Journal of Visualized Experiments

Sign In
New Account Forgot Password
Search
Home Browse For Authors Subscribe
< Previous Article
Next Article >
In Vivo 2-Photon Calcium Imaging in Layer 2/3 of Mice
Peyman Golshani, Carlos Portera-Cailliau
Department of Neurology, University of California, Los Angeles

Sorry for the inconvenience.
This content requires the Adobe Flash Player 9 or higher.
Click Here to Get Flash

0:00 Title0

0:21 Subscription Lock21

0:46 Introduction46

1:15 Injecting the Fluorescent Calcium Indicator Dye into the Cortex75

5:36 Imaging Cortical Calcium Dynamics in vivo336

6:57 Typical Example of In Vivo Calcium Imaging417

7:23 Conclusion443

To understand network dynamics of microcircuits in the neocortex, it is essential to simultaneously record the activity of a large number of neurons . In-vivo two-photon calcium imaging is the only method that allows one to record the activity of a dense neuronal population with single-cell resolution . The method consists in implanting a cranial imaging window, injecting a fluorescent calcium indicator dye that can be taken up by large numbers of neurons and finally recording the activity of neurons with time lapse calcium imaging using an in-vivo two photon microscope. Co-injection of astrocyte-specific dyes allows one to differentiate neurons from astrocytes. The technique can be performed in mice expressing fluorescent molecules in specific subpopulations of neurons to better understand the network interactions of different groups of cells.

 

You need a subscription to be able to access files

 

You must be subscribed to access this content.
Please click here to subscribe or get a FREE trial.
  1. Prepare the fluorescent calcium indicator solution. We use acetoxymethyl ester dyes, or AM dyes for short. These are dyes that can be taken up by cells when injected extracellularly. We typically use Oregon-Green BAPTA-1 AM or Fluo-4 AM at a concentration of 1 mM. AM dyes can be obtained from Invitrogen in 50 microgram vials. We first prepare a 20% solution of Pluronic F-127 in DMSO. We warm the solution prior to use every day until its clear. We dissolve the calcium indicator the 20% Pluronic F-127/DMSO for 15-20 minutes to a concentration of 10 mM. We then dilute the solution to 1mM in a solution containing, in mM: 150 NaCl, 2.5 KCl, 10 Hepes, pH 7.4. In addition, 100 µM Sulforhodamine 101 is usually included to label astrocytes and visualize the pipette during the injection. We filter the solution prior to injection with a 0.49 micron centrifugal filter (Stosiek et al., 2003; Garaschuk et al., 2006).

  2. Implant a cranial window over the area to be imaged. We have described the general approach in JoVE, but the following modifications are important for calcium dye injection:

    Make a smaller craniotomy of 2 mm in diameter over the cortical area of interest, taking extreme care not to damage the underlying dura. Secure a coverslip in place over the craniotomy, but only partially cover the craniotomy, leaving a small gap between the edge of the craniotomy and the glass coverslip to allow room for a pipette to enter the cortex obliquely. Prior to injection, make a shallow well with dental cement around the craniotomy. The well should extend as rostral in direction and be shallow enough to allow insertion of the micropipette for injection.

  3. Transfer the mouse transferred to the stage of the microscope and immobilize the head, as shown in our video on blood flow imaging.

  4. Pull glass microelectrode pipettes to a tip diameter yielding 2-4 Mega Ohms in resistance, using a pipette puller. Load the calcium indicator dye mix onto the glass pipette using a microsyringe. Using a micromanipulator, gently lower the micropipette onto the surface of the brain using a 4X objective, which is then finely positioned under a 40X objective. Choose a suitable location for injection, such that there are few or no overlying blood vessels to obscure the imaging. Using two-photon microscopy, the tip of the pipette is visualized and advanced slowly into the cortex, to a depth of 200 micrometers below the dura. Then, pressure inject the dye mixture at 10 PSI for 1 minute using a Picospritzer. We usually deliver two to four injections of the AM calcium dye mix, separated in space by approximately 200-300 microns. This bulk loading approach of slightly overlapping injections ensures that an area as large as 600 x 600 microns is adequately stained for calcium imaging. Begin imaging 1 hour after the injection of the AM dye mixture, to allow for the dye to diffuse and be taken up by neurons.

  5. Perform in-vivo two-photon imaging with a custom made two-photon microscope using a Chameleon Ti-Sapphire Laser (tuned to 800-880 nm) and Cambridge Technology galvanometer mirrors. We aquire images using ScanImage Software developed in Karel Svoboda's laboratory (Pologruto et al., 2003). Laser Power is typically well below 70 mW at the sample. Whole field images are acquired either using a 20X (0.95 NA) or 40X (0.8 NA) Olympus objectives, at 1.95-15.63 frames per second (512 x 256 pixels to 256 x 64 pixels). Line scans are acquired at 500 Hz. During imaging, animals are kept under light isoflurane anesthesia (0.6-0.9%), and are also kept at 37°C using a Harvard Apparatus Temperature Control Device. Care is taken to keep the respiratory rate of animals as close to 100 breaths/minute as possible. This level of anesthesia use is the lowest level that immobilizes the animal, but still permits spontaneous activity to be recorded.

The advantage of this method over electrophysiological recordings is that it is less invasive and allows the recordings of activity in dense neuronal neuronal networks. When doing this procedure it s important to remember to take extreme care when performing the craniotomy not to damage the dura. Even a small amount of subdural bleeding with greatly obscure the imaging.

We would like to acknowledge Olga Garaschuk for helpful discussions on optimizing the bulk loading of calcium indicators.

Name  Type  Company  Catalog Number  Comments
Oregon Green BAPTA1-AM Reagent Invitrogen O-6807
Fluo 4- AM Reagent Invitrogen F-14201
Sulforhodamine 101 Reagent Invitrogen S-359
Pluronic F-127 in DMSO Reagent Invitrogen P-3000MP
Centrifugal Filter (0.45 micron) Reagent Millipore UFC3 0HV 0S

1. Garaschuk O., Milos R.I.  & Konnerth A.  Targeted bulk-loading of fluorescent indicators for two-photon brain imaging in vivo.;1(1): 380-6.Nat Protoc. (2006)

2. Stosiek, C., Garaschuk, O., Holthoff, K.,& Konnerth,A. In-vivo two-photon calcium imaging of neuronal networks. Proc Natl Acad Sci USA 100(12), 7319-24 (2003)

3. Pologruto, T.A., Sabatini, B.L., Svoboda, K.. ScanImage: flexible software for operating laser scanning microscopes.   Biomed Eng Online 2:13 (2003).

Golshani P, Portera-Cailliau C (2008). In Vivo 2-Photon Calcium Imaging in Layer 2/3 of Mice. JoVE. 13. http://www.jove.com/index/details.stp?id=681, doi: 10.3791/681
Post a Question / Comment / Request

Allowed tags: i, b, u, sup, sub

Please log into your account at the top of this page or

Create a New Account.

Sign your name and post:

Email:

Post Comment

Name:

OR

07/09/2008 3:59:50 PM
nikitab responded with a statement of type: Neutral

test

Reply to This
0
0
07/15/2008 11:27:44 AM
James T. Russell responded with a statement of type: Question

Dear Dr. Golshani,

    Do you close the craniotomy site completely with the coverslip and secure it after the injection fo the indicator?  Or do you image with the half open craniotomy hole?  Also during craniotomy, do you keep the animal under deeper anesthesia unlike during imaging?

Thanks

James T. Russell

Reply to This
0
0
            
08/02/2008 8:30:54 PM
Peyman Golshani responded with a statement of type: Neutral

Hi James,

 

I image with a 2/3 closed craniotomy.  The craniotomy is performed under isoflurane anesthesia (breath-rate around 60-80) with all withdrawl reflexes completely suppressed.  We image animals under light isoflurane anesthesia (with the breath-rate close to 100 bpm).

Reply to This
0
0
07/17/2008 11:56:06 AM
Romain Franconville responded with a statement of type: Question

Any trick to go trough the dura with the pipette ? (as opposed to just push the dura with the pipette)

Thanks

Reply to This
0
0
            
08/02/2008 8:32:47 PM
Peyman Golshani responded with a statement of type: Neutral

We position the pipette at 30 degrees to the dura, and then slowly advance it into the brain.  We have had no problems with the pipette breaking or with penetration of the dura.  We are imaging mice.  The situation may be different with rats or other animals.

 

Peyman

Reply to This
0
0
11/04/2009 7:44:26 AM
li fei responded with a statement of type: Neutral
Dear Dr. Golshani,
Thanks for your share.In my lab,we use P-97 Micropipette Puller.Could you tell me the Parameters for pulling the Micropipette in your experiment?
Thanks.
feili
Reply to This
0
0

Mailer.URL:

http://www.jove.com/index/details.stp?id=681

 

Subscription Required

to view this article in its entirety

Free Trial
Subscribe
Recommend to Librarian

Info

03/13/2008

Publish Date

13050 

Views

 5 

Comments

doi: 10.3791/681 

Traffic Stats

Tracking

You must be logged in to track comments.

Share this article:

 Email this Article

My Stuff (Please log in to use)

Store a note

Make a Suggestion

Is there a technique you would like to see published?  Click the button above to make a suggestion.

 

 

About Jove

 

Journal of Visualized Experiments (JoVE) is an online research journal employing visualization to increase reproducibility and transparency in biological sciences.

 

ISSN 1940-087X

 

 

Quick links

 

* Welcome  

* Browse  

* Submit  

* About  

* Editorial Board  

* Press  

* Advertising

* Contact  

* Policies

* Article Index

* Sponsors

* Press Access

* Troubleshooting

 

 

* Twitter.com/JoveJournal

* FaceBook

Subscribe

You don't have to create an account to receive email notifications. 

Please enter your email:

Submit

Copyright (C) JoVE 2006-2008 All Rights Reserved.  Powered by TARGET.  JoVE Site Version 1.893

 

 

Feedback Form