Equipment used during data acquisition
Eye tracker
The eye tracker used in the current protocol is an EyeLink II system (SR Research Ltd; Mississauga, Ontario, Canada). This head-mounted, video-based eye tracker records eye position in X, Y-coordinate frame at a sampling rate of either 500 or 250 Hz, with a spatial resolution of < 0.1°. One camera is used to monitor head position by sending infrared markers to sensors placed on the four corners of the display monitor that is viewed by the participants. Two additional cameras are mounted on the headband situated below each of the eyes, and infrared illuminators are used to note the pupil and corneal reflections. Eye position may be based on pupil and corneal reflections, or based on the pupil only. The padded headband of the eye tracker can be adjusted in two planes to comfortably fit the head size of an adult participant. Most eyeglasses and contact lenses can be accommodated by the eye tracker.
Computers
Two PCs are used to support eye movement recording. One computer serves as the display computer, which presents the calibration screens, necessary task instructions and the images used in the experimental paradigm to the participants. The display computer details the data collection parameters that are then governed by the second, host computer. The host computer calculates real-time gaze position and records the eye movement data for later analysis, as well as any button press or keyboard responses made the participant. Participant setup and operations of the eye tracker are performed via the host PC.
Software
In this protocol, the timing and order by which experimental stimuli are to be presented to the participants, and the manner in which eye position is to be collected by the host PC are programmed through Experiment Builder, a software program specifically developed by SR Research Ltd to interface with the eye tracker host computer. However, stimulus presentation can also be conducted through other software programs (e.g., Presentation, Neurobehavioral Systems; Albany, CA). Conversion of the eye movement data to a series of fixation and saccade events that are time-locked to stimulus presentation (or another external event) is achieved through the host computer and can be interrogated with Data Viewer, a software program developed by SR Research Ltd; however, again, other programs can be used to derive the required eye movement measures. Here, the detection of fixations and saccades are dependent on an online parser, which separates raw eye movement samples into meaningful states (saccades, blinks and fixations). If the velocity of two successive eye movement samples exceeds 22 degrees per second over a distance of 0.1°, the samples are labeled as a saccade. If the pupil is missing for 3 or more samples, the eye activity is marked as a blink within the data stream. Non-saccade and non-blink activity are considered fixations.
Eye tracking procedures.
Below, we detail the procedures for obtaining eye movement recordings for each participant.
- Consent. Prior to participant setup, participants are shown the eye tracker headband. The experimenter explains to the participants that head and eye positions are monitored through the cameras that are contained on the headband.
- For a given experimental paradigm, participants are seated a fixed distance from the monitor to maintain the same visual angle across participants.
- Eye tracker camera setup. The eye tracker helmet is adjusted so that the helmet is snug and unlikely to move but not uncomfortable around the head. The helmet is further adjusted so that the head camera can send infrared illumination to the external markers on the display monitor. Each of the eye cameras are situated on individual rods that extend from the helmet which allow for adjustment in all axes. The eye cameras are positioned just under and slightly away from each eye without obstructing the participant s view of the display monitor (see Figure 1). The cameras are focused to get a clear and stable image of the pupil and corneal reflections. Status panels on the host computer indicate whether pupil and corneal reflections are being acquired. The illumination threshold can be adjusted to obtain the most stable recording of the pupil and corneal reflections. The experimenter then selects the appropriate experimental paradigm, and designates a filename for the ensuing eye movement recordings.

Figure 1. Example of a head-mounted video-based eye tracker (left) and the display and host PCs (right). Note that the display monitor in front of the participant shows the location of the pupil (blue dot with crosshair) and corneal reflection (yellow dot with crosshair) to aid in camera setup.
- Calibration. To obtain accurate recordings of the eye position on the display monitor, a calibration procedure is initiated following camera setup. During the calibration procedure, the participants are instructed to look at a series of targets that appear at various locations on the display. Typically, nine target locations are used, but calibration can be performed with as few as three target locations. From these nine recorded locations, eye position at any point on the screen can be interpolated.
- Validation. Following calibration, a validation procedure is used to check the accuracy of the eye movement recording. The same nine target locations are provided to the participant to fixate, and the difference is computed between the current fixation position and the previously recorded fixation position. If the average accuracy for recording of position for one (or both) eyes exceeds acceptable levels (average error < 0.5° and maximum error of any point < 1.0°), calibration and validation procedures are repeated. Following acceptance of the accuracy levels, the experimenter can determine if eye movement recording should be monocular or binocular. In the case of monocular recording, the experimenter can determine from which eye data is to be recorded, or the host PC can automatically select the eye with the lower average error and the lower maximum error. While calibration and validation can occur with slight head movement, it is advantageous to have participants sit as still as possible. Participants are also instructed not to anticipate the upcoming locations of targets, but rather to move to, and fixate deliberately on, the targets only when they appear and to stay fixated on the target until it disappears.
- Experimental Paradigm. Instructions particular to a given paradigm are presented to the participant (e.g., "Please freely view each of the following images."), and data recording is initiated for the session.
- Drift correction. Prior to the onset of each experimental stimulus, a drift correction can be performed by having the participants look at a central fixation target while pressing a button on a joypad or keyboard to accept the fixation position. When drift correction is employed, a trial will not begin until the participant successfully fixates on the central fixation region within 2.0° of the center target. If the participant consistently fixates greater than 2.0°, the participant must again undergo calibration and validation procedures. Any difference less than 2.0° between the recorded eye position and the initial fixation position obtained during the calibration/validation recordings is then noted as error and accounted for in the data.
- Stimulus presentation. Eye position, including fixation and saccade events, is recorded following drift correction procedures for each stimulus presentation. The experimenter can monitor the accuracy of the recordings online via inspection of the host computer.
- Following the eye movement recording session, measures that characterize the eye movement scanning patterns for different types of images (e.g. novel, repeated) can be derived with a variety of software packages, such as SR Research Ltd s Data Viewer. In addition, viewing to specific regions of a stimulus (e.g. unaltered, manipulated) can be characterized by analyzing eye movements with respect to experimenter-drawn regions of interest that are created for each image either at the paradigm programming phase or after data collection.
- Participants are debriefed regarding the purpose of the experiment at the conclusion of the session.
Representative Results
Multiple measures can be derived from the eye movement recordings, including measures that describe overall viewing to the image (including the characteristics of each fixation/saccade), and measures that describe the pattern of viewing that has been directed to a particular region of interest within an image 3. Measures of overall viewing to an image may include (but are not limited to): the number of fixations and the number of saccades made to the image, the average duration of each fixation, and the total amount of viewing time that was spent fixating on the image. Measures that describe the pattern of viewing to a particular region of interest may include (but are not limited to): the number of fixations made to the region of interest, the amount of time spent within a region of interest, and the number of transitions made into/out of a region of interest. Further, measures may be derived from the eye movement recordings that outline the timing by which (i.e., how early) a particular eye movement event has occurred, such as when, following stimulus onset, the eyes fixate on a specific region of interest, when the first saccade is made on an image, and the entropy (constraint/randomness) inherent in the sequence of eye movement patterns.
For any given image, eye movement measures can detail where the eyes were fixated, when and for how long. To obtain an index of memory, we can give viewers different types or amounts of exposure to distinct sets of images, and then compare viewing patterns across those sets and across participants. For instance, to probe memory for repetition of an image, scanning patterns can be contrasted between novel images and images that have been viewed multiple times throughout a testing session. Viewing images repeatedly throughout a testing session results in a decrease in overall viewing of the image 2, 4-5, 8. This can be seen in Figure 2. In this representative result from Riggs et al. 11, participants viewed novel pictures of faces once in each of five testing blocks; with increasing exposure, there was a decrease in the amount of fixations that viewers make to the faces. To probe memory for particular details of an image, scanning patterns can be contrasted between images that have been repeatedly viewed in their original, unaltered form (repeated images) and images that have similarly been viewed repeatedly throughout a testing session, but a change has been introduced to some element within a scene during the final exposure (manipulated images). In such cases, scanning patterns are attracted differentially to the region that has been altered within a manipulated image compared to the same, unaltered region of repeated images 2-3, 7-8. However, such eye movement indices of memory are not present in certain populations, such as when healthy older adults and patients with amnesia due to medial temporal lobe damage are assessed for their memory of the spatial relations among objects in scenes, as outlined in Figure 3 2, 8. Therefore, findings from eye movement monitoring can be used to contrast memory among groups of participants with differing neuropsychological status 2-3, 8-10.

Figure 2. Eye movements reveal memory for repetition. In this representative result from our laboratory [11], participants viewed faces across 5 study blocks; as the number of viewings increased (from 1-5), the number of fixations to the faces decreased.

Figure 3. Eye movements reveal memory for changed details. Younger adults [2 (Experiments 1, 2), 8 (Free Viewing Condition)] directed a greater proportion of their total eye fixations to a critical region in a manipulated image that has undergone a change from a prior viewing compared to when the region has not undergone a change, as in novel and repeated images. Such effects of memory were absent in healthy older adults [8 (Free Viewing Condition], and in amnesic patients [2].