Immunofluorescence Microscopy for the Analysis of DNA Double-Strand Breaks

Published: July 31, 2023

Abstract

Source: Popp, H. D., et al. Immunofluorescence Microscopy of γH2AX and 53BP1 for Analyzing the Formation and Repair of DNA Double-strand Breaks. J. Vis. Exp. (2017)

In this video, we describe the immunofluorescence microscopy technique to detect specific DNA damage response proteins localized at the sites of DNA double-strand breaks in human mononuclear cells. The proteins are recognized by specific primary antibodies, which in turn bind to fluorophore-tagged secondary antibodies that fluoresce during microscopic visualization, enabling visualization of the proteins as distinct fluorescent foci within the cell nuclei.

Protocol

All procedures involving human participants have been performed in compliance with the institutional, national, and international guidelines for human welfare and have been reviewed by the local institutional review board.

1. Preparation of the cytospins

  1. Prepare two cytospins with mononuclear cells of the patient samples (i.e., one cytospin for γH2AX immunofluorescence staining and one cytospin for γH2AX and 53BP1 combined immunofluorescence staining) by centrifugation (300 x g, 10 min) of 1.0 x 105 cells for each preparation (Figure 1 and 2).

2. γH2AX and 53BP1 Immunofluorescence Staining

  1. Fixation and permeabilization: Fix the cells with 200 µL of 4% PFA for 10 min. After fixation, wash the cells gently three times with 30 mL of PBS for 5 min each on a lab shaker. Then permeabilize the cells with 200 µL of 0.1% Octoxinol 9 for 10 min. Wash the cells gently three times with 30 mL of 5% blocking solution for 5 min each on a lab shaker. Block the cells in 30 mL of fresh 5% blocking solution for 1 h.
  2. Incubation with antibodies
    1. Incubate one preparation of the cells with a mouse monoclonal anti-γH2AX antibody (1:500) and the other preparation of the cells with a mouse monoclonal anti-γH2AX antibody (1:500) and a polyclonal rabbit anti-53BP1 antibody (1:500) overnight at 4 °C.
    2. After incubation wash the cells gently 3 times with 30 mL of 2% blocking solution for each 5 min on a lab shaker.
    3. Remove the blocking solution and incubate the first preparation of the cells with an Alexa488-conjugated goat anti-mouse secondary antibody (1:500) and the second preparation of the cells with an Alexa488-conjugated goat anti-mouse secondary antibody (1:500) and an Alexa555-conjugated donkey anti-rabbit secondary antibody (1:500) for 1 h at room temperature.
  3. Mounting medium: Put the slide with the cells in a bowl and wash the cells gently three times with 30 mL of PBS for each 5 min on a lab shaker. Remove the PBS and mount the cells with a mounting medium containing 4,6-diamidino-2-phenylindole. Cautiously put a coverslip on top of the mounting medium so that no air bubbles are embedded. Wait for at least 3 h for the hardening of the mounting medium before analyzing the cells by fluorescence microscopy.

3. Analysis of γH2AX and 53BP1 Foci

  1. Fluorescence microscopy: Analyze the γH2AX and 53BP1 foci in the cell nuclei with a fluorescence microscope equipped with filters for DAPI, Alexa 488, and Cy3 during imaging at a 100X objective magnification. Record images with a camera and process the images with appropriate imaging software.

Representative Results

Figure 1
Figure 1: Device for preparing the cytospins.

Figure 2
Figure 2: Preparation of the cytospins. Two cytospins of each sample are prepared by centrifugation of 1.0 x 105 cells at 300 x g for 10 min. One cytospin is used for γH2AX immunofluorescence staining, and another cytospin is utilized for combined γH2AX and 53BP1 immunofluorescence staining.

Disclosures

The authors have nothing to disclose.

Materials

Diagnostic microscope slidesThermo ScientificER-203B-CE24Microscope slides
Megafuge 1.0 RHeraeus75003060Tabletop centrifuge
Cytospin device
LidHeraeus76003422Lid for working without micro-tubes
Cyto containerHeraeus75003416Cyto container with 2 conical bores
Clip carrierHeraeus75003414Carrier for holding a cyto container and a slide
Support insertHeraeus75003417Support insert for holding a clip carrier
ParaformaldehydeSigma-AldrichP6148Fixation agent
Phosphate-buffered salineSigma-AldrichD8537Balanced salt solution
ChemiblockerMerck Millipore2170Blocking agent
Mouse monoclonal anti-γH2AX antibody (JBW301)Merck Millipore05-636Primary antibody for detection of γH2AX
Polyclonal rabbit anti-53BP1 antibody (NB100-304)Novus BiologicalsNB100-304Primary antibody for detection of 53BP1
Alexa Fluor 488-conjugated goat anti-mouse antibodyInvitrogenA-11001Secondary antibody
Alexa Fluor 555-conjugated donkey anti-rabbit antibodyInvitrogenA-31572 Secondary antibody
Vectashield mounting mediumVector LaboratoriesH-1200Contains DAPI for staining of DNA
Axio Scope.A1Zeiss490035Fluorescence microscope
Cool Cube 1 CCD cameraMetasystemsH-0310-010-MSCamera system for digital recording
Isis softwareMetasystemsNot applicableMicroscope software

Tags

Immunofluorescence Microscopy for the Analysis of DNA Double-Strand Breaks

Play Video

Cite This Article
Immunofluorescence Microscopy for the Analysis of DNA Double-Strand Breaks. J. Vis. Exp. (Pending Publication), e21465, doi: (2025).

View Video