Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen Dye
Life Sciences Group, Hitachi High Technologies America
Demonstration of quantification of dsDNA using Molecular Probes PicoGreen dye and Hitachi F-7000 Fluorescence Spectrophotometer equipped with a microplate reader accessory.
Simultaneous Synthesis of Single-walled Carbon Nanotubes and Graphene in a Magnetically-enhanced Arc Plasma
Department of Mechanical and Aerospace Engineering, The George Washington University
Anodic arc discharge is one of the most practical and efficient methods to synthesize various carbon nanostructures. To increase the arc controllability and flexibility, a non-uniform magnetic field was introduced to process the one-step synthesis of large-scale graphene flakes and high-purity single-walled carbon nanotubes.
Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus (SCUVA)
1Applied Ocean Physics and Engineering, Woods Hole Oceanographic Institution, 2Environmental Science and Marine Biology, Roger Williams University, 3Marine Biology Laboratory, Whitman Center, 4Department of Biology, Providence College, 5Departments of Aeronautics and Bioengineering, California Institute of Technology
This protocol provides instructions on how to use a self-contained underwater velocimetry apparatus (SCUVA), which is designed for quantification of in situ animal-generated flows. In addition, this protocol addresses challenges posed by field conditions, and includes operator motion, predicting position of animals, and orientation of SCUVA.
Using Affordable LED Arrays for Photo-Stimulation of Neurons
Adult-born neurons expressing ChR2 can be manipulated in slice electrophysiological preparations in order to examine their contribution towards the function of olfactory neural circuits.
Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
1Department of Neurology, Universitätsmedizin Charité, 2Center for Stroke Research Berlin (CSB), Universitätsmedizin Charité, 3Berlin School of Mind and Brain, Humboldt Universität zu Berlin
Patients with visual deficits after stroke report about different constraints in daily life most likely due to variable compensatory strategies, which are difficult to differentiate in clinical routine. We present a clinical set-up which allows measurement of different compensatory head- and eye-movement-strategies and evaluating their effects on driving performance.
Development of Whispering Gallery Mode Polymeric Micro-optical Electric Field Sensors
Mechanical Engineering Department, Southern Methodist University
A high-sensitivity photonic micro sensor was developed for electric field detection. The sensor exploits the optical modes of a dielectric sphere. Changes in the external electric field perturb the sphere morphology leading to shifts in its optical modes. The electric field strength is measured by monitoring these optical shifts.
Assembly, Tuning and Use of an Apertureless Near Field Infrared Microscope for Protein Imaging
1Department of Chemistry, University of Toronto, 2Department of Chemistry, University of Wisconsin, 3Department of Chemistry, Duke University
The assembly of a nearfield infrared microscope for imaging protein aggregates is described.
Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
1Cardiology, Robotic Cardiac Electrophysiology and Arrhythmia Unit, La Paz University Hospital, 2Magnetecs Corp., 3Cardiology, Geffen School of Medicine at UCLA Los Angeles
This report provides a detailed description of a new remote navigation system based on magnetic driven forces, which has been recently introduced as a new robotic tool for human cardiac electrophysiology procedures.
Changing the Direction and Orientation of Electric Field During Electric Pulses Application Improves Plasmid Gene Transfer in vitro
1Department of Fundamentals of Electrical Engineering, Mathematics and Physics, University of Ljubljana, 2Department of Biomedical Engineering, University of Ljubljana
Gene transfection by electroporation is improved approximately two times when orientation of electric field is changed during pulse application, while cell viability is not affected. The increase in gene transfection is caused by the increase of the membrane area which is made competent for DNA entry into the cell.
Rapid PCR Thermocycling using Microscale Thermal Convection
1Department of Mechanical Engineering, Texas A&M University, 2Department of Mechanical Engineering and Department of Nuclear Engineering, Texas A&M University, 3Department of Chemical Engineering, Texas A&M University
We describe a novel method to perform DNA replication via the polymerase chain reaction (PCR). Thermal convection is harnessed to continuously shuttle reagents between denaturing, annealing, and extension conditions by maintaining opposing surfaces of the reactor at constant temperature. This inherently simple design promises to make rapid PCR more accessible.
Optical Scatter Microscopy Based on Two-Dimensional Gabor Filters
Department of Biomedical Engineering, Rutgers University
We demonstrate a dark-field microscopy method based on Gabor-like filtering to measure subcellular dynamics within single living cells. The technique is sensitive to alterations in the structure of organelles, such as mitochondrial fragmentation.
Determining 3D Flow Fields via Multi-camera Light Field Imaging
1Department of Mechanical Engineering, Brigham Young University, 2Naval Undersea Warfare Center, Newport, RI
A technique for performing quantitative three-dimensional (3D) imaging for a range of fluid flows is presented. Using concepts from the area of Light Field Imaging, we reconstruct 3D volumes from arrays of images. Our 3D results span a broad range including velocity fields and multi-phase bubble size distributions.
In-vivo Detection of Protein-protein Interactions on Micro-patterned Surfaces
Institute of Biophysics, Johannes Kepler Universitat Linz
This video shows experiments with subsequent analysis of protein-protein interactions by the use of micro-patterned surfaces. The approach offers the possibility to detect protein interactions in living cells and combines high throughput capabilities with the possibility to extract quantitative information.
Examining Local Network Processing using Multi-contact Laminar Electrode Recording
1Graduate School of Biomedical Science, Neuroscience Program, University of Texas, 2Department of Neurobiology and Anatomy, University of Texas
A fundamental issue in our understanding of cortical circuitry is how networks in different cortical layers encode sensory information. Here we describe electrophysiological techniques utilizing multi-contact laminar electrodes to record single-units and local field potentials and present analyses to identify cortical layers.
Linking Predation Risk, Herbivore Physiological Stress and Microbial Decomposition of Plant Litter
1School of Forestry and Environmental Studies, Yale University, 2Department of Biological Sciences, Virginia Tech, 3Department of Ecology, Evolution and Behavior, The Hebrew University of Jerusalem
We present methods to evaluate how predation risk can alter the chemical quality of herbivore prey by inducing dietary changes to meet demands of heightened stress, and how the decomposition of carcasses from these stressed herbivores slows subsequent plant litter decomposition by soil microbes.
Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
1Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 2Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, 3Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 4Bioengineering, University of Illinois at Urbana-Champaign
Dielectrophoresis (DEP) is an effective method to manipulate cells. Printed circuit boards (PCB) can provide inexpensive, reusable and effective electrodes for contact-free cell manipulation within microfluidic devices. By combining PDMS-based microfluidic channels with coverslips on PCBs, we demonstrate bead and cell manipulation and separation within multichannel microfluidic devices.
Facilitating the Analysis of Immunological Data with Visual Analytic Techniques
1Department of Paediatrics, Division of Infectious and Immunological Diseases, Child and Family Research Institute, University of British Columbia, 2Department of Computer Science, University of British Columbia, 3Department of Psychology, University of British Columbia
Visual analytics (VA) is a new approach of analyzing data interactively. In this video, we discuss the data overload problem brought on by high-throughput biological experiments, and propose VA as a solution to such problem. The video demonstrates analysis within and between immunological datasets using a VA tool called Tableau.
Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone
1Electrical Engineering Department, University of California, Los Angeles, 2Bioengineering Department, University of California, Los Angeles, 3California NanoSystems Institute (CNSI), University of California, Los Angeles
We review our recent results on the integration of fluorescent microscopy and imaging flow cytometry tools on a cell-phone using compact and cost-effective opto-fluidic attachments. These cell-phone based micro-analysis devices might be useful for cytometric analysis, such as performing various cell counting tasks as well as for high-throughput screening of e.g., water samples in resource limited settings.
Presynaptically Silent Synapses Studied with Light Microscopy
1Department of Psychiatry, Washington University School of Medicine, 2Department of Anatomy, Washington University School of Medicine, 3Department of Neurobiology, Washington University School of Medicine
Glutamatergic synapses can switch from an active mode to a silent mode. We demonstrate that presynaptic activity status in dissociated culture of rodent neurons is visualized using a fixable form of the FM1-43 dye to visualize active synapses and immunostaining with vGluT-1 antibody to visualize all glutamate synapses.
Quantitative Analysis of Random Migration of Cells Using Time-lapse Video Microscopy
1Department of Biochemistry and Molecular Biology, LSU School of Medicine, 2Department of Oral Biology, LSU School of Dentistry, 3Stanley S. Scott Cancer Center, LSU School of Medicine
This method allows monitoring of cells in real time and quantitative measurements of different cell migration parameters such as speed, displacement, and velocity. Unlike the traditional methods, this real time approach is not based on endpoint quantitative migration measurements; instead it allows monitoring and calculating different parameters continuously.
JoVE 4th Issue
Combining Peripheral Nerve Grafting and Matrix Modulation to Repair the Injured Rat Spinal Cord
Department of Neurobiology and Anatomy, Drexel University College of Medicine
Traumatic injury to the spinal cord disrupts communication with the brain. To restore lost connectivity we utilize a peripheral nerve graft to provide a substratum for regenerating fibers in combination with neurotrophic factors and matrix-modulating enzymes to remove inhibitory molecules to promote long distance growth.
Transverse Aortic Constriction in Mice
1Department of Molecular Physiology and Biophysics, Baylor College of Medicine (BCM), 2The Margaret M. and Albert B. Alkek Department of Medicine, Baylor College of Medicine (BCM)
Transverse aortic constriction (TAC) in the mouse is a commonly used experimental model to study mechanisms underlying cardiac hypertrophy and heart failure development. Here, we describe procedures to constrict the aorta to create a reproducible degree of cardiac hypertrophy in mice.
Multifocal Electroretinograms
John A. Moran Eye Center, University of Utah
The development of the multifocal electroretinogram (mfERG) is an important advance in the diagnosis and characterization of retinopathy. Multifocal electroretinograms are a mathematical average of an approximation of a b-wave. Software programs can derive ERGs from more than a hundred retinal areas in a few minutes per eye. Scotomas and retinal dysfunction can be mapped and quantified.
March 2013: This Month in JoVE
1Department of Ophthalmology, Massachusetts Eye and Ear, 2JoVE Content Production
Here are some highlights from the March 2013 issue of Journal of Visualized Experiments (JoVE).
Principles of Rodent Surgery for the New Surgeon
Charles River, Research Models and Services
Before attempting surgery, a new surgeon should have training in basic surgical techniques and concepts. This article will present basic surgical considerations with an emphasis on rodents.
Introducing Shear Stress in the Study of Bacterial Adhesion
Blood vessels as a target for infection, Paris center for cardiovascular research, INSERM U970
During the infection process, a key step is the adhesion of pathogens with host cells. In most instances this adhesion step occurs in the presence of mechanical stress generated by flowing liquid. We describe a technique that introduces shear stress as an important parameter in the study of bacterial adhesion.
Monitoring Cleaved Caspase-3 Activity and Apoptosis of Immortalized Oligodendroglial Cells using Live-cell Imaging and Cleaveable Fluorogenic-dye Substrates Following Potassium-induced Membrane Depolarization
Department of Molecular and Cellular Biology, University of Guelph
Live-cell imaging of caspase-3 mediated apoptosis in immortalized N19-oligodendrocyte cell cultures using the NucView 488 caspase-3 substrate. This technique is applicable for programmed cell death assays in real-time in a variety of cell types and tissues.
Corneal Donor Tissue Preparation for Endothelial Keratoplasty
1Department of Ophthalmology, University of Michigan, 2MidWest Eye Banks
Endothelial corneal transplantation is a surgical technique for treatment of posterior corneal diseases. Mechanical microkeratome dissection to prepare tissue results in thinner, more symmetric grafts with less endothelial cell loss and improved outcomes. Dissections can be performed at the eye bank prior to corneal transplantation surgery.
Echo Particle Image Velocimetry
Mechanical Engineering Department, University of New Hampshire
An echo particle image velocimetry (EPIV) system capable of acquiring two-dimensional fields of velocity in optically opaque fluids or through optically opaque geometries is described, and validation measurements in pipe flow are reported.
Pre-Roll Demo (Standard) - ADVERTISEMENT
For both scientific and animal welfare reasons, training in basic surgical concepts and techniques should be undertaken before ever seeking to perform surgery on a rodent. Students, post-doctoral scholars, and others interested in performing surgery on rodents as part of a research protocol may not have had formal surgical training as part of their required coursework. Surgery itself is a technical skill, and one that will improve with practice. The principles of aseptic technique, however, often remain unexplained or untaught. For most new surgeons, this vital information is presented in piecemeal fashion or learned on the job, neither of which is ideal. It may also make learning how to perform a particular surgery difficult, as the new surgeon is learning both a surgical technique and the principles of asepsis at the same time. This article summarizes and makes recommendations for basic surgical skills and techniques necessary for successful rodent surgery. This article is designed to supplement hands-on training by the user's institution.
Pre-Roll Demo (Premium) - ADVERTISEMENT
For both scientific and animal welfare reasons, training in basic surgical concepts and techniques should be undertaken before ever seeking to perform surgery on a rodent. Students, post-doctoral scholars, and others interested in performing surgery on rodents as part of a research protocol may not have had formal surgical training as part of their required coursework. Surgery itself is a technical skill, and one that will improve with practice. The principles of aseptic technique, however, often remain unexplained or untaught. For most new surgeons, this vital information is presented in piecemeal fashion or learned on the job, neither of which is ideal. It may also make learning how to perform a particular surgery difficult, as the new surgeon is learning both a surgical technique and the principles of asepsis at the same time. This article summarizes and makes recommendations for basic surgical skills and techniques necessary for successful rodent surgery. This article is designed to supplement hands-on training by the user's institution.
Bringing the Visible Universe into Focus with Robo-AO
1Caltech Optical Observatories, California Institute of Technology, 2Department of Astronomy, California Institute of Technology, 3Dunlap Institute for Astronomy and Astrophysics, University of Toronto, 4Inter-University Centre for Astronomy & Astrophysics, 5Observatories of the Carnegie Institution for Science, 6Benoziyo Center for Astrophysics, Weizmann Institute of Science
Light from astronomical objects must travel through the earth's turbulent atmosphere before it can be imaged by ground-based telescopes. To enable direct imaging at maximum theoretical angular resolution, advanced techniques such as those employed by the Robo-AO adaptive-optics system must be used.
Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures
1Department of Radiology, University of Washington, 2Department of Bioengineering, University of Washington
This work describes basic procedures of noninvasive small animal MRI and MRS in vivo.
Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
1U.S. Department of Agriculture, 2Department of Viticulture and Enology, University of California - Davis, 3Hawkesbury Institute for the Environment, University of Western Sydney, 4Advanced Light Source, Lawrence Berkeley National Lab, 5Citrus Research & Education Center, University of Florida
High resolution x-ray computed tomography (HRCT) is a non-destructive diagnostic imaging technique that can be used to study the structure and function of plant vasculature in 3D. We demonstrate how HRCT facilitates exploration of xylem networks across a wide range of plant tissues and species.
Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
School of Engineering, University of Glasgow
This protocol outlines the simulation, fabrication and characterization of THz metamaterial absorbers. Such absorbers, when coupled with an appropriate sensor, have applications in THz imaging and spectroscopy.
A Galvanotaxis Assay for Analysis of Neural Precursor Cell Migration Kinetics in an Externally Applied Direct Current Electric Field
1Institute for Biomaterials and Biomedical Engineering, University of Toronto, 2Lyndhurst Centre, Toronto Rehabilitation Institute, 3Department of Surgery, University of Toronto
In this protocol we demonstrate how to construct custom chambers that permit the application of a direct current electric field to enable time-lapse imaging of adult brain derived neural precursor cell translocation during galvanotaxis.
Calcium Imaging of Cortical Neurons using Fura-2 AM
1Department of Neurobiology, Stanford University, 2Department of Neurobiology, Stanford University School of Medicine
Calcium signals play a key role in many cellular processes including gene expression, survival and differentiation. Here we demonstrate how to perform calcium imaging using Fura-2 AM. Calcium imaging is a valuable tool to study the regulation of intracellular calcium in real time and its regulation of signaling cascades.
Electron Spin Resonance Micro-imaging of Live Species for Oxygen Mapping
Schulich Faculty of Chemistry, The Technion, Israel Institute of Technology
This protocol describes a method for micron-scale three-dimensional imaging of oxygen concentration in the immediate environment of live cells by electron spin resonance microscopy.
Investigating Outer Hair Cell Motility with a Combination of External Alternating Electrical Field Stimulation and High-speed Image Analysis
Division of Cell Biology and Genetics, House Ear Institute
A reliable method to investigate outer hair cell (OHC) motile responses, including electromotility, slow motility and bending, is described. OHC motility is elicited by stimulation with an external alternating electrical field, and the method takes advantage of high-speed image recording, LED-based illumination, and last generation image analysis software.
Visualizing Single-molecule DNA Replication with Fluorescence Microscopy
Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School
This protocol demonstrates a simple single-molecule fluorescence microscopy technique for visualizing DNA replication by individual replisomes in real time.
High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
This article describes techniques to perform high-resolution functional magnetic resonance imaging with 1.2 mm sampling in human midbrain and subcortical structures using a 3T scanner. Use of these techniques to resolve topographic maps of visual stimulation in the human superior colliculus (SC) is given as an example.
Activation of Apoptosis by Cytoplasmic Microinjection of Cytochrome c
1Department of Cell and Developmental Biology, Neuroscience Center, University of North Carolina, 2Curriculum in Neurobiology, Neuroscience Center, University of North Carolina
In this protocol, we describe the direct cytoplasmic microinjection of cytochrome c protein into fibroblasts and primary sympathetic neurons. This technique allows for the introduction of cytochrome c protein into the cytoplasm of cells and mimics the release of cytochrome c from mitochondria, which occurs during apoptosis.
Lensless Fluorescent Microscopy on a Chip
Department of Electrical Engineering, University of California, Los Angeles
A lensless on-chip fluorescent microscopy platform is demonstrated that can image fluorescent objects over an ultra-wide field-of-view of e.g., >0.6-8 cm2 with <4μm resolution using a compressive sampling based decoding algorithm. Such a compact and wide-field fluorescent on-chip imaging modality could be valuable for high-throughput cytometry, rare-cell research and microarray-analysis.
Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
1Electrical Engineering Department, University of California, Los Angeles, 2Bioengineering Department, University of California, Los Angeles, 3California NanoSystems Institute, University of California, Los Angeles
Lensfree optical tomography is a three-dimensional microscopy technique that offers a spatial resolution of <1 μm × <1 μm × <3 μm in x, y and z dimensions, respectively, over a large imaging-volume of 15-100 mm3, which can be particularly useful for integration with lab-on-a-chip platforms.
Deficient Pms2, ERCC1, Ku86, CcOI in Field Defects During Progression to Colon Cancer
1Department of Cell Biology and Anatomy, College of Medicine, University of Arizona, Tucson, 2Southern Arizona Veterans Affairs Health Care System, Tucson, AZ, 3Department of Surgery, College of Medicine, University of Arizona, Tucson, 4Biomedical Diagnostics and Research, Tucson, AZ, 5Department of Medicine, College of Medicine, University of Arizona, Tucson
Reduced/absent expression of Pms2 and/or ERCC1 in entire crypts is a frequent event within 10 cm on each side of colonic adenocarcinomas, likely the basis of a field defect with high mutability and progression to cancer. Deficiency in Ku86 or CcOI is much less frequent in these field defects.
Electric Field-controlled Directed Migration of Neural Progenitor Cells in 2D and 3D Environments
1School of Dentistry, Cardiff Institute of Tissue Engineering & Repair, Cardiff University, 2Shandong Qianfoshan Hospital, Shandong University School of Medicine, 3Dermatology and Ophthalmology Research, Institute for Regenerative Cures, University of California at Davis
This protocol demonstrates methods used to establish 2D and 3D environments in custom-designed electrotactic chambers, which can track cells in vivo/ex vivo using time-lapse recording at the single cell level, in order to investigate galvanotaxis/electrotaxis and other cellular responses to direct current (DC) electric fields (EFs).
How to Build a Laser Speckle Contrast Imaging (LSCI) System to Monitor Blood Flow
Biomedical Engineering Department, University of Texas at Austin
This video demonstrates how to build a Laser Speckle Contrast Imaging (LSCI) system that can easily be used to monitor blood flow.
A Matrigel-Based Tube Formation Assay to Assess the Vasculogenic Activity of Tumor Cells
1Molecular and Cellular Biology Program, Morrill Science Center, University of Massachusetts, 2Pioneer Valley Life Sciences Institute, University of Massachusetts, 3Department of Veterinary and Animal Sciences, University of Massachusetts
A tube formation assay is used to evaluate vascular activity of tumor cells.
Hyperpolarized Xenon for NMR and MRI Applications
ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie
The production of hyperpolarized xenon by means of spin exchange optical pumping (SEOP) is described. This method yields a ~10000-fold enhancement of the nuclear spin polarization of Xe-129 and has applications in nuclear magnetic resonance spectroscopy and imaging. Examples of gas phase and solution state experiments are given.
