The Journal of Visualized Experiments (JoVE) is a peer reviewed, PubMed-indexed video journal. Our mission is to increase the productivity of scientific research.

Recommend to Librarian

Refine your search:

Containing Text
Filter by author or institution
GO
Filter by publication date
From:
October, 2006
Until:
Today
Filter by section
General
Neuroscience
Immunology and Infection
Clinical and Translational Medicine
Bioengineering
Applied Physics
Chemistry
 
 
 JoVE Bioengineering

Simultaneous Synthesis of Single-walled Carbon Nanotubes and Graphene in a Magnetically-enhanced Arc Plasma


JoVE 3455 2/02/2012

Department of Mechanical and Aerospace Engineering, The George Washington University

Anodic arc discharge is one of the most practical and efficient methods to synthesize various carbon nanostructures. To increase the arc controllability and flexibility, a non-uniform magnetic field was introduced to process the one-step synthesis of large-scale graphene flakes and high-purity single-walled carbon nanotubes.

 JoVE Bioengineering

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus (SCUVA)


JoVE 2615 10/31/2011

1Applied Ocean Physics and Engineering, Woods Hole Oceanographic Institution, 2Environmental Science and Marine Biology, Roger Williams University, 3Marine Biology Laboratory, Whitman Center, 4Department of Biology, Providence College, 5Departments of Aeronautics and Bioengineering, California Institute of Technology

This protocol provides instructions on how to use a self-contained underwater velocimetry apparatus (SCUVA), which is designed for quantification of in situ animal-generated flows. In addition, this protocol addresses challenges posed by field conditions, and includes operator motion, predicting position of animals, and orientation of SCUVA.

 JoVE Clinical and Translational Medicine

Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects


JoVE 4427 9/18/2012

1Department of Neurology, Universitätsmedizin Charité, 2Center for Stroke Research Berlin (CSB), Universitätsmedizin Charité, 3Berlin School of Mind and Brain, Humboldt Universität zu Berlin

Patients with visual deficits after stroke report about different constraints in daily life most likely due to variable compensatory strategies, which are difficult to differentiate in clinical routine. We present a clinical set-up which allows measurement of different compensatory head- and eye-movement-strategies and evaluating their effects on driving performance.

 JoVE Applied Physics

Development of Whispering Gallery Mode Polymeric Micro-optical Electric Field Sensors


JoVE 50199 1/29/2013

Mechanical Engineering Department, Southern Methodist University

A high-sensitivity photonic micro sensor was developed for electric field detection. The sensor exploits the optical modes of a dielectric sphere. Changes in the external electric field perturb the sphere morphology leading to shifts in its optical modes. The electric field strength is measured by monitoring these optical shifts.

 JoVE Clinical and Translational Medicine

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures


JoVE 3658 4/21/2013

1Cardiology, Robotic Cardiac Electrophysiology and Arrhythmia Unit, La Paz University Hospital, 2Magnetecs Corp., 3Cardiology, Geffen School of Medicine at UCLA Los Angeles

This report provides a detailed description of a new remote navigation system based on magnetic driven forces, which has been recently introduced as a new robotic tool for human cardiac electrophysiology procedures.

 JoVE Clinical and Translational Medicine

Changing the Direction and Orientation of Electric Field During Electric Pulses Application Improves Plasmid Gene Transfer in vitro


JoVE 3309 9/12/2011

1Department of Fundamentals of Electrical Engineering, Mathematics and Physics, University of Ljubljana, 2Department of Biomedical Engineering, University of Ljubljana

Gene transfection by electroporation is improved approximately two times when orientation of electric field is changed during pulse application, while cell viability is not affected. The increase in gene transfection is caused by the increase of the membrane area which is made competent for DNA entry into the cell.

 JoVE General

Rapid PCR Thermocycling using Microscale Thermal Convection


JoVE 2366 3/05/2011

1Department of Mechanical Engineering, Texas A&M University, 2Department of Mechanical Engineering and Department of Nuclear Engineering, Texas A&M University, 3Department of Chemical Engineering, Texas A&M University

We describe a novel method to perform DNA replication via the polymerase chain reaction (PCR). Thermal convection is harnessed to continuously shuttle reagents between denaturing, annealing, and extension conditions by maintaining opposing surfaces of the reactor at constant temperature. This inherently simple design promises to make rapid PCR more accessible.

 JoVE Applied Physics

Determining 3D Flow Fields via Multi-camera Light Field Imaging


JoVE 4325 3/06/2013

1Department of Mechanical Engineering, Brigham Young University, 2Naval Undersea Warfare Center, Newport, RI

A technique for performing quantitative three-dimensional (3D) imaging for a range of fluid flows is presented. Using concepts from the area of Light Field Imaging, we reconstruct 3D volumes from arrays of images. Our 3D results span a broad range including velocity fields and multi-phase bubble size distributions.

 JoVE General

In-vivo Detection of Protein-protein Interactions on Micro-patterned Surfaces


JoVE 1969 3/19/2010

Institute of Biophysics, Johannes Kepler Universitat Linz

This video shows experiments with subsequent analysis of protein-protein interactions by the use of micro-patterned surfaces. The approach offers the possibility to detect protein interactions in living cells and combines high throughput capabilities with the possibility to extract quantitative information.

 JoVE Neuroscience

Examining Local Network Processing using Multi-contact Laminar Electrode Recording


JoVE 2806 9/08/2011

1Graduate School of Biomedical Science, Neuroscience Program, University of Texas, 2Department of Neurobiology and Anatomy, University of Texas

A fundamental issue in our understanding of cortical circuitry is how networks in different cortical layers encode sensory information. Here we describe electrophysiological techniques utilizing multi-contact laminar electrodes to record single-units and local field potentials and present analyses to identify cortical layers.

 JoVE General

Linking Predation Risk, Herbivore Physiological Stress and Microbial Decomposition of Plant Litter


JoVE 50061 3/12/2013

1School of Forestry and Environmental Studies, Yale University, 2Department of Biological Sciences, Virginia Tech, 3Department of Ecology, Evolution and Behavior, The Hebrew University of Jerusalem

We present methods to evaluate how predation risk can alter the chemical quality of herbivore prey by inducing dietary changes to meet demands of heightened stress, and how the decomposition of carcasses from these stressed herbivores slows subsequent plant litter decomposition by soil microbes.

 JoVE Bioengineering

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow


JoVE 2545 2/04/2011

1Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 2Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, 3Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 4Bioengineering, University of Illinois at Urbana-Champaign

Dielectrophoresis (DEP) is an effective method to manipulate cells. Printed circuit boards (PCB) can provide inexpensive, reusable and effective electrodes for contact-free cell manipulation within microfluidic devices. By combining PDMS-based microfluidic channels with coverslips on PCBs, we demonstrate bead and cell manipulation and separation within multichannel microfluidic devices.

 JoVE Immunology and Infection

Facilitating the Analysis of Immunological Data with Visual Analytic Techniques


JoVE 2397 1/02/2011

1Department of Paediatrics, Division of Infectious and Immunological Diseases, Child and Family Research Institute, University of British Columbia, 2Department of Computer Science, University of British Columbia, 3Department of Psychology, University of British Columbia

Visual analytics (VA) is a new approach of analyzing data interactively. In this video, we discuss the data overload problem brought on by high-throughput biological experiments, and propose VA as a solution to such problem. The video demonstrates analysis within and between immunological datasets using a VA tool called Tableau.

 JoVE Bioengineering

Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone


JoVE 50451 4/11/2013

1Electrical Engineering Department, University of California, Los Angeles, 2Bioengineering Department, University of California, Los Angeles, 3California NanoSystems Institute (CNSI), University of California, Los Angeles

We review our recent results on the integration of fluorescent microscopy and imaging flow cytometry tools on a cell-phone using compact and cost-effective opto-fluidic attachments. These cell-phone based micro-analysis devices might be useful for cytometric analysis, such as performing various cell counting tasks as well as for high-throughput screening of e.g., water samples in resource limited settings.

 JoVE General

Presynaptically Silent Synapses Studied with Light Microscopy


JoVE 1676 1/04/2010

1Department of Psychiatry, Washington University School of Medicine, 2Department of Anatomy, Washington University School of Medicine, 3Department of Neurobiology, Washington University School of Medicine

Glutamatergic synapses can switch from an active mode to a silent mode. We demonstrate that presynaptic activity status in dissociated culture of rodent neurons is visualized using a fixable form of the FM1-43 dye to visualize active synapses and immunostaining with vGluT-1 antibody to visualize all glutamate synapses.

 JoVE General

Quantitative Analysis of Random Migration of Cells Using Time-lapse Video Microscopy


JoVE 3585 5/13/2012

1Department of Biochemistry and Molecular Biology, LSU School of Medicine, 2Department of Oral Biology, LSU School of Dentistry, 3Stanley S. Scott Cancer Center, LSU School of Medicine

This method allows monitoring of cells in real time and quantitative measurements of different cell migration parameters such as speed, displacement, and velocity. Unlike the traditional methods, this real time approach is not based on endpoint quantitative migration measurements; instead it allows monitoring and calculating different parameters continuously.

 JoVE General

Combining Peripheral Nerve Grafting and Matrix Modulation to Repair the Injured Rat Spinal Cord


JoVE 1324 11/20/2009

Department of Neurobiology and Anatomy, Drexel University College of Medicine

Traumatic injury to the spinal cord disrupts communication with the brain. To restore lost connectivity we utilize a peripheral nerve graft to provide a substratum for regenerating fibers in combination with neurotrophic factors and matrix-modulating enzymes to remove inhibitory molecules to promote long distance growth.

 JoVE General

Transverse Aortic Constriction in Mice


JoVE 1729 4/21/2010

1Department of Molecular Physiology and Biophysics, Baylor College of Medicine (BCM), 2The Margaret M. and Albert B. Alkek Department of Medicine, Baylor College of Medicine (BCM)

Transverse aortic constriction (TAC) in the mouse is a commonly used experimental model to study mechanisms underlying cardiac hypertrophy and heart failure development. Here, we describe procedures to constrict the aorta to create a reproducible degree of cardiac hypertrophy in mice.

 JoVE Clinical and Translational Medicine

Multifocal Electroretinograms


JoVE 3176 12/04/2011

John A. Moran Eye Center, University of Utah

The development of the multifocal electroretinogram (mfERG) is an important advance in the diagnosis and characterization of retinopathy. Multifocal electroretinograms are a mathematical average of an approximation of a b-wave. Software programs can derive ERGs from more than a hundred retinal areas in a few minutes per eye. Scotomas and retinal dysfunction can be mapped and quantified.

 JoVE Immunology and Infection

Introducing Shear Stress in the Study of Bacterial Adhesion


JoVE 3241 9/02/2011

Blood vessels as a target for infection, Paris center for cardiovascular research, INSERM U970

During the infection process, a key step is the adhesion of pathogens with host cells. In most instances this adhesion step occurs in the presence of mechanical stress generated by flowing liquid. We describe a technique that introduces shear stress as an important parameter in the study of bacterial adhesion.

 JoVE Neuroscience

Monitoring Cleaved Caspase-3 Activity and Apoptosis of Immortalized Oligodendroglial Cells using Live-cell Imaging and Cleaveable Fluorogenic-dye Substrates Following Potassium-induced Membrane Depolarization


JoVE 3422 1/13/2012

Department of Molecular and Cellular Biology, University of Guelph

Live-cell imaging of caspase-3 mediated apoptosis in immortalized N19-oligodendrocyte cell cultures using the NucView 488 caspase-3 substrate. This technique is applicable for programmed cell death assays in real-time in a variety of cell types and tissues.

 JoVE Clinical and Translational Medicine

Corneal Donor Tissue Preparation for Endothelial Keratoplasty


JoVE 3847 6/12/2012

1Department of Ophthalmology, University of Michigan, 2MidWest Eye Banks

Endothelial corneal transplantation is a surgical technique for treatment of posterior corneal diseases. Mechanical microkeratome dissection to prepare tissue results in thinner, more symmetric grafts with less endothelial cell loss and improved outcomes. Dissections can be performed at the eye bank prior to corneal transplantation surgery.

 JoVE Application Notes

Pre-Roll Demo (Standard) - ADVERTISEMENT


JoVE 4364 1/17/2012

For both scientific and animal welfare reasons, training in basic surgical concepts and techniques should be undertaken before ever seeking to perform surgery on a rodent. Students, post-doctoral scholars, and others interested in performing surgery on rodents as part of a research protocol may not have had formal surgical training as part of their required coursework. Surgery itself is a technical skill, and one that will improve with practice. The principles of aseptic technique, however, often remain unexplained or untaught. For most new surgeons, this vital information is presented in piecemeal fashion or learned on the job, neither of which is ideal. It may also make learning how to perform a particular surgery difficult, as the new surgeon is learning both a surgical technique and the principles of asepsis at the same time. This article summarizes and makes recommendations for basic surgical skills and techniques necessary for successful rodent surgery. This article is designed to supplement hands-on training by the user's institution.

 JoVE Application Notes

Pre-Roll Demo (Premium) - ADVERTISEMENT


JoVE 4365 1/01/2012

For both scientific and animal welfare reasons, training in basic surgical concepts and techniques should be undertaken before ever seeking to perform surgery on a rodent. Students, post-doctoral scholars, and others interested in performing surgery on rodents as part of a research protocol may not have had formal surgical training as part of their required coursework. Surgery itself is a technical skill, and one that will improve with practice. The principles of aseptic technique, however, often remain unexplained or untaught. For most new surgeons, this vital information is presented in piecemeal fashion or learned on the job, neither of which is ideal. It may also make learning how to perform a particular surgery difficult, as the new surgeon is learning both a surgical technique and the principles of asepsis at the same time. This article summarizes and makes recommendations for basic surgical skills and techniques necessary for successful rodent surgery. This article is designed to supplement hands-on training by the user's institution.

 JoVE Applied Physics

Bringing the Visible Universe into Focus with Robo-AO


JoVE 50021 2/12/2013

1Caltech Optical Observatories, California Institute of Technology, 2Department of Astronomy, California Institute of Technology, 3Dunlap Institute for Astronomy and Astrophysics, University of Toronto, 4Inter-University Centre for Astronomy & Astrophysics, 5Observatories of the Carnegie Institution for Science, 6Benoziyo Center for Astrophysics, Weizmann Institute of Science

Light from astronomical objects must travel through the earth's turbulent atmosphere before it can be imaged by ground-based telescopes. To enable direct imaging at maximum theoretical angular resolution, advanced techniques such as those employed by the Robo-AO adaptive-optics system must be used.

 JoVE General

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature


JoVE 50162 4/05/2013

1U.S. Department of Agriculture, 2Department of Viticulture and Enology, University of California - Davis, 3Hawkesbury Institute for the Environment, University of Western Sydney, 4Advanced Light Source, Lawrence Berkeley National Lab, 5Citrus Research & Education Center, University of Florida

High resolution x-ray computed tomography (HRCT) is a non-destructive diagnostic imaging technique that can be used to study the structure and function of plant vasculature in 3D. We demonstrate how HRCT facilitates exploration of xylem networks across a wide range of plant tissues and species.

 JoVE Neuroscience

A Galvanotaxis Assay for Analysis of Neural Precursor Cell Migration Kinetics in an Externally Applied Direct Current Electric Field


JoVE 4193 10/13/2012

1Institute for Biomaterials and Biomedical Engineering, University of Toronto, 2Lyndhurst Centre, Toronto Rehabilitation Institute, 3Department of Surgery, University of Toronto

In this protocol we demonstrate how to construct custom chambers that permit the application of a direct current electric field to enable time-lapse imaging of adult brain derived neural precursor cell translocation during galvanotaxis.

 JoVE General

Calcium Imaging of Cortical Neurons using Fura-2 AM


JoVE 1067 1/19/2009

1Department of Neurobiology, Stanford University, 2Department of Neurobiology, Stanford University School of Medicine

Calcium signals play a key role in many cellular processes including gene expression, survival and differentiation. Here we demonstrate how to perform calcium imaging using Fura-2 AM. Calcium imaging is a valuable tool to study the regulation of intracellular calcium in real time and its regulation of signaling cascades.

 JoVE Neuroscience

Investigating Outer Hair Cell Motility with a Combination of External Alternating Electrical Field Stimulation and High-speed Image Analysis


JoVE 2965 7/18/2011

Division of Cell Biology and Genetics, House Ear Institute

A reliable method to investigate outer hair cell (OHC) motile responses, including electromotility, slow motility and bending, is described. OHC motility is elicited by stimulation with an external alternating electrical field, and the method takes advantage of high-speed image recording, LED-based illumination, and last generation image analysis software.

 JoVE Neuroscience

High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain


JoVE 3746 5/10/2012

Psychology & Neurobiology, Imaging Research Center & Center for Perceptual Systems, The University of Texas at Austin

This article describes techniques to perform high-resolution functional magnetic resonance imaging with 1.2 mm sampling in human midbrain and subcortical structures using a 3T scanner. Use of these techniques to resolve topographic maps of visual stimulation in the human superior colliculus (SC) is given as an example.

 JoVE General

Activation of Apoptosis by Cytoplasmic Microinjection of Cytochrome c


JoVE 2773 6/29/2011

1Department of Cell and Developmental Biology, Neuroscience Center, University of North Carolina, 2Curriculum in Neurobiology, Neuroscience Center, University of North Carolina

In this protocol, we describe the direct cytoplasmic microinjection of cytochrome c protein into fibroblasts and primary sympathetic neurons. This technique allows for the introduction of cytochrome c protein into the cytoplasm of cells and mimics the release of cytochrome c from mitochondria, which occurs during apoptosis.

 JoVE Bioengineering

Lensless Fluorescent Microscopy on a Chip


JoVE 3181 8/17/2011

Department of Electrical Engineering, University of California, Los Angeles

A lensless on-chip fluorescent microscopy platform is demonstrated that can image fluorescent objects over an ultra-wide field-of-view of e.g., >0.6-8 cm2 with <4μm resolution using a compressive sampling based decoding algorithm. Such a compact and wide-field fluorescent on-chip imaging modality could be valuable for high-throughput cytometry, rare-cell research and microarray-analysis.

 JoVE Bioengineering

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution


JoVE 4161 8/16/2012

1Electrical Engineering Department, University of California, Los Angeles, 2Bioengineering Department, University of California, Los Angeles, 3California NanoSystems Institute, University of California, Los Angeles

Lensfree optical tomography is a three-dimensional microscopy technique that offers a spatial resolution of <1 μm × <1 μm × <3 μm in x, y and z dimensions, respectively, over a large imaging-volume of 15-100 mm3, which can be particularly useful for integration with lab-on-a-chip platforms.

 JoVE General

Deficient Pms2, ERCC1, Ku86, CcOI in Field Defects During Progression to Colon Cancer


JoVE 1931 7/28/2010

1Department of Cell Biology and Anatomy, College of Medicine, University of Arizona, Tucson, 2Southern Arizona Veterans Affairs Health Care System, Tucson, AZ, 3Department of Surgery, College of Medicine, University of Arizona, Tucson, 4Biomedical Diagnostics and Research, Tucson, AZ, 5Department of Medicine, College of Medicine, University of Arizona, Tucson

Reduced/absent expression of Pms2 and/or ERCC1 in entire crypts is a frequent event within 10 cm on each side of colonic adenocarcinomas, likely the basis of a field defect with high mutability and progression to cancer. Deficiency in Ku86 or CcOI is much less frequent in these field defects.

 JoVE Bioengineering

Electric Field-controlled Directed Migration of Neural Progenitor Cells in 2D and 3D Environments


JoVE 3453 2/16/2012

1School of Dentistry, Cardiff Institute of Tissue Engineering & Repair, Cardiff University, 2Shandong Qianfoshan Hospital, Shandong University School of Medicine, 3Dermatology and Ophthalmology Research, Institute for Regenerative Cures, University of California at Davis

This protocol demonstrates methods used to establish 2D and 3D environments in custom-designed electrotactic chambers, which can track cells in vivo/ex vivo using time-lapse recording at the single cell level, in order to investigate galvanotaxis/electrotaxis and other cellular responses to direct current (DC) electric fields (EFs).

 JoVE General

A Matrigel-Based Tube Formation Assay to Assess the Vasculogenic Activity of Tumor Cells


JoVE 3040 9/07/2011

1Molecular and Cellular Biology Program, Morrill Science Center, University of Massachusetts, 2Pioneer Valley Life Sciences Institute, University of Massachusetts, 3Department of Veterinary and Animal Sciences, University of Massachusetts

A tube formation assay is used to evaluate vascular activity of tumor cells.

 JoVE Applied Physics

Hyperpolarized Xenon for NMR and MRI Applications


JoVE 4268 9/06/2012

ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie

The production of hyperpolarized xenon by means of spin exchange optical pumping (SEOP) is described. This method yields a ~10000-fold enhancement of the nuclear spin polarization of Xe-129 and has applications in nuclear magnetic resonance spectroscopy and imaging. Examples of gas phase and solution state experiments are given.

More Results...
Waiting
simple hit counter