Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove
JoVE Science Education
Environmental Science

A subscription to JoVE is required to view this content.

 

Dissolved Oxygen in Surface Water

Overview

Source: Laboratories of Margaret Workman and Kimberly Frye - Depaul University

Dissolved oxygen (DO) measurements calculate the amount of gaseous oxygen dissolved in surface water, which is important to all oxygen-breathing life in river ecosystems, including fish species preferred for human consumption (e.g. bluegill and bass), as well as decomposer species critical to the recycling of biogeochemical materials in the system.

The oxygen dissolved in lakes, rivers, and oceans is crucial for the organisms and creatures living in it. As the amount of dissolved oxygen drops below normal levels in water bodies, the water quality is harmed and creatures begin to die. In a process called eutrophication, a body of water can become hypoxic and will no longer be able to support living organisms, essentially becoming a “dead zone.”

Eutrophication occurs when excess nutrients cause algae populations to grow rapidly in an algal bloom. The algal bloom forms dense mats at the surface of the water blocking out two essential inputs of oxygen for water: gas exchange from the atmosphere and photosynthesis in the water due to the lack of light below the mats. As dissolved oxygen levels decline below the surface, oxygen-breathing organisms die-off in large amounts, creating an increase in organic matter. The excess organic matter causes an increase in the oxygen-breathing decomposer populations in the benthic zone, which further depletes the remaining dissolved oxygen levels during the metabolic decomposition activity. Once the oxygen levels become this low, mobile oxygen-breathing species (e.g. fish) will move away, leaving no aerobic life in the water and creating a dead zone.

The Azide-Winkler titration method uses titration to determine the concentration of an unknown in a sample. Specifically, sodium thiosulfate is used to titrate iodine, which can be stoichiometrically related to the amount of dissolved oxygen in a sample.

Principles

The Azide-Winkler method is used to measure DO on site, where surface water is collected. Manganese(II) sulfate and potassium hydroxide are added to the sample, and the dissolved oxygen in the sample oxidizes the manganese and forms a brown precipitate. Azide is added in the form of a purchased alkaline iodide-azide reagent to correct for the presence of nitrites, which are found in wastewater samples and can interfere with the Winkler oxidation procedure.

MnSO4 + 2 KOH arrow Mn(OH)2 + K2SO4

4 Mn(OH)2 + O2 + 2 H2arrow 4 Mn(OH)3

Sulfuric acid is then added to acidify the solution, and the precipitate dissolves. Under these conditions, the iodide from the alkaline iodide-azide reagent in the solution is converted into iodine.

2 Mn(OH)3 + 3 H2SO4 arrow Mn2(SO4)3 + 6 H2O

Mn2(SO4)3 + 2 KI arrow 2 MnSO4 + K2SO+ 2 I2

Thiosulfate is then used to titrate the iodine in the presence of an added starch indicator.

4 Na2S2O3 + 2 I2 arrow 2 Na2S4O6 + 4 NaI

4 moles of S2O32- arrow 1 mole of O2

At the endpoint of this titration, the blue solution will turn clear. The amount of dissolved oxygen in the sample is quantified in direct proportion to the amount of thiosulfate required to reach the endpoint.

X mL S2O3 arrow X mg/L O:

Equation 1

Subscription Required. Please recommend JoVE to your librarian.

Procedure

1. Sample Dissolved Oxygen Measurement

  1. At the water collection site, use a calibrated pipette to add 2 mL manganous sulfate to a clear 300-mL BOD bottle filled with the sample water. Be careful not to introduce oxygen into the sample by inserting the pipette tip under the sample surface and carefully dispensing manganous sulfate. This will avoid creating bubbles until the sample is “fixed” and prevents change to the dissolved oxygen concentration.
  2. Using the same technique, add 2 mL alkaline iodide-azide reagent.
  3. Immediately insert the stopper, tilting the bottle slightly and quickly pushing the stopper in place so no air bubbles are trapped in the bottle.
  4. Carefully invert several times (without creating air bubbles) to mix. A floccule (floc) will form from a precipitated aggregation of material with a cloudy appearance (Figure 1).
  5. Wait until the floc in the solution has settled. Again, invert the bottle several times and wait until the floc has settled. The sample is now fixed to prevent change in dissolved oxygen content, and can be transported back to the lab and stored for up to 8 h, if needed, in a cool and dark condition.
  6. If storing, samples should be sealed using a small amount of deionized water squirted around the stopper, and the stopper should be wrapped in aluminum foil, secured with a rubber band.
  7. Pipette 2 mL of concentrated sulfuric acid into the sample by holding the pipette tip just above the sample surface. Invert carefully several times to dissolve the floc (Figure 2).
  8. In a glass flask, and using a calibrated pipette, titrate 200 mL of sample water with 0.025 N standardized sodium thiosulfate, swirling and mixing continuously until a pale straw color forms (Figure 3).
  9. Add 2 mL of starch indicator solution with a dropper and swirl to mix. Once the starch Indicator is added, the solution will turn blue (Figure 4).
  10. Continue the titration, adding one drop at a time until one drop dissipates the blue, causing the colorless endpoint. Be sure to add each drop of titrant carefully and to evenly mix each drop before adding the next. Holding the sample against a white piece of paper can help enhance visualization of the endpoint.
  11. The concentration of DO is equivalent to the volume (mL) of titrant used. Each milliliter of sodium thiosulfate added to the water sample equals 1 mg/L dissolved oxygen. 

Figure 1
Figure 1. A sample after the alkaline iodide-azide reagent has been added and mixed, showing floc formation at the top of the sample before settling.

Figure 2
Figure 2. A sample with dissolved floc after addition of sulfuric acid.

Figure 3
Figure 3. A sample after addition of sodium thiosulfate displaying a pale straw color.

Figure 4
Figure 4. A sample showing the blue color after the starch indicator is added and mixed.

Dissolved oxygen is crucial for river and lake ecosystems to support aerobic life. The Azide-Winkler titration method allows quantification of the amount of dissolved oxygen in surface water samples.

Gaseous oxygen dissolved in surface water is required for the survival of the organisms living in it; decomposers critical to recycling of biogeochemical materials in the ecosystem, or fish species preferred for human consumption. As oxygen levels fall below normal in water systems, water quality is harmed and organisms begin to die.

The Azide-Winkler titration method is a standard test to determine the concentration of dissolved oxygen in a sample. Sodium thiosulfate is used to titrate iodine, which is stochiometrically related to the amount of dissolved oxygen in the sample.

This video will illustrate the principles behind dissolved oxygen quantification, the process of performing the Azide-Winker titration, and the interpretation of dissolved oxygen measures.

Eutrophication is the introduction of excess nutrients into an ecosystem. This causes algae populations to grow rapidly into dense mats, known as algal blooms. These mats can lead to hypoxia, or low oxygen levels, by blocking out gas exchange at the surface, and prevent photosynthesis by blocking sunlight. Oxygen breathing organisms begin to die, causing an increase in organic matter, which in turn causes an increase in oxygen dependent decomposers, depleting oxygen resources yet further. Finally, mobile oxygen-dependent organisms move away, leaving a dead zone with no aerobic life.

To test the level of dissolved oxygen in a water source, the Azide-Winkler method can be used to measure dissolved oxygen directly in the field, or samples can be fixed and taken to the laboratory for further analysis.

Manganese sulfate and potassium hydroxide are added to the sample, forming manganese hydroxide. This reduces the dissolved oxygen, forming a brown precipitate. Alkaline iodide-azide reagent is added to correct for the presence of nitrates found in wastewater samples that can interfere with the oxidation procedure.

Added sulfuric acid acidifies the solution and dissolves the precipitate. This new compound oxidizes the iodide from the alkaline iodine-azide reagent to iodine.

Next, a starch indicator is added that will turn blue in the presence of iodine. Thiosulfate, which turns iodine back into iodide, is used to titrate the iodine. When the titration is complete, the blue solution will turn colorless. The amount of dissolved oxygen in the sample is proportional to the amount of thiosulfate required to turn the solution from blue to colorless.

Now that we are familiar with the principles behind measuring dissolved oxygen in water samples, let's take a look at how this is carried out in the field and the laboratory.

The experiment will begin at the collection site. First, collect the sample water in a clear 300-mL BOD bottle. Next, measure and record the temperature of water from the water source. Carefully add 2 mL manganous sulfate to the sample by inserting the pipette tip under the water surface and slowly dispense to avoid creating bubbles.

Using the same technique, add 2 mL alkaline iodine-azide reagent, and immediately insert the stopper, tilting the bottle slightly so no air is trapped in the bottle.

Carefully invert several times to mix the solution, taking care not to create air bubbles. A precipitate will form, causing a cloudy appearance. Let the precipitate in the solution settle, and then mix thoroughly by inverting the bottle several times before letting it settle again. Samples should be sealed using a small amount of deionized water squirted around the stopper, then wrapped in aluminum foil and secured with a rubber band. The sample is now fixed, and can be transported back to the laboratory.

Once the samples have been fixed, they are transported to the lab for further analysis. First, holding the pipette tip just above the sample surface, add 2 mL of concentrated sulfuric acid into the sample. Invert several times to dissolve the precipitate. Using a glass flask and calibrated pipette, titrate 200 mL of the pre-treated sample water with 0.025 N standardized sodium thiosulfate, swirling and mixing continuously until a pale straw color forms.

Once the solution is straw colored, add 2, 1-mL droplets of starch indicator solution and swirl to mix. The solution will turn blue. Continue the titration, adding one drop of sodium thiosulfate at a time and mixing slowly using a stir bar until the blue dissipates and the solution becomes colorless. Hold the sample against a white piece of paper to enhance visualization. Record the volume of thiosulfate added.

The concentration of dissolved oxygen is proportional to the volume of sodium thiosulfate added to the sample. Each milliliter added is equivalent to 1 mg/L, or parts per million, dissolved oxygen.

The maximum amount of oxygen that can be dissolved in water varies by water temperature. Dissolved oxygen measurements in mg/L are converted to percent saturation using water temperature and a conversion chart. Saturation of 91 to 110% dissolved oxygen is considered excellent; between 71 and 90% is good, 51-70% is fair, and below 50% is poor.

Dissolved oxygen levels of 6 mg/L are sufficient to support most aquatic species. Levels below 4 mg/L are stressful to the majority of aquatic animals, so biodiversity will be affected. Water containing less than 2 mg/L dissolved oxygen will not support aerobic aquatic life.

The ability to quantify the amount of dissolved oxygen in a water source also has alternative methods, and many relevant practical applications. Some of these are explored here.

Dissolved oxygen and temperature can also be measured using a handheld LabQuest monitor with dissolved oxygen and temperature probes. For dissolved oxygen, plug the probe into channel 1. Units should be in mg/L. Submerge the probe into the water sample, circulating the probe slowly through the sample to avoid consuming oxygen in a localized area. When the readings appear to stabilize, record the value.

Most fish require moderate to good levels of dissolved oxygen in their habitats to thrive and reproduce. For fish farms, which may occupy man-made or natural lakes or streams, being able to test dissolved oxygen levels can help farm managers to choose a good initial set-up site, or to keep track of the health of their pools or streams.

Monitoring dissolved oxygen can also be useful for habitat management and conservation. If a lake or river region contains protected or endangered flora or fauna, monitoring of dissolved oxygen levels can give an indication of the health of the ecosystem. If levels change rapidly, this could indicate danger for the protected species, and may indicate that a management intervention strategy should be implemented.

The United States Environmental Protection Agency, the EPA, suggests a number of measures to correct dissolved oxygen levels in ecosystems. These include correct and minimal use of fertilizers, proper wastewater treatment, not discharging sewage from boats, and preserving adjoining rivers, streams, and wetlands. Reducing nitrogen oxides by minimizing electricity and automobile use and choosing more efficient boat engines can also help to maintain appropriate dissolved oxygen levels in water resources.

You've just watched JoVE's introduction to measuring dissolved oxygen in surface waters. You should now understand the principles behind dissolved oxygen measurement, how to quantify dissolved oxygen in your own water samples, and how to interpret your findings and their implications for the environment. Thanks for watching!

Subscription Required. Please recommend JoVE to your librarian.

Results

A dissolved oxygen level of 6 mg/L is sufficient for most aquatic species. Dissolved oxygen levels below 4 mg/L are stressful to most aquatic animals. Dissolved oxygen levels below 2 mg/L will not support aerobic aquatic life (Figure 5).

The maximum amount of oxygen that can be dissolved in water varies by temperature (Table 1).

DO measurements in mg/L are converted to % saturation using water temperature and the conversion chart below (Figure 6).

DISSOLVED OXYGEN LEVELS (% SATURATION)
Excellent: 91 – 110
Good: 71 – 90
Fair: 51 – 70
Poor: < 50

Figure 5a
Figure 5. DO measurements are converted to % saturation using the water’s temperature. The water’s temperature on the top horizontal axis and the measured DO value on the bottom horizontal axis. Use a ruler to draw a line between the two values and record where the line meets the middle diagonal axis for % saturation.

Figure 5
Figure 6. A dissolved oxygen level of 6 mg/L is sufficient for most aquatic species. Dissolved oxygen levels below 4 mg/L are stressful to most aquatic animals. Dissolved oxygen levels below 2 mg/L will not support fish and below 1 mg/L will not support most species.

Temp. (°C) DO (mg/L) Temp. (°C) DO (mg/L) Temp.(°C) DO (mg/L) Temp.(°C) DO (mg/L)
0 14.60 11 11.01 22 8.72 33 7.16
1 14.19 12 10.76 23 8.56 34 7.16
2 13.81 13 10.52 24 8.40 35 6.93
3 13.44 14 10.29 25 8.24 36 6.82
4 13.09 15 10.07 26 8.09 37 6.71
5 12.75 16 9.85 27 7.95 38 6.61
6 12.43 17 9.65 28 7.81 39 6.51
7 12.12 18 9.45 29 7.67 40 6.41
8 11.83 19 9.26 30 7.54 41 6.41
9 11.55 20 9.07 31 7.41 42 6.22
10 11.27 21 8.90 32 7.28 43 6.13

Table 1. Maximum amounts of oxygen that can be dissolved in water by temperature.

Subscription Required. Please recommend JoVE to your librarian.

Applications and Summary

Slow-moving rivers are particularly vulnerable to low DO levels, and in extreme cases, these DO levels can lead to hypoxic conditions, creating “dead zones” where aerobic life is no longer supported by a body of water (Figure 7). Once plants and animals die-off, the build-up of sediment that occurs can also raise the riverbed, allowing plants to colonize over the water and could lead to the loss of the river all together (Figure 8). Surface waters at higher altitudes are also more vulnerable to low DO levels, as atmospheric pressure decreases with increasing altitude, and less oxygen gas is suspended in the water.

Low DO levels support life forms considered unappealing or unfit for human use, including leeches and aquatic worms (Oligochaeta).

Figure 6
Figure 7. Map of dissolved oxygen concentrations across the Louisiana shelf showing the dead zone region.

Figure 7
Figure 8.  Photograph of the Caspian Sea showing severe eutrophication in the north end.

Subscription Required. Please recommend JoVE to your librarian.

Transcript

Tags

Dissolved Oxygen Surface Water Azide-Winkler Titration Method Aerobic Life Water Ecosystems Gaseous Oxygen Water Quality Organisms Sodium Thiosulfate Iodine Titration Oxygen Concentration Video Demonstration Eutrophication Excess Nutrients Algal Blooms Hypoxia

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter