Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism.
J Cataract Refract Surg
PUBLISHED: 08-29-2014
Show Abstract
Hide Abstract
To evaluate the influence of posterior corneal astigmatism on total corneal astigmatism in patients with 1.00 diopter (D) or more of corneal astigmatism.
Related JoVE Video
Influence of intraocular lens haptic design on refractive error.
J Cataract Refract Surg
PUBLISHED: 08-20-2014
Show Abstract
Hide Abstract
To assess the influence of intraocular (IOL) haptic design on the refraction prediction error in patients having cataract surgery.
Related JoVE Video
Comparison of Anterior Segment Measurements with Scheimpflug/Placido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts.
J Ophthalmol
PUBLISHED: 08-15-2014
Show Abstract
Hide Abstract
Purpose. To assess the consistency of anterior segment measurements obtained using a Sirius Scheimpflug/Placido photography-based topography system (CSO, Italy) and IOLMaster partial coherence interferometry (Carl Zeiss Meditec, Germany) in eyes with cataracts. Methods. A total of 90 eyes of 90 patients were included in this prospective study. The anterior chamber depth (ACD), keratometry (K), corneal astigmatism axis, and white to white (WTW) values were randomly measured three times with Sirius and IOLMaster. Concordance between them was assessed by calculating 95% limits of agreement (LoA). Results. The ACD and K taken with the Sirius were statistically significantly higher than that taken with the IOLMaster; however, the Sirius significantly underestimated the WTW values compared with the IOLMaster. Good agreement was found for Km and ACD measurements, with 95% LoA of -0.20 to 0.54?mm and -0.16 to 0.34?mm, respectively. Poor agreement was observed for astigmatism axis and WTW measurements, as the 95% LoA was -23.96 to 23.36° and -1.15 to 0.37?mm, respectively. Conclusion. With the exception of astigmatism axis and WTW, anterior segment measurements taken by Sirius and IOLMaster devices showed good agreement and may be used interchangeably in patients with cataracts.
Related JoVE Video
Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery.
J Cataract Refract Surg
PUBLISHED: 05-27-2014
Show Abstract
Hide Abstract
To evaluate whether the refractive changes induced by excimer laser surgery can be accurately measured by corneal ray tracing performed by a combined rotating Scheimpflug camera-Placido-disk corneal topographer (Sirius).
Related JoVE Video
Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster.
Br J Ophthalmol
PUBLISHED: 05-02-2014
Show Abstract
Hide Abstract
To assess the reliability of ocular component measurements with a new optical biometry device (AL-Scan; Nidek) and compare these measurements with those of the IOLMaster (Carl Zeiss Meditec) in patients with cataract.
Related JoVE Video
Comparison and evaluation of central corneal thickness using 2 new noncontact specular microscopes and conventional pachymetry devices.
Cornea
PUBLISHED: 04-05-2014
Show Abstract
Hide Abstract
The aim of this study was to evaluate the repeatability of central corneal thickness (CCT) measurements in normal eyes using 2 new noncontact specular microscopes (NCSMs) EM-3000 (Tomey, Japan) and SP-02 (CSO, Italy) and to compare the results with those obtained from an SP-3000P NCSM (Topcon, Japan) and ultrasound pachymetry (USP).
Related JoVE Video
Related JoVE Video
Central and midperipheral corneal thickness measured with Scheimpflug imaging and optical coherence tomography.
PLoS ONE
PUBLISHED: 01-01-2014
Show Abstract
Hide Abstract
To compare corneal thickness measurements using Pentacam (Oculus, Germany), Sirius (CSO, Italy), Galilei (Ziemer, Switzerland), and RTVue-100 OCT (Optovue Inc., USA).
Related JoVE Video
Retinal nerve fiber layer thickness changes in Parkinson disease: a meta-analysis.
PLoS ONE
PUBLISHED: 01-01-2014
Show Abstract
Hide Abstract
Parkinson disease (PD) is a neurodegenerative process that leads to a selective loss of dopaminergic neurons, mainly in the basal ganglia of the brain. Numerous studies have analyzed the ability of optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) thickness abnormalities and changes in PD, but the results have not always been consistent. Therefore, we carried out a meta-analysis to evaluate the RNFL thickness measured with OCT in PD.
Related JoVE Video
A new slant on toric intraocular lens power calculation.
J Refract Surg
PUBLISHED: 12-19-2013
Show Abstract
Hide Abstract
The AcrySof Toric intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX) is designed to correct corneal astigmatism ranging from 0.67 to 4.11 diopters (D). The authors reviewed the clinical outcomes of this IOL and investigated possible improvements of the online calculator provided by the manufacturer.
Related JoVE Video
Comparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography.
J. Glaucoma
PUBLISHED: 12-16-2013
Show Abstract
Hide Abstract
To compare the measurements of the optic nerve head (ONH) parameters provided by time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT).
Related JoVE Video
Retinal function and neural conduction along the visual pathways in affected and unaffected carriers with Lebers hereditary optic neuropathy.
Invest. Ophthalmol. Vis. Sci.
PUBLISHED: 09-28-2013
Show Abstract
Hide Abstract
We assessed retinal ganglion cell (RGC) function, and established a correlation between the neural conduction along the visual pathways and the retinal involvement in Lebers hereditary optic neuropathy (LHON).
Related JoVE Video
Intraocular lens power calculation by ray-tracing after myopic excimer laser surgery.
Am. J. Ophthalmol.
PUBLISHED: 05-18-2013
Show Abstract
Hide Abstract
To investigate the refractive outcomes of intraocular lens (IOL) power calculation by ray-tracing after myopic excimer laser surgery.
Related JoVE Video
Laser-assisted subepithelial keratectomy versus epipolis laser in situ keratomileusis for myopia: a meta-analysis of clinical outcomes.
Clin. Experiment. Ophthalmol.
PUBLISHED: 04-06-2013
Show Abstract
Hide Abstract
To identify possible differences between laser-assisted subepithelial keratectomy and epipolis laser in situ keratomileusis for myopia.
Related JoVE Video
Surgical management of malignant glaucoma with white cataract in nanophthalmos.
J Cataract Refract Surg
PUBLISHED: 03-31-2013
Show Abstract
Hide Abstract
We present a 49-year-old woman with nanophthalmos, white cataract, and malignant glaucoma in her left eye. The corrected distance visual acuity (CDVA) in that eye was hand motion, and the intraocular pressure (IOP) fluctuated between 28 mm Hg and 45 mm Hg with antiglaucoma medications. An unsutured sclerectomy combined with zonulectomy, hyaloidectomy, and anterior vitrectomy was performed. At 6 months postoperatively, the IOP was maintained at 12 mm Hg, the anterior chamber was deep, and the Snellen CDVA was 20/80. No intraoperative or postoperative complications were observed. The outcome in this case suggests that sclerectomy combined with phacoemulsification, zonulectomy, hyaloidectomy, and anterior vitrectomy is effective for the management of nanophthalmic patients with white cataract and malignant glaucoma.
Related JoVE Video
Repeatability, reproducibility, and agreement of corneal power measurements obtained with a new corneal topographer.
J Cataract Refract Surg
PUBLISHED: 03-27-2013
Show Abstract
Hide Abstract
To study the repeatability and reproducibility of corneal power measurements obtained with a new corneal topographer (Keratograph 4) and assess their agreement with those obtained by a rotating Scheimpflug camera (Pentacam HR) and an automated keratometer (IOLMaster).
Related JoVE Video
Scheimpflug analysis of corneal power changes after myopic excimer laser surgery.
J Cataract Refract Surg
PUBLISHED: 03-07-2013
Show Abstract
Hide Abstract
To assess the ability of corneal power measurements by a rotating Scheimpflug camera to measure the refractive change induced by myopic excimer laser surgery.
Related JoVE Video
A Comparison between Scheimpflug imaging and optical coherence tomography in measuring corneal thickness.
Ophthalmology
PUBLISHED: 02-17-2013
Show Abstract
Hide Abstract
To assess the repeatability and reproducibility of 3 rotating Scheimpflug cameras, the Pentacam (Oculus, Wetzlar, Germany), Sirius (Costruzione Strumenti Oftalmici, Florence, Italy), and Galilei (Ziemer, Biel, Switzerland), and 1 Fourier-domain optical coherence tomography (FD-OCT) system, the RTvue-100 OCT (Optovue Inc., Fremont, CA), in measuring corneal thickness.
Related JoVE Video
Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera.
J Cataract Refract Surg
PUBLISHED: 02-09-2013
Show Abstract
Hide Abstract
To assess the accuracy of corneal power measurements provided by a Scheimpflug camera (Pentacam HR) for intraocular lens (IOL) power calculation in unoperated eyes and compare the results with those of simulated keratometry (SimK) performed with a Placido-disk corneal topographer (Keratron).
Related JoVE Video
Anterior chamber and aqueous depth measurement in pseudophakic eyes: agreement between ultrasound biometry and scheimpflug imaging.
J Refract Surg
PUBLISHED: 02-06-2013
Show Abstract
Hide Abstract
To compare anterior chamber depth (ACD) and aqueous depth (AQD) measurements provided by a Scheimpflug camera combined with corneal topography to those obtained by immersion ultrasound (US) biometry when assessing the distance between the cornea and intraocular lens (IOL) in pseudophakic patients.
Related JoVE Video
Evaluation of corneal thickness using a Scheimpflug-Placido disk corneal analyzer and comparison with ultrasound pachymetry in eyes after laser in situ keratomileusis.
J Cataract Refract Surg
PUBLISHED: 01-26-2013
Show Abstract
Hide Abstract
To evaluate the repeatability and reproducibility of corneal thickness measurements in post-laser in situ keratomileusis (LASIK) eyes using a rotating Scheimpflug camera combined with a Placido disk corneal topographer (Sirius) and compare the results with those of ultrasound (US) pachymetry.
Related JoVE Video
Accuracy of a dual Scheimpflug analyzer and a corneal topography system for intraocular lens power calculation in unoperated eyes.
J Cataract Refract Surg
PUBLISHED: 03-11-2011
Show Abstract
Hide Abstract
To evaluate the accuracy of the corneal power measurements by a dual Scheimpflug analyzer (Galilei) and a corneal topography system (Keratron) for intraocular lens (IOL) power calculation in unoperated eyes.
Related JoVE Video
The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT.
Br J Ophthalmol
PUBLISHED: 02-24-2011
Show Abstract
Hide Abstract
To evaluate the influence of axial length on measurements of the retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) parameters in healthy subjects.
Related JoVE Video
Retinal nerve fiber layer thickness in dominant optic atrophy measurements by optical coherence tomography and correlation with age.
Ophthalmology
PUBLISHED: 02-15-2011
Show Abstract
Hide Abstract
To measure the retinal nerve fiber layer (RNFL) thickness by means of optical coherence tomography (OCT) in patients with dominant optic atrophy (DOA).
Related JoVE Video
Spectral-domain optical coherence tomography for the diagnosis and follow-up of glaucoma.
Curr Opin Ophthalmol
PUBLISHED: 02-11-2011
Show Abstract
Hide Abstract
As spectral-domain optical coherence tomography (SD-OCT) progressively replaces time-domain OCT (TD-OCT) in the clinical and research setting, several commercially available instruments and new software upgrades for glaucoma diagnosis and progression analysis have been developed. Over the last year, several studies have been performed to assess the diagnostic performance of most of these instruments necessitating a review of their findings.
Related JoVE Video
Repeatability of optic nerve head parameters measured by spectral-domain OCT in healthy eyes.
Ophthalmic Surg Lasers Imaging
PUBLISHED: 02-04-2011
Show Abstract
Hide Abstract
To evaluate the repeatability of optic nerve head (ONH) measurements by spectral-domain optical coherence tomography.
Related JoVE Video
Repeatability of automatic measurements performed by a dual Scheimpflug analyzer in unoperated and post-refractive surgery eyes.
J Cataract Refract Surg
PUBLISHED: 01-19-2011
Show Abstract
Hide Abstract
To assess the repeatability of the anterior segment measurements performed with a dual Scheimpflug analyzer (Galilei) in unoperated and post-refractive surgery eyes.
Related JoVE Video
Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer.
J Cataract Refract Surg
PUBLISHED: 01-17-2011
Show Abstract
Hide Abstract
To compare the anterior segment measurements provided by 3 Scheimpflug tomographers and a Placido corneal topographer.
Related JoVE Video
Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography.
J Cataract Refract Surg
PUBLISHED: 01-13-2011
Show Abstract
Hide Abstract
To assess the repeatability of anterior segment measurements performed by a Scheimpflug camera combined with Placido corneal topography (Sirius) in unoperated, post-refractive surgery, and keratoconus eyes.
Related JoVE Video
Anterior chamber depth measurement in pseudophakic eyes: a comparison of Pentacam and ultrasound.
J Refract Surg
PUBLISHED: 05-19-2010
Show Abstract
Hide Abstract
To compare the anterior chamber depth (ACD) measurements of a Scheimpflug camera (Pentacam, Oculus Optikgeräte GmbH) and immersion ultrasound biometry (UltraScan Imaging System, Alcon Laboratories) in pseudophakic eyes.
Related JoVE Video
OPA1 mutations associated with dominant optic atrophy influence optic nerve head size.
Ophthalmology
PUBLISHED: 04-24-2010
Show Abstract
Hide Abstract
To analyze the influence of OPA1 gene mutations on the optic nerve head (ONH) morphology in patients with dominant optic atrophy (DOA).
Related JoVE Video
Comparison of 2 laser instruments for measuring axial length.
J Cataract Refract Surg
PUBLISHED: 04-06-2010
Show Abstract
Hide Abstract
To compare axial length (AL), anterior chamber depth (ACD), and keratometric (K) measurements of 2 laser biometers.
Related JoVE Video
Intraocular lens power calculation after myopic excimer laser surgery: clinical comparison of published methods.
J Cataract Refract Surg
PUBLISHED: 02-19-2010
Show Abstract
Hide Abstract
To compare results of intraocular lens (IOL) power calculation methods after myopic excimer laser surgery.
Related JoVE Video
Clinical relevance of radius of curvature error in corneal power measurements after excimer laser surgery.
J Cataract Refract Surg
PUBLISHED: 02-02-2010
Show Abstract
Hide Abstract
To compare central and paracentral corneal curvature measurements after myopic excimer laser surgery performed using a large optical zone (OZ) (6.5mm).
Related JoVE Video
Agreement between Pentacam and videokeratography in corneal power assessment.
J Refract Surg
PUBLISHED: 07-17-2009
Show Abstract
Hide Abstract
To investigate agreement between a rotating Scheimpflug camera (Pentacam, Oculus Optikgeräte GmbH) and two corneal topographers (TMS-2 Topography System, Tomey; and Keratron Scout, Optikon 2000 SpA) in measuring the corneal power of normal eyes.
Related JoVE Video
Association of optic disc size with development and prognosis of Lebers hereditary optic neuropathy.
Invest. Ophthalmol. Vis. Sci.
PUBLISHED: 04-11-2009
Show Abstract
Hide Abstract
To study the optic nerve head (ONH) morphology of patients with Lebers hereditary optic neuropathy (LHON) in a large family from Brazil carrying the 11778/ND4 mutation and in a case series of unrelated Italian families bearing different mitochondrial DNA (mtDNA) pathogenic mutations.
Related JoVE Video
Visual system involvement in patients with Friedreichs ataxia.
Brain
PUBLISHED: 03-11-2009
Show Abstract
Hide Abstract
Optic neuropathy is common in mitochondrial disorders, but poorly characterized in Friedreichs ataxia (FRDA), a recessive condition caused by lack of the mitochondrial protein frataxin. We investigated 26 molecularly confirmed FRDA patients by studying both anterior and posterior sections of the visual pathway using a new, integrated approach. This included visual field testing and optical coherence tomography (OCT), pattern visual evoked potentials (P-VEPs) and diffusion-weighted imaging. The latter was used to study optic radiation by calculating water apparent diffusion coefficients (ADC). All patients suffered optic nerve involvement with their disorder. Different patterns of visual field defects were observed and a variably reduced retinal nerve fiber layer thickness was seen by OCT in all cases. P-VEPs were abnormal in approximately half of the patients. Decreased visual acuity and temporal optic disc pallor were present in advanced stages of the disease, but only five patients were symptomatic. Two of these patients suffered a sudden loss of central vision, mimicking Lebers hereditary optic neuropathy (LHON), and of the other three symptomatic patients two were noted to be compound heterozygotes. ADC values of optic radiations in patients were significantly higher than controls (P < 0.01). Retinal nerve fiber layer thickness at OCT and P-VEPs correlated with age at onset and ICARS total score. ADC values correlated with age at onset, disease duration, GAA triplet expansion size, ICARS total score and P-VEPs. Visual pathway involvement is found consistently in FRDA, being previously underestimated, and we here document that it also involves the optic radiations. Occasional LHON-like cases may occur. However, optic neuropathy in FRDA substantially differs from classic mitochondrial optic neuropathies implying a different pathophysiology of visual system degeneration in this mitochondrial disease.
Related JoVE Video
Agreement between stratus and visante optical coherence tomography systems in tear meniscus measurements.
Cornea
PUBLISHED: 01-23-2009
Show Abstract
Hide Abstract
To compare the tear meniscus height (TMH) measurements provided by the Stratus and Visante optical coherence tomography systems.
Related JoVE Video
Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation.
J Cataract Refract Surg
PUBLISHED: 01-09-2009
Show Abstract
Hide Abstract
To evaluate the accuracy of corneal power measurements by the Pentacam Scheimpflug system for intraocular lens (IOL) power calculation.
Related JoVE Video
Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetry.
J Cataract Refract Surg
Show Abstract
Hide Abstract
To assess the precision of corneal thickness measurements obtained by a new Scheimpflug camera combined with Placido-disk corneal topography (Sirius) and compare the measured values with those obtained by ultrasound (US) pachymetry.
Related JoVE Video
A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices.
PLoS ONE
Show Abstract
Hide Abstract
To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices.
Related JoVE Video
Use of a support vector machine for keratoconus and subclinical keratoconus detection by topographic and tomographic data.
Ophthalmology
Show Abstract
Hide Abstract
To define a new classification method for the diagnosis of keratoconus based on corneal measurements provided by a Scheimpflug camera combined with Placido corneal topography (Sirius, CSO, Florence, Italy).
Related JoVE Video
Retinal nerve fiber layer thickness variability in Leber hereditary optic neuropathy carriers.
Eur J Ophthalmol
Show Abstract
Hide Abstract
Purpose. Recent investigations suggested that unaffected carriers of Leber hereditary optic neuropathy (LHON) may show subclinical visual alterations. Structural changes have also been detected by optical coherence tomography (OCT), which revealed a temporal thickening of the retinal nerve fiber layer (RNFL). These changes may reflect compensatory effects such as mitochondria accumulation within the RNFL axons. This study aimed to investigate whether the RNFL of LHON carriers shows greater than expected thickness variations, which may reflect transient subclinical changes, over the course of years. Methods. Using Stratus OCT, the RNFL thickness was measured yearly from 2005 to 2008 in 24 Brazilian LHON carriers, all with homoplasmic 11778/ND4 mtDNA mutation. An Italian sample of 20 healthy subjects served as a control. Data were compared also to a previously published sample (n=59) of glaucomatous eyes. Results. The LHON carriers showed test-retest standard deviations that were larger than normal controls in the temporal (p=0.004), superior (p<0.0001), and inferior quadrants (p=0.019). Compared to the glaucoma cases, no statistical differences were observed. Conclusions. The RNFL thickness in LHON carriers, when measured at different time points, has higher variability than in normal subjects. Transitory RNFL swelling may be caused either by compensatory mechanisms (increased mitochondrial biogenesis) or by axonal stasis preceding decompensation of retinal ganglion cells. In both situations, these changes may represent the origin of the visual alterations previously detected in LHON carriers. Alternatively, increased variability of RNFL thickness may be influenced by the LHON microangiopathy, as retinal blood vessels contribute to the OCT RNFL thickness measurements.
Related JoVE Video
Scheimpflug camera measurement of anterior and posterior corneal curvature in eyes with previous radial keratotomy.
J Refract Surg
Show Abstract
Hide Abstract
To compare the anterior and posterior corneal curvature in eyes with previous radial keratotomy (RK) to normal unoperated eyes.
Related JoVE Video
Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes.
J Cataract Refract Surg
Show Abstract
Hide Abstract
To assess the accuracy of the corneal power measurements with a new Scheimpflug camera combined with Placido-disk corneal topography (Sirius) (combined Scheimpflug camera-topographer) for intraocular lens (IOL) power calculation in unoperated eyes and compare the results with those by a validated corneal topographer (Keratron) (validated topographer).
Related JoVE Video

What is Visualize?

JoVE Visualize is a tool created to match the last 5 years of PubMed publications to methods in JoVE's video library.

How does it work?

We use abstracts found on PubMed and match them to JoVE videos to create a list of 10 to 30 related methods videos.

Video X seems to be unrelated to Abstract Y...

In developing our video relationships, we compare around 5 million PubMed articles to our library of over 4,500 methods videos. In some cases the language used in the PubMed abstracts makes matching that content to a JoVE video difficult. In other cases, there happens not to be any content in our video library that is relevant to the topic of a given abstract. In these cases, our algorithms are trying their best to display videos with relevant content, which can sometimes result in matched videos with only a slight relation.