The Journal of Visualized Experiments (JoVE) is a peer reviewed, PubMed-indexed video journal. Our mission is to increase the productivity of scientific research.

Recommend to Librarian

Automatic Translation

This translation into German was automatically generated through Google Translate.
English Version | Other Languages

 JoVE General

Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Core Optical Imaging Facility, University of Texas Health Science Center at San Antonio (UTHSCSA)

 

Video Article Chapters

Cite this Article: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Centonze Frohlich, V. Phase Contrast and Differential Interference Contrast (DIC) Microscopy. J. Vis. Exp. (18), e844, doi:10.3791/844 (2008).

Abstract: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Die Phasenkontrast-Mikroskopie wird häufig verwendet, um den Kontrast für eine transparente, nicht lichtabsorbierenden, biologischen Proben zu produzieren. Die Technik wurde von Zernike, im Jahre 1942, der den Nobelpreis für seine Leistung erhielt entdeckt. DIC-Mikroskopie, in den späten 1960er Jahren eingeführt wurde, wurde in der biomedizinischen Forschung beliebt, weil es Kanten der Probe strukturelle Details Highlights, bietet hochauflösende optische Schnitte von dicken Proben einschließlich Gewebezellen, Eier und Embryonen und nicht aus der Phase-Halos typischen leiden der Phasen-Kontrast-Bildern. Dieses Protokoll zeigt die Grundlagen und praktische Anwendungen dieser Mikroskopie-Techniken.

Protocol: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Der vollständige Text Protokoll für diesen experimentellen Ansatz ist in Current Protocols in Cell Biology.

Disclosures: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Acknowledgements: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

Mehrere Video-Clips zeigen, Phasenkontrast und DIC-Mikroskopie wurden von einem anderen Video-Artikel entnommen, mit dem Titel Schichten Symbiose . JoVE gnädig erkennt dieses Beitrags durch die Leadbetter Labor hergestellt.

Ask the Author: Phasenkontrast und Differential Interferenz Kontrast (DIC) Mikroskopie

8 Comments

how much will each cost

1

Reply

Posted by: abrahamSeptember 15, 2008, 1:23 PM

The systems vary widely to correlate with your needs.  I would be happy to help you further. 631-547-8501, Ned Jastromb, Product Manager, Nikon Instruments, Inc.

1.1

Reply

Posted by: jastrombSeptember 16, 2008, 11:15 AM

Excellent - I'm definitely going to use this for my students, who are from a mixed background (biologists, physicists, chemists, engineers).

2

Reply

Posted by: Dr. Una FitzGeraldSeptember 18, 2008, 8:40 AM

I've seen that there we're colored images obtained using the DIC microscopy that looks like a 3-D image. Is there an approximation using DIC to measure the depth or height difference by just interpreting color differences?

3

Reply

Posted by: KisutoMay 27, 2009, 7:42 AM

I've seen that there we're colored images obtained using the DIC microscopy that looks like a 3-D image. Is there an approximation using DIC to measure the depth or height difference by just interpreting color differences?

4

Reply

Posted by: KisutoMay 27, 2009, 7:59 AM

In article abstract, the phase-contrast microscopy is claimed to have been invented in 1942. This is incorrect. The origins of phase-contrast date back to 1934 (not a microscopy yet) and 1935 (microscopy):

Zernike F. (1934)
Diffraction theory of the knife-edge test and its improved form, the phase-contrast method.
Monthly Notices of the Royal Astronomical Society 94 (5), 377-3­84 (originally published in Dutch).
(http://esoads.eso.org/journals_service.html)

Zernike F. (1935)
Phase-contrast method in microscopical observation (in German).
Physikalische Zeitschrift 36 (22/23): 848-851
Zeitschrift für Technische Physik 16 (11): 454-457
(two identical papers)

Furthermore, the following reports (published when Zernike was only 16 or 17 years old) utilize, in a way, the principle of phase-contrast microscopy, even though only for absorbing (i.e., not phase) objects:

Rheinberg J. (1904 and 1905)
On the influence on images of gratings of phase differences amongst their spectra.
J. Roy. Microsc. Soc.; volumes-not-numbered (Part 4), 388-390; and (Part 2), 152-155.
(www.biodiversitylibrary.org/bibliography/7413)

Conrady A. (1905)
An experimental proof of phase reversal in diffraction spectra.
J. Roy. Microsc. Soc.; volume-not-numbered (Part 2), 150-152.
(www.biodiversitylibrary.org/bibliography/7413)

5

Reply

Posted by: Radek PelcMay 4, 2010, 11:14 AM

Your presentation is excellent and locked in my neurons , the corresponding text in books do not give that effect

6

Reply

Posted by: Brajendra Kumar SinhaNovember 12, 2011, 10:19 PM

Nice video.
I may be mistaken, but one of the images (around 3:47) shown as DIC appears to be phase contrast.
Also, when mentioning setting up Koehler illumination during DIC (around 4:30), the video shows the alignment of phase rings. This is not needed (since you do not need to see the back focal plane of the microscope to establish Koehler) nor, in fact, what would be observed when setting up Koehler for DIC (there would be no phase annulus in the condenser if it is set up for DIC).

7

Reply

Posted by: Eric RobertsDecember 7, 2011, 10:36 AM

The video explained well what i was trying to learn in detail....
it is really nice
Thanks

8

Reply

Posted by: ThesmiApril 5, 2012, 2:35 AM

Post a Question / Comment / Request

You must be signed in to post a comment. Please or create an account.

Waiting
simple hit counter