A Microfluidic Device with Groove Patterns for Studying Cellular Behavior
Bong Geun Chung, Amir Manbachi, Ali Khademhosseini
Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology; Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital

Sorry for the inconvenience.
This content requires the Adobe Flash Player 9 or higher.
Click Here to Get Flash

0:00 Creating channel inlet and outlet0

0:06 Introduction6

0:21 Subscription Lock21

1:27 Microfabrication of microfluidic device87

1:45 Preparation of PDMS mixture105

2:42 Patterning PDMS molds162

3:36 Removing bubbles by vacuum216

4:21 Assembly of microfluidic device261

4:55 Cutting layers of microfluidic device295

6:10 Bonding the microfluidic device layers370

8:19 Coating channels with fibronectin499

9:08 Experiment: monitoring apoptosis548

9:09 Cell seeding549

11:31 Application of reagents691

13:32 Time lapse of apoptosis812

We describe a microfluidic device with microgrooved patterns for studying cellular behavior. This microfluidic platform consists of a top fluidic channel and a bottom microgrooved substrate. To fabricate the microgrooved channels, a top poly(dimethylsiloxane) (PDMS) mold containing the impression of the microfluidic channels was aligned and bonded to a microgrooved substrate. Using this device, mouse fibroblast cells were immobilized and patterned within microgrooved substrates (25, 50, 75, and 100 μm wide). To study apoptosis in a microfluidic device, media containing hydrogen peroxide, Annexin V, and propidium iodide was perfused into the fluidic channel for 2 hours. We found that cells exposed to the oxidative stress became apoptotic. These apoptotic cells were confirmed by Annexin V that bound to phosphatidylserine at the outer leaflet of the plasma membrane during the apoptosis process. Using this microfluidic device with microgrooved patterns, the apoptosis process was observed in real-time and analyzed by using an inverted microscope containing an incubation chamber (37°C, 5% CO2). Therefore, this microfluidic device incorporated with microgrooved substrates could be useful for studying the cellular behavior and performing high-throughput drug screening.

 

You need a subscription to be able to access files

 

You must be subscribed to access this content.
Please click here to subscribe or get a FREE trial.

A. Microfabrication of the microfluidic device

  1. 4-inch Si wafer is treated with reactive oxygen plasma (5 min at 30W, Harrick Scientific, NY).
  2. Negative photoresist (SU-8 2015, Microchem, MA) is spin-coated at 900 rpm for 1 min on a Si wafer.
  3. The wafer is soft baked at 95°C for 6 min on a hotplate and is exposed to UV light (200W) for 4 min through a mask film containing microchannels.
  4. The wafer is post baked at 95°C for 6 min and is developed using SU-8 photoresist developer.
  5. The photoresist patterned wafer containing microchannels is placed in a Petri-dish.
  6. Poly(dimethylsiloxane) (PDMS) (Sylgard 184) molds are fabricated by mixing silicone elastomer and curing agent (10:1 ratio).
  7. The PDMS mixture is poured onto the Si master mold and is placed on a vacuum desiccator to remove bubbles.
  8. PDMS is cured at 70°C for 1~2 hours.
  9. PDMS molds are then peeled off from the Si master mold.

B. Assembling the device

  1. 40 µm thick top fluidic channels and 40 µm thick bottom microgrooved channels (25, 50, 75, and 100 μm wide) are obtained from two different Si master molds.
  2. Channel inlet and outlet of the fluidic device are punched.
  3. Fluidic channels and microgroove channels are irreversibly bonded by the reactive oxygen plasma (5 min at 30W, Harrick Scientific, NY).
  4. Extracellular matrix (ECM) (i.e. fibronectin) is coated inside microfluidic device for 1 hour in incubator (37°C).

C. Cell seeding and experimental setup

  1. NIH-3T3 mouse fibroblasts are cultured in a tissue culture flask using Dulbecco's Modified Eagle's Media (DMEM) containing 10% Fetal Bovine Serum (FBS).
  2. Cells are trypsinized and dissociated.
  3. Dissociated cells are loaded into the microgroove channels at the cell density of 3×106 cells/ml (Figure 1).

    Figure 1 
       Figure 1

  4. 2 mL media, 100 mM H2O2, and apoptosis assay (20 µL Annexin V and 40 µL propidium iodide, Invitrogen, CA) are infused into a channel using a syringe pump (1 µl/min).
  5. Cells are real-time monitored by using an inverted microscope (Nikon TE 2000).

Cells were immobilized and patterned within microgrooved substrates in a microfluidic device. The apoptosis process of cells exposed to hydrogen peroxide was observed in real-time and analyzed by using Annexin V and propidium iodide. Thus, this microfluidic device containing microgroove channels could be useful for high-throughput drug screening.

Name  Type  Company  Catalog Number  Comments
PDMS Reagent K.R. Anderson Co. Inc. 2065622 Poly(dimethylsiloxane), Dow Corning Sylgard 184 (8.6 lb)
DMEM medium Invitrogen 11965 Dulbecco’s Modified Eagle’s Media
FBS serum Invitrogen 10082-147 Fetal Bovine Serum
Hydrogen peroxide Reagent Sigma Aldrich H1009
Apoptosis assay Invitrogen V13242 Annexin A, propidium iodide
Negative photoresist Microchem SU-8 2015
Si wafer Tool 4 inch silicone wafer
Reactive oxygen plasma Reagent Harrick Scientific treat wafer 5 min at 30W
inverted microscope Tool Nikon TE 2000

1. Chung B.G., Park J.W., Hu J.S., Huang C., Monuki E.S., Jeon N.L. A hybrid microfluidic-vacuum device for interfacing with conventional cell culture platform. BMC Biotechnol., 7(1), 60 (2007)

2. Khademhosseini A., Yeh J., Eng G., Karp J., Kaji H., Borenstein J., Farokhzad O.C., Langer R. Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays. Lab Chip 5(12), 1380-1386 (2005)

3. Whittemore E.R., Loo D.T., Watt J.A., Cotman C.W. A detailed analysis of hydrogen peroxide-induced cell death in primary neuronal culture. Neuroscience 67, 921-932 (1995)

Chung BG, Manbachi A, Khademhosseini A (2007). A Microfluidic Device with Groove Patterns for Studying Cellular Behavior. JoVE. 7. http://www.jove.com/index/details.stp?id=270, doi: 10.3791/270
Post a Question / Comment / Request

Allowed tags: i, b, u, sup, sub

Please log into your account at the top of this page or

Create a New Account.

Sign your name and post:

Email:

Post Comment

Name:

OR

Mailer.URL:

http://www.jove.com/index/details.stp?id=270

 

Subscription Required

to view this article in its entirety

Free Trial
Subscribe
Recommend to Librarian

Info

08/30/2007

Publish Date

11944 

Views

 0 

Comments

doi: 10.3791/270 

Tracking

You must be logged in to track comments.

Share this article:

 Email this Article

My Stuff (Please log in to use)

Store a note

Make a Suggestion

Is there a technique you would like to see published?  Click the button above to make a suggestion.

 

 

About Jove

 

Journal of Visualized Experiments (JoVE) is an online research journal employing visualization to increase reproducibility and transparency in biological sciences.

 

ISSN 1940-087X

 

 

Quick links

 

* Welcome  

* Browse  

* Submit  

* About  

* Editorial Board  

* Press  

* Advertising

* Contact  

* Policies

* Article Index

* Sponsors

* Press Access

* Troubleshooting

* Minerva

 

 

* Twitter.com/JoveJournal

* FaceBook

Subscribe

You don't have to create an account to receive email notifications. 

Please enter your email:

Submit

Copyright (C) JoVE 2006-2008 All Rights Reserved.  Powered by TARGET.  JoVE Site Version 1.893