkeley, 2Department of Bioengineering, University of California, Berkeley; Division of Occupational Medicine, University of California, San Francisco

Sorry for the inconvenience.
This content requires the Adobe Flash Player 9 or higher.
Click Here to Get Flash

0:00 Introduction0

0:21 Subscription Lock21

0:48 Experimental system: mechanical actuators48

1:24 Loading tendon into the system84

1:36 Measuring the tendon thickness with micrometer96

2:49 Loading tendon into actuator169

6:37 Applying load to the tendon and measurements397

10:29 Disassembling the system629

10:54 Conclusion654

Injuries to the tendon (e.g., wrist tendonitis, epicondyltis) due to overuse are common in sports activities and the workplace. Most are associated with repetitive, high force hand activities. The mechanisms of cellular and structural damage due to cyclical loading are not well known. The purpose of this video is to present a new system that can simultaneously load four tendons in tissue culture. The video describes the methods of sterile tissue harvest and how the tendons are loaded onto a clamping system that is subsequently immersed into media and maintained at 37°C. One clamp is fixed while the other one is moved with a linear actuator. Tendon tensile force is monitored with a load cell in series with the mobile clamp. The actuators are controlled with a LabView program. The four tendons can be repetitively loaded with different patterns of loading, repetition rate, rate of loading, and duration. Loading can continue for a few minutes to 48 hours. At the end of loading, the tendons are removed and the mid-substance extracted for biochemical analyses. This system allows for the investigation of the effects of loading patterns on gene expression and structural changes in tendon. Ultimately, mechanisms of injury due to overuse can be studies with the findings applied to treatment and prevention.

 

You need a subscription to be able to access files

 

You must be subscribed to access this content.
Please click here to subscribe or get a FREE trial.
  1. Supplement  media CO2-independent media with Fetal Bovine serum, l-glutamine, antibiotics, and ascorbic acid
  2. Aliquot 40 ml into 50 ml centrifuge tubes (1 for each tendon)
  3. Aliquot 10 ml into 15 ml centrifuge tubes (1 for each tendon)
  4. Sterilize surgical tools, autoclave sheets, tweezers and torque wrench in autoclave
  5. Sterilize clamps and force micrometer tips by soaking in 70% ethanol overnight
  6. Harvest tendons from the rear paws of the rabbit. Rabbit should have been euthanized no more than 2 hours ago.
  7. Place tendons in 15 ml centrifuge tube filled with media
  8. Lay out a sterilized autoclave sheet to establish a sterile field
  9. Measure cross-sectional area of tendon
    1. Place micrometer tips on micrometer, align properly
    2. Grip tendon by the ends
    3. Fit thinnest tendon section in groove
    4. Have assistant place 50g weight
    5. Wait 30 seconds, read thickness (CSA = thickness x 1.3)
  10. Place tendon back in 15 ml centrifuge tube
  11. Repeat with each tendon to be loaded
  12. Remove actuator from base
  13. Cut two 15mm by 40mm strips and one 3mm by 5mm piece from sterile gauze for each tendon
  14. Roll each strip tightly and place between the grooves of the distal clamp
  15. Remove tendon from centrifuge tube and place on clamp, the distal end of the tendon on the distal clamp and the fibrocartilage region of the tendon on the proximal clamp
  16. Place 3x5 gauze piece on top of the distal end of the tendon, and secure the clamp
  17. Secure proximal clamp, ensuring tendon remains aligned between the clamps and with enough slack that it is not under tension when clamps are tightened. Tighten clamps to 1N-m
  18. Place 50ml centrifuge tube with media in base
  19. Place actuator in base
  20. Repeat with each tendon to be loaded
  21. Place base over water bath
  22. Loading Protocol
    1. Precondition tendons
    2. Apply 0.5N load, measure tendon length (this is the gauge length)
    3. Apply cyclic loading
  23. Remove actuator from base
  24. Release tendon from clamps
  25. Process tendon

The video presents a new system for the simultaneous loading of up to four live tendons in tissue culture. Typical loading durations are 2 to 48 hours. After loading, the tendons are removed and processed for gene expression. The system allows for the investigation of the effect of loading pattern on changes in genes associated with degenerative changes in the tendon. These experiments can provide some insight into mechanisms of injury associated with repetitive loading. They also provide insight into loads that can cause tissue damage. Ultimately, the results may be used to prevent and treat overuse injuries to tendons and ligaments.

Custom 4 Linear Actuator loading system Warm water bath 50 ml tubes tendons (rabbit) Sterile media

1. Asundi ,K., Kursa, K., Lotz, J.C., Rempel, D. In vitro system for applying cyclic loads to connective tissues under displacement or force control. Ann Biomed Eng. 35(7):1188-95 (2007).

2. Asundi, K.R., Rempel, D.M. Cyclic loading inhibits expression of MMP-3 but not MMP-1 in an in vitro rabbit flexor tendon model. Clin Biomech (in press).

3. Asundi, K.R., Rempel, D.M. MMP-1, IL-1β and COX-2 mRNA Expression is Modulated by Static Load in Rabbit Flexor Tendon. Ann Biomed Eng (in press).

Asundi K, Rempel D (2007). Ex vivo Mechanical Loading of Tendon. JoVE. 4. http://www.jove.com/index/details.stp?id=209, doi: 10.3791/209
Post a Question / Comment / Request

Allowed tags: i, b, u, sup, sub

Please log into your account at the top of this page or

Create a New Account.

Sign your name and post:

Email:

Post Comment

Name:

OR

Mailer.URL:

http://www.jove.com/index/details.stp?id=209

 

Subscription Required

to view this article in its entirety

Free Trial
Subscribe
Recommend to Librarian

Info

05/28/2007

Publish Date

5297 

Views

 0 

Comments

doi: 10.3791/209 

Traffic Stats

Tracking

You must be logged in to track comments.

Share this article:

 Email this Article

My Stuff (Please log in to use)

Store a note

Make a Suggestion

Is there a technique you would like to see published?  Click the button above to make a suggestion.

 

 

About Jove

 

Journal of Visualized Experiments (JoVE) is an online research journal employing visualization to increase reproducibility and transparency in biological sciences.

 

ISSN 1940-087X

 

 

Quick links

 

* Welcome  

* Browse  

* Submit  

* About  

* Editorial Board  

* Press  

* Advertising

* Contact  

* Policies

* Article Index

* Sponsors

* Press Access

* Troubleshooting

 

 

* Twitter.com/JoveJournal

* FaceBook

Subscribe

You don't have to create an account to receive email notifications. 

Please enter your email:

Submit

Copyright (C) JoVE 2006-2008 All Rights Reserved.  Powered by TARGET.  JoVE Site Version 1.893

 

 

Feedback Form