Simultaneous Phase Unwrapping and Removal of chemical Shift (SPURS) using Graph Cuts: Application in Quantitative Susceptibility Mapping.
IEEE Trans Med Imaging
PUBLISHED: 10-15-2014
Show Abstract
Hide Abstract
Quantitative Susceptibility Mapping (QSM) is a magnetic resonance imaging technique that reveals tissue magnetic susceptibility. It relies on having a high quality field map, typically acquired with a relatively long echo spacing and long final TE. Applications of QSM outside the brain require the removal of fat contributions to the total signal phase. However, current water/fat separation methods applied on typical data acquired for QSM suffer from three issues: inadequacy when using large echo spacing, over-smoothing of the field maps and high computational cost. In this paper, the general phase wrap and chemical shift problem is formulated using a single species fitting and is solved using graph cuts with conditional jump moves. This method is referred as Simultaneous Phase Unwrapping and Removal of chemical Shift (SPURS). The result from SPURS is then used as the initial guess for a voxel-wise Iterative Decomposition of water and fat with Echo Asymmetric and Least-squares estimation (IDEAL). The estimated three-dimensional field maps are used to compute Quantitative Susceptibility Maps (QSM) in body regions outside of the brain, such as the liver. Experimental results show substantial improvements in field map estimation, water/fat separation and reconstructed QSM compared to two existing water/fat separation methods on 1.5T and 3T magnetic resonance human data with long echo spacing and rapid field map variation.
Related JoVE Video
Multiple sclerosis lesion geometry in quantitative susceptibility mapping (QSM) and phase imaging.
J Magn Reson Imaging
PUBLISHED: 08-30-2014
Show Abstract
Hide Abstract
To demonstrate the phase and quantitative susceptibility mapping (QSM) patterns created by solid and shell spatial distributions of magnetic susceptibility in multiple sclerosis (MS) lesions.
Related JoVE Video
Quantitative mapping of cerebral metabolic rate of oxygen (CMRO2 ) using quantitative susceptibility mapping (QSM).
Magn Reson Med
PUBLISHED: 06-20-2014
Show Abstract
Hide Abstract
To quantitatively map cerebral metabolic rate of oxygen ( CMRO2) and oxygen extraction fraction ( OEF) in human brains using quantitative susceptibility mapping (QSM) and arterial spin labeling-measured cerebral blood flow (CBF) before and after caffeine vasoconstriction.
Related JoVE Video
Quantification of cerebral perfusion using dynamic quantitative susceptibility mapping.
Magn Reson Med
PUBLISHED: 03-27-2014
Show Abstract
Hide Abstract
The purpose of this study is to develop a dynamic quantitative susceptibility mapping (QSM) technique with sufficient temporal resolution to map contrast agent concentration in cerebral perfusion imaging.
Related JoVE Video
Joint estimation of chemical shift and quantitative susceptibility mapping (chemical QSM).
Magn Reson Med
PUBLISHED: 02-07-2014
Show Abstract
Hide Abstract
The purpose of this work is to address the unsolved problem of quantitative susceptibility mapping (QSM) of tissue with fat where both fat and susceptibility change the MR signal phase.
Related JoVE Video
Background field removal by solving the Laplacian boundary value problem.
NMR Biomed
PUBLISHED: 01-07-2014
Show Abstract
Hide Abstract
The removal of the background magnetic field is a critical step in generating phase images and quantitative susceptibility maps, which have recently been receiving increasing attention. Although it is known that the background field satisfies Laplace's equation, the boundary values of the background field for the region of interest have not been explicitly addressed in the existing methods, and they are not directly available from MRI measurements. In this paper, we assume simple boundary conditions and remove the background field by explicitly solving the boundary value problems of Laplace's or Poisson's equation. The proposed Laplacian boundary value (LBV) method for background field removal retains data near the boundary and is computationally efficient. Tests on a numerical phantom and an experimental phantom showed that LBV was more accurate than two existing methods.
Related JoVE Video
How accurate is MOLLI T1 mapping in vivo? Validation by spin echo methods.
PLoS ONE
PUBLISHED: 01-01-2014
Show Abstract
Hide Abstract
T1 mapping is a promising quantitative tool for assessing diffuse cardiomyopathies. The purpose of this study is to quantify in vivo accuracy of the Modified Look-Locker Inversion Recovery (MOLLI) cardiac T1 mapping sequence against the spin echo gold standard, which has not been done previously. T1 accuracy of MOLLI was determined by comparing with the gold standard inversion recovery spin echo sequence in the calf muscle, and with a rapid inversion recovery fast spin echo sequence in the heart. T1 values were obtained with both conventional MOLLI fitting and MOLLI fitting with inversion efficiency correction. In the calf (n = 6), conventional MOLLI fitting produced inconsistent T1 values with error ranging from 8.0% at 90° to 17.3% at 30°. Modified MOLLI fitting with inversion efficiency correction improved error to under 7.4% at all flip angles. In the heart (n = 5), modified MOLLI fitting with inversion correction reduced T1 error to 5.5% from 14.0% by conventional MOLLI fitting. This study shows that conventional MOLLI fitting can lead to significant in vivo T1 errors when not accounting for the lower adiabatic inversion efficiency often experienced in vivo.
Related JoVE Video
Self-gated free-breathing 3D coronary CINE imaging with simultaneous water and fat visualization.
PLoS ONE
PUBLISHED: 01-01-2014
Show Abstract
Hide Abstract
The aim of this study was to develop a novel technique for acquiring 3-dimensional (3D) coronary CINE magnetic resonance images with both water and fat visualization during free breathing and without external respiratory or cardiac gating. The implemented multi-echo hybrid 3D radial balanced Steady-State Free Precession (SSFP) sequence has an efficient data acquisition and is robust against motion. The k-space center along the slice encoding direction was repeatedly acquired to derive both respiratory and cardiac self-gating signals without an increase in scan time, enabling a free-breathing acquisition. The multi-echo acquisition allowed image reconstruction with water-fat separation, providing improved visualization of the coronary artery lumen. Ten healthy subjects were imaged successfully at 1.5 T, achieving a spatial resolution of 1.0 × 1.0 × 3.0 mm(3) and scan time of about 5 minutes. The proposed imaging technique provided coronary vessel depiction comparable to that obtained with conventional breath-hold imaging and navigator gated free-breathing imaging.
Related JoVE Video
Noise Effects In Various Quantitative Susceptibility Mapping Methods.
IEEE Trans Biomed Eng
PUBLISHED: 06-12-2013
Show Abstract
Hide Abstract
Various regularization methods have been proposed for single-orientation quantitative susceptibility mapping (QSM), which is an ill-posed magnetic field to susceptibility source inverse problem. Noise amplification, a major issue in inverse problems, manifests as streaking artifacts and quantification errors in QSM and has not been comparatively evaluated in these algorithms. In this paper, various QSM methods were systematically categorized for noise analysis. Six representative QSM methods were selected from four categories: two non-Bayesian methods with alteration or approximation of the dipole kernel to overcome the ill conditioning; four Bayesian methods using a general mathematical prior or a specific physical structure prior to select a unique solution, and using a data fidelity term with or without noise weighting. The effects of noise in these QSM methods were evaluated by reconstruction errors in simulation and image quality in 50 consecutive human subjects. Bayesian QSM methods with noise weighting consistently reduced root mean squared errors in numerical simulations and increased image quality scores in the human brain images, when compared to non-Bayesian methods and to corresponding Bayesian methods without noise weighting (p 0.001). In summary, noise effects in QSM can be reduced using Bayesian methods with proper noise weighting.
Related JoVE Video
An iterative spherical mean value method for background field removal in MRI.
Magn Reson Med
PUBLISHED: 05-22-2013
Show Abstract
Hide Abstract
The sophisticated harmonic artifact reduction for phase data (SHARP) method has been proposed for the removal of background field in MRI phase data. It relies on the spherical mean value (SMV) property of harmonic functions, and its accuracy depends on the radius of the sphere used for computing the SMV and truncation threshold needed for deconvolution. The goal of this study was to develop an alternative SMV-based background field removal method with reduced dependences on these parameters.
Related JoVE Video
Flow compensated quantitative susceptibility mapping for venous oxygenation imaging.
Magn Reson Med
PUBLISHED: 05-20-2013
Show Abstract
Hide Abstract
Venous blood oxygen saturation is an indicator of brain oxygen consumption and can be measured directly from quantitative susceptibility mapping (QSM) by deconvolving the MR phase signal. However, accurate estimation of the susceptibility of blood may be affected by flow induced phase in the presence of imaging gradient and the inhomogeneous susceptibility field gradient. The purpose of this study is to correct the flow induced error in QSM for improved venous oxygenation quantification.
Related JoVE Video
Direct coronary motion extraction from a 2D fat image navigator for prospectively gated coronary MR angiography.
Magn Reson Med
PUBLISHED: 01-25-2013
Show Abstract
Hide Abstract
PURPOSE: Direct 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. METHODS: The proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. RESULTS: Real-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P?
Related JoVE Video
Magnetic susceptibility anisotropy: cylindrical symmetry from macroscopically ordered anisotropic molecules and accuracy of MRI measurements using few orientations.
Neuroimage
PUBLISHED: 01-04-2013
Show Abstract
Hide Abstract
White matter is an essential component of the central nervous system and is of major concern in neurodegenerative diseases such as multiple sclerosis (MS). Recent MRI studies have explored the unique anisotropic magnetic properties of white matter using susceptibility tensor imaging. However, these measurements are inhibited in practice by the large number of different head orientations needed to accurately reconstruct the susceptibility tensor. Adding reasonable constraints reduces the number of model parameters and can help condition the tensor reconstruction from a small number of orientations. The macroscopic magnetic susceptibility is decomposed as a sum of molecular magnetic polarizabilities, demonstrating that macroscopic order in molecular arrangement is essential to the existence of and symmetry in susceptibility anisotropy and cylindrical symmetry is a natural outcome of an ordered molecular arrangement. Noise propagation in the susceptibility tensor reconstruction is analyzed through its condition number, showing that the tensor reconstruction is highly susceptible to the distribution of acquired subject orientations and to the tensor symmetry properties, with a substantial over- or under-estimation of susceptibility anisotropy in fiber directions not favorably oriented with respect to the acquired orientations. It was found that a careful acquisition of three non-coplanar orientations and the use of cylindrical symmetry guided by diffusion tensor imaging allowed reasonable estimation of magnetic susceptibility anisotropy in certain major white matter tracts in the human brain.
Related JoVE Video
Cerebral microbleeds: burden assessment by using quantitative susceptibility mapping.
Radiology
PUBLISHED: 11-04-2011
Show Abstract
Hide Abstract
To assess quantitative susceptibility mapping (QSM) for reducing the inconsistency of standard magnetic resonance (MR) imaging sequences in measurements of cerebral microbleed burden.
Related JoVE Video
Morphology enabled dipole inversion for quantitative susceptibility mapping using structural consistency between the magnitude image and the susceptibility map.
Neuroimage
PUBLISHED: 05-06-2011
Show Abstract
Hide Abstract
The magnetic susceptibility of tissue can be determined in gradient echo MRI by deconvolving the local magnetic field with the magnetic field generated by a unit dipole. This Quantitative Susceptibility Mapping (QSM) problem is unfortunately ill-posed. By transforming the problem to the Fourier domain, the susceptibility appears to be undersampled only at points where the dipole kernel is zero, suggesting that a modest amount of additional information may be sufficient for uniquely resolving susceptibility. A Morphology Enabled Dipole Inversion (MEDI) approach is developed that exploits the structural consistency between the susceptibility map and the magnitude image reconstructed from the same gradient echo MRI. Specifically, voxels that are part of edges in the susceptibility map but not in the edges of the magnitude image are considered to be sparse. In this approach an L1 norm minimization is used to express this sparsity property. Numerical simulations and phantom experiments are performed to demonstrate the superiority of this L1 minimization approach over the previous L2 minimization method. Preliminary brain imaging results in healthy subjects and in patients with intracerebral hemorrhages illustrate that QSM is feasible in practice.
Related JoVE Video
Three-dimensional flow-independent balanced steady-state free precession vessel wall MRI of the popliteal artery: preliminary experience and comparison with flow-dependent black-blood techniques.
J Magn Reson Imaging
PUBLISHED: 05-02-2011
Show Abstract
Hide Abstract
To examine the feasibility of flow-independent T2-prepared inversion recovery (T2IR) black-blood (BB) magnetization preparation for three-dimensional (3D) balanced steady-state free precession (SSFP) vessel wall MRI of the popliteal artery, and to evaluate its performance relative to flow-dependent double inversion recovery (DIR), spatial presaturation (SPSAT), and motion-sensitizing magnetization preparation (MSPREP) BB techniques in healthy volunteers.
Related JoVE Video
A fast Edge-preserving Bayesian reconstruction method for Parallel Imaging applications in cardiac MRI.
Magn Reson Med
PUBLISHED: 04-16-2011
Show Abstract
Hide Abstract
Among recent parallel MR imaging reconstruction advances, a Bayesian method called Edge-preserving Parallel Imaging reconstructions with GRAph cuts Minimization (EPIGRAM) has been demonstrated to significantly improve signal-to-noise ratio when compared with conventional regularized sensitivity encoding method. However, EPIGRAM requires a large number of iterations in proportion to the number of intensity labels in the image, making it computationally expensive for high dynamic range images. The objective of this study is to develop a Fast EPIGRAM reconstruction based on the efficient binary jump move algorithm that provides a logarithmic reduction in reconstruction time while maintaining image quality. Preliminary in vivo validation of the proposed algorithm is presented for two-dimensional cardiac cine MR imaging and three-dimensional coronary MR angiography at acceleration factors of 2-4. Fast EPIGRAM was found to provide similar image quality to EPIGRAM and maintain the previously reported signal-to-noise ratio improvement over regularized sensitivity encoding method, while reducing EPIGRAM reconstruction time by 25-50 times.
Related JoVE Video
Morphology enabled dipole inversion (MEDI) from a single-angle acquisition: comparison with COSMOS in human brain imaging.
Magn Reson Med
PUBLISHED: 04-04-2011
Show Abstract
Hide Abstract
Magnetic susceptibility varies among brain structures and provides insights into the chemical and molecular composition of brain tissues. However, the determination of an arbitrary susceptibility distribution from the measured MR signal phase is a challenging, ill-conditioned inverse problem. Although a previous method named calculation of susceptibility through multiple orientation sampling (COSMOS) has solved this inverse problem both theoretically and experimentally using multiple angle acquisitions, it is often impractical to carry out on human subjects. Recently, the feasibility of calculating the brain susceptibility distribution from a single-angle acquisition was demonstrated using morphology enabled dipole inversion (MEDI). In this study, we further improved the original MEDI method by sparsifying the edges in the quantitative susceptibility map that do not have a corresponding edge in the magnitude image. Quantitative susceptibility maps generated by the improved MEDI were compared qualitatively and quantitatively with those generated by calculation of susceptibility through multiple orientation sampling. The results show a high degree of agreement between MEDI and calculation of susceptibility through multiple orientation sampling, and the practicality of MEDI allows many potential clinical applications.
Related JoVE Video
A novel background field removal method for MRI using projection onto dipole fields (PDF).
NMR Biomed
PUBLISHED: 03-08-2011
Show Abstract
Hide Abstract
For optimal image quality in susceptibility-weighted imaging and accurate quantification of susceptibility, it is necessary to isolate the local field generated by local magnetic sources (such as iron) from the background field that arises from imperfect shimming and variations in magnetic susceptibility of surrounding tissues (including air). Previous background removal techniques have limited effectiveness depending on the accuracy of model assumptions or information input. In this article, we report an observation that the magnetic field for a dipole outside a given region of interest (ROI) is approximately orthogonal to the magnetic field of a dipole inside the ROI. Accordingly, we propose a nonparametric background field removal technique based on projection onto dipole fields (PDF). In this PDF technique, the background field inside an ROI is decomposed into a field originating from dipoles outside the ROI using the projection theorem in Hilbert space. This novel PDF background removal technique was validated on a numerical simulation and a phantom experiment and was applied in human brain imaging, demonstrating substantial improvement in background field removal compared with the commonly used high-pass filtering method.
Related JoVE Video
Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging.
Magn Reson Imaging
PUBLISHED: 02-24-2011
Show Abstract
Hide Abstract
A free-breathing 3D cine steady-state free precession (SSFP) technique was developed using the z intensity-weighted position (ZIP) which is the center of mass of a projection along the slice direction as a respiratory gating signal. The ZIP signal was continuously acquired using a slice encoded k-space center sampling in every TR. The performance of this gating method was compared with a method using the k-space center signal (KC) and with conventional 2D breath-hold cine SSFP in healthy subjects by measuring image quality and left ventricular function. The preliminary data obtained here demonstrated that the ZIP gating method provided superior respiratory motion artifact suppression when compared to the KC gating and provided left ventricular ejection fractions, and end-diastolic and end-systolic volumes similar to those obtained with the breath-hold 2D cine SSFP acquisition.
Related JoVE Video
A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.
NMR Biomed
PUBLISHED: 06-18-2010
Show Abstract
Hide Abstract
A generalized autocalibrating partially parallel acquisition (GRAPPA) method for radial k-space sampling is presented that calculates GRAPPA weights without synthesized or acquired calibration data. Instead, GRAPPA weights are fitted to the undersampled data as if they were the calibration data. Because the relative k-space shifts associated with these GRAPPA weights vary for a radial trajectory, new GRAPPA weights can be resampled for arbitrary shifts through interpolation, which are then used to generate missing projections between the acquired projections. The method is demonstrated in phantoms and in abdominal and brain imaging. Image quality is similar to radial GRAPPA using fully sampled calibration data, and improved relative to a previously described self-calibrated radial GRAPPA technique.
Related JoVE Video
Unambiguous identification of superparamagnetic iron oxide particles through quantitative susceptibility mapping of the nonlinear response to magnetic fields.
Magn Reson Imaging
PUBLISHED: 05-19-2010
Show Abstract
Hide Abstract
Superparamagnetic iron oxide (SPIO) particles generate signal void regions on gradient echo images due to their strong magnetization. In practice, the signal void region might be indistinguishable from that generated by air. However, the response of SPIO to an externally applied magnetic field is nonlinear. Magnetization of SPIO saturates at around 1 T while magnetization of water and air increase linearly with field strength. Phantom experiment and mice experiments demonstrated the feasibility of a nonambiguous identification of superparamagnetic contrast agents.
Related JoVE Video
Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.
Magn Reson Med
PUBLISHED: 05-01-2010
Show Abstract
Hide Abstract
A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired at every pulse repetition time, no extra scan time is required for sampling the k-space center. Temporal filtering based on density compensation is used for radial reconstruction to achieve high signal-to-noise ratio and contrast-to-noise ratio. High correlation between the self-gating signals and external gating signals is demonstrated. This respiratory and cardiac self-gated, free-breathing, three-dimensional, radial cardiac cine imaging technique provides image quality comparable to that acquired with the multiple breath-hold two-dimensional Cartesian steady-state free precession technique in short-axis, four-chamber, and two-chamber orientations. Functional measurements from the three-dimensional cardiac short axis cine images are found to be comparable to those obtained using the standard two-dimensional technique.
Related JoVE Video
Effect of blood flow on double inversion recovery vessel wall MRI of the peripheral arteries: quantitation with T2 mapping and comparison with flow-insensitive T2-prepared inversion recovery imaging.
Magn Reson Med
PUBLISHED: 02-27-2010
Show Abstract
Hide Abstract
Blood suppression in the lower extremities using flow-reliant methods such as double inversion recovery may be problematic due to slow blood flow. T(2) mapping using fast spin echo (FSE) acquisition was utilized to quantitate the effectiveness of double inversion recovery blood suppression in 13 subjects and showed that 25 +/- 12% of perceived vessel wall pixels in the popliteal arteries contained artifactual blood signal. To overcome this problem, a flow-insensitive T(2)-prepared inversion recovery sequence was implemented and optimal timing parameters were calculated for FSE acquisition. Black blood vessel wall imaging of the popliteal and femoral arteries was performed using two-dimensional T(2)-prepared inversion recovery-FSE in the same 13 subjects. Comparison with two-dimensional double inversion recovery-FSE showed that T(2)-prepared inversion recovery-FSE reduced wall-mimicking blood artifacts that inflated double inversion recovery-FSE vessel wall area measurements in the popliteal artery.
Related JoVE Video
Nonlinear regularization for per voxel estimation of magnetic susceptibility distributions from MRI field maps.
IEEE Trans Med Imaging
PUBLISHED: 06-05-2009
Show Abstract
Hide Abstract
Magnetic susceptibility is an important physical property of tissues, and can be used as a contrast mechanism in magnetic resonance imaging (MRI). Recently, targeting contrast agents by conjugation with signaling molecules and labeling stem cells with contrast agents have become feasible. These contrast agents are strongly paramagnetic, and the ability to quantify magnetic susceptibility could allow accurate measurement of signaling and cell localization. Presented here is a technique to estimate arbitrary magnetic susceptibility distributions by solving an ill-posed inversion problem from field maps obtained in an MRI scanner. Two regularization strategies are considered: conventional Tikhonov regularization and a sparsity promoting nonlinear regularization using the l(1) norm. Proof of concept is demonstrated using numerical simulations, phantoms, and in a stroke model in a rat. Initial experience indicates that the nonlinear regularization better suppresses noise and streaking artifacts common in susceptibility estimation.
Related JoVE Video
In vivo quantification of femoral-popliteal compression during isometric thigh contraction: Assessment using MR angiography.
J Magn Reson Imaging
PUBLISHED: 04-24-2009
Show Abstract
Hide Abstract
To quantify femoral-popliteal vessel deformation during thigh contraction.
Related JoVE Video
Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI.
Magn Reson Med
PUBLISHED: 02-28-2009
Show Abstract
Hide Abstract
Magnetic susceptibility differs among tissues based on their contents of iron, calcium, contrast agent, and other molecular compositions. Susceptibility modifies the magnetic field detected in the MR signal phase. The determination of an arbitrary susceptibility distribution from the induced field shifts is a challenging, ill-posed inverse problem. A method called "calculation of susceptibility through multiple orientation sampling" (COSMOS) is proposed to stabilize this inverse problem. The field created by the susceptibility distribution is sampled at multiple orientations with respect to the polarization field, B(0), and the susceptibility map is reconstructed by weighted linear least squares to account for field noise and the signal void region. Numerical simulations and phantom and in vitro imaging validations demonstrated that COSMOS is a stable and precise approach to quantify a susceptibility distribution using MRI.
Related JoVE Video
Free-breathing 3-dimensional steady-state free precession coronary magnetic resonance angiography: comparison of four navigator gating techniques.
Magn Reson Imaging
PUBLISHED: 01-17-2009
Show Abstract
Hide Abstract
This work compared the performance of four navigator gating algorithms [accept/reject (A/R), diminishing variance algorithm (DVA), phase ordering with automatic window selection (PAWS) and retrospective gating (RETRO)] in suppressing respiratory motion artifacts in free-breathing 3D balanced steady-state free precession coronary MRA. In 10 volunteers, the right coronary artery (RCA) or the left anterior descending artery (LAD) was imaged (both if time permitted) at 1.5 T with the four gating techniques in random order. Vessel signal, vessel contrast and motion suppression were scored by the consensus of two blinded readers. In 15 imaged vessels (nine RCA and six LAD), PAWS provided significantly better image quality than A/R (P<.05), DVA (P=.02) and RETRO (P=.002). While the quality difference between A/R and DVA was not statistically significant, both algorithms yielded significantly better image quality than RETRO. PAWS and DVA were the most efficient algorithms, providing an approximately 20% and 40% relative increase in average navigator efficiency compared to A/R and RETRO, respectively.
Related JoVE Video
Improved hepatic arterial phase MRI with 3-second temporal resolution.
J Magn Reson Imaging
Show Abstract
Hide Abstract
To assess 3-s temporal resolution for arterial phase bolus timing on dynamic liver MRI.
Related JoVE Video
Reducing the object orientation dependence of susceptibility effects in gradient echo MRI through quantitative susceptibility mapping.
Magn Reson Med
Show Abstract
Hide Abstract
This study demonstrates the dependence of non-local susceptibility effects on object orientation in gradient echo MRI and the reduction of non-local effects by deconvolution using quantitative susceptibility mapping. Imaging experiments were performed on a 3T MRI system using a spoiled 3D multi-echo GRE sequence on phantoms of known susceptibilities, and on human brains of healthy subjects and patients with intracerebral hemorrhages. Magnetic field measurements were determined from multiple echo phase data. To determine the quantitative susceptibility mapping, these field measurements were deconvolved through a dipole inversion kernel under a constraint of consistency with the magnitude images. Phantom and human data demonstrated that the hypointense region in GRE magnitude image corresponding to a susceptibility source increased in volume with TE and varied with the source orientation. The induced magnetic field extended beyond the susceptibility source and varied with its orientation. In quantitative susceptibility mapping, these blooming artifacts, including their dependence on object orientation, were reduced, and the material susceptibilities were quantified.
Related JoVE Video
Nonlinear formulation of the magnetic field to source relationship for robust quantitative susceptibility mapping.
Magn Reson Med
Show Abstract
Hide Abstract
Quantitative susceptibility mapping (QSM) opens the door for measuring tissue magnetic susceptibility properties that may be important biomarkers, and QSM is becoming an increasingly active area of scientific and clinical investigations. In practical applications, there are sources of errors for QSM including noise, phase unwrapping failures, and signal model inaccuracy. To improve the robustness of QSM quality, we propose a nonlinear data fidelity term for frequency map estimation and dipole inversion to reduce noise and effects of phase unwrapping failures, and a method for model error reduction through iterative tuning. Compared with the previous phase based linear QSM method, this nonlinear QSM method reduced salt and pepper noise or checkerboard pattern in high susceptibility regions in healthy subjects and markedly reduced artifacts in patients with intracerebral hemorrhages.
Related JoVE Video
Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction.
Magn Reson Med
Show Abstract
Hide Abstract
Time-resolved imaging is crucial for the accurate diagnosis of liver lesions. Current contrast enhanced liver magnetic resonance imaging acquires a few phases in sequential breath-holds. The image quality is susceptible to bolus timing errors, which could result in missing the critical arterial phase. This impairs the detection of malignant tumors that are supplied primarily by the hepatic artery. In addition, the temporal resolution may be too low to reliably separate the arterial phase from the portal venous phase. In this study, a method called temporal resolution acceleration with constrained evolution reconstruction was developed with three-dimensional volume coverage and high-temporal frame rate. Data is acquired using a stack of spirals sampling trajectory combined with a golden ratio view order using an eight-channel coil array. Temporal frames are reconstructed from vastly undersampled data sets using a nonlinear inverse algorithm assuming that the temporal changes are small at short time intervals. Numerical and phantom experimental validation is presented. Preliminary in vivo results demonstrated high spatial resolution dynamic three-dimensional images of the whole liver with high frame rates, from which numerous subarterial phases could be easily identified retrospectively.
Related JoVE Video
T2 prep three-dimensional spiral imaging with efficient whole brain coverage for myelin water quantification at 1.5 tesla.
Magn Reson Med
Show Abstract
Hide Abstract
Quantitative assessment of myelination is important for characterizing tissue damage and evaluating response to therapy in white matter diseases such as multiple sclerosis. Conventional multicomponent T(2) relaxometry based on the two-dimensional (2D) multiecho spin echo sequence is a promising method to measure myelin water fraction, but its clinical utility is impeded by the prohibitively long data acquisition and limited brain coverage. The objective of this study was to develop a signal-to-noise ratio efficient 3D T(2) prep spiral gradient echo (3D SPIRAL) sequence for full brain T(2) relaxometry and to validate this sequence using 3D multiecho spin echo as reference standard in healthy brains at 1.5 T. 3D SPIRAL was found to provide similar myelin water fraction in six selected white and gray matter areas using region-of-interest signal averaging analysis (N = 7, P > 0.05). While 3D multiecho spin echo only provided partial brain coverage, 3D SPIRAL enabled whole brain coverage with a fivefold higher acquisition speed per imaging slice and similar signal-to-noise ratio efficiency. Both 3D sequences provided superior signal-to-noise ratio efficiency when compared to the conventional 2D multiecho spin echo approach.
Related JoVE Video
Flip angle profile correction for T? and T? quantification with look-locker inversion recovery 2D steady-state free precession imaging.
Magn Reson Med
Show Abstract
Hide Abstract
Fast methods using balanced steady-state free precession have been developed to reduce the scan time of T? and T? mapping. However, flip angle (FA) profiles created by the short radiofrequency pulses used in steady-state free precession deviate substantially from the ideal rectangular profile, causing T? and T? mapping errors. The purpose of this study was to develop a FA profile correction for T? and T? mapping with Look-Locker 2D inversion recovery steady-state free precession and to validate this method using 2D spin echo as a reference standard. Phantom studies showed consistent improvement in T? and T? accuracy using profile correction at multiple FAs. Over six human calves, profile correction provided muscle T? estimates with mean error ranging from excellent (-0.6%) at repetition time/FA = 18 ms/60° to acceptable (6.8%) at repetition time/FA = 4.9 ms/30°, while muscle T? estimates were less accurate with mean errors of 31.2% and 47.9%, respectively.
Related JoVE Video
Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.
IEEE Trans Med Imaging
Show Abstract
Hide Abstract
Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spatial prior information, has been proposed to generate a quantitative susceptibility map (QSM). The accuracy of QSM can be validated experimentally. However, there is not yet a rigorous mathematical demonstration of accuracy for a general regularized approach or for MEDI specifically. The error in the susceptibility map reconstructed by MEDI is expressed in terms of the acquisition noise and the error in the spatial prior information. A detailed analysis demonstrates that the error in the susceptibility map reconstructed by MEDI is bounded by a linear function of these two error sources. Numerical analysis confirms that the error of the susceptibility map reconstructed by MEDI is on the same order of the noise in the original MRI data, and comprehensive edge detection will lead to reduced model error in MEDI. Additional phantom validation and human brain imaging demonstrated the practicality of the MEDI method.
Related JoVE Video

What is Visualize?

JoVE Visualize is a tool created to match the last 5 years of PubMed publications to methods in JoVE's video library.

How does it work?

We use abstracts found on PubMed and match them to JoVE videos to create a list of 10 to 30 related methods videos.

Video X seems to be unrelated to Abstract Y...

In developing our video relationships, we compare around 5 million PubMed articles to our library of over 4,500 methods videos. In some cases the language used in the PubMed abstracts makes matching that content to a JoVE video difficult. In other cases, there happens not to be any content in our video library that is relevant to the topic of a given abstract. In these cases, our algorithms are trying their best to display videos with relevant content, which can sometimes result in matched videos with only a slight relation.