The Journal of Visualized Experiments (JoVE) is a peer reviewed, PubMed-indexed video journal. Our mission is to increase the productivity of scientific research.

Recommend to Librarian

Refine your search:

Containing Text
Filter by author or institution
GO
Filter by publication date
From:
October, 2006
Until:
Today
Filter by section
General
Neuroscience
Immunology and Infection
Clinical and Translational Medicine
Bioengineering
Applied Physics
Chemistry
 
 
 JoVE Immunology and Infection

Generation of Multivirus-specific T Cells to Prevent/treat Viral Infections after Allogeneic Hematopoietic Stem Cell Transplant


JoVE 2736 5/27/2011

Center for Cell and Gene Therapy, Baylor College of Medicine

A rapid, simple and cost-effective protocol for the generation of donor-derived multivirus-specific CTLs (rCTL) for infusion to allogeneic hematopoietic stem cell transplant (HSCT) recipients at risk of developing CMV, Adv or EBV infections. This manufacturing process is GMP-compliant and should ensure the broader implementation of T-cell immunotherapy beyond specialized centers.

Results below contain some, but not all of your search terms.
 JoVE General

Generation of Stable Human Cell Lines with Tetracycline-inducible (Tet-on) shRNA or cDNA Expression


JoVE 50171 3/05/2013

1UCL Cancer Institute, 2Friedrich Miescher Institute for Biomedical Research

A rapid and simple way to generate human cell lines with inducible and reversible cDNA overexpression or shRNA-mediated knock-down of the gene of interest. This method enables researchers to reliably and highly reproducibly manipulate cell lines that are difficult to alter by transient transfection methods or conventional knockdown/knockout strategies.

Results below contain some, but not all of your search terms.
 JoVE General

Design and Use of Multiplexed Chemostat Arrays


JoVE 50262 2/23/2013

Department of Genome Sciences, University of Washington

We developed and validated a small-footprint array of miniature chemostats built from readily available parts for low cost. Physiological and experimental evolution results were similar to larger volume chemostats. The ministat array provides a compact, inexpensive, and accessible platform for traditional chemostat experiments, functional genomics, and chemical screening applications.

Results below contain some, but not all of your search terms.
 JoVE General

Preparation of Cell-lines for Conditional Knockdown of Gene Expression and Measurement of the Knockdown Effects on E4orf4-Induced Cell Death


JoVE 4442 10/21/2012

Department of Molecular Microbiology, Faculty of Medicine, Technion - Israel Institute of Technology

Contribution of the ACF chromatin remodeling factor to E4orf4-induced cell death was measured. The protocol includes selection of cell clones in which doxycycline treatment induces conditional knockdown of the ACF subunits Acf1 and SNF2h, and use of the DAPI assay to measure E4orf4-induced cell death in the inducible cell lines.

Results below contain some, but not all of your search terms.
 JoVE Neuroscience

Intact Histological Characterization of Brain-implanted Microdevices and Surrounding Tissue


JoVE 50126 2/11/2013

1Weldon School of Biomedical Engineering, Purdue University, 2Department of Biological Sciences, Purdue University

Here we present a histological method for capturing, labeling, optically clearing, and imaging the intact brain tissue interface around chronically implanted microdevices in rodent brain tissue. Results from the techniques comprising this method are useful for understanding the impact of various penetrating brain-implants on their surrounding tissue.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Design of a Biaxial Mechanical Loading Bioreactor for Tissue Engineering


JoVE 50387 4/25/2013

1Department of Orthopaedics, The Warren Alpert Brown Medical School of Brown University and the Rhode Island Hospital, 2Center for Restorative and Regenerative Medicine, VA Medical Center, Providence, RI, 3University of Texas Southwestern Medical Center

We designed a novel mechanical loading bioreactor that can apply uniaxial or biaxial mechanical strain to a cartilage biocomposite prior to transplantation into an articular cartilage defect.

Results below contain some, but not all of your search terms.
 JoVE General

High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels


JoVE 4209 1/27/2013

1Department of Pharmacology, Vanderbilt University School of Medicine, 2Department of Anesthesiology, Vanderbilt University School of Medicine, 3Vanderbilt Institute of Chemical Biology, Vanderbilt University School of Medicine

Methods for developing and validating a quantitative fluorescence assay for measuring the activity of inward rectifier potassium (Kir) channels for high-throughput compound screening is presented.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Microfluidic Chip Fabrication and Method to Detect Influenza


JoVE 50325 3/26/2013

1Department of Mechanical Engineering, Boston University, 2Department of Biomedical Engineering, Boston University

An integrated microfluidic thermoplastic chip has been developed for use as a molecular diagnostic. The chip performs nucleic acid extraction, reverse transcriptase, and PCR. Methods for fabricating and running the chip are described.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE Clinical and Translational Medicine

Evaluation of Cancer Stem Cell Migration Using Compartmentalizing Microfluidic Devices and Live Cell Imaging


JoVE 3297 12/23/2011

1Department of Biomedical Engineering, University of Wisconsin-Madison, 2Materials Science Program, University of Wisconsin-Madison, 3Department of Neurological Surgery, University of Wisconsin-Madison, 4Carbone Comprehensive Cancer Center and Center for Stem Cell and Regenerative Medicine, University of Wisconsin-Madison

A compartmentalizing microfluidic device for investigating cancer stem cell migration is described. This novel platform creates a viable cellular microenvironment and enables microscopic visualization of live cell locomotion. Highly motile cancer cells are isolated to study molecular mechanisms of aggressive infiltration, potentially leading to more effective future therapies.

Results below contain some, but not all of your search terms.
 JoVE General

A Gradient-generating Microfluidic Device for Cell Biology


JoVE 271 8/30/2007

Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology; Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital

We describe a protocol for the microfabrication of the gradient-generating microfluidic device that can generate spatial and temporal gradients in well-defined microenvironment. In this approach, the gradient-generating microfluidic device can be used to study directed cell migration, embryogenesis, wound healing, and cancer metastasis.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Fabrication of Micropatterned Hydrogels for Neural Culture Systems using Dynamic Mask Projection Photolithography


JoVE 2636 2/11/2011

Biomedical Engineering, Tulane University

Simple techniques are described for the rapid production of microfabricated neural culture systems using a digital micromirror device for dynamic mask projection lithography on regular cell culture substrates. These culture systems may be more representative of natural biological architecture, and the techniques described could be adapted for numerous applications.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

A Microfluidic Device with Groove Patterns for Studying Cellular Behavior


JoVE 270 8/30/2007

Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology; Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital

We describe a protocol for the fabrication of microfluidic devices that can enable cell capture and culture. In this approach patterned microstructures such as grooves within microfluidic channels are used to create low shear stress regions within which cell can dock.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Simple Microfluidic Devices for in vivo Imaging of C. elegans, Drosophila and Zebrafish


JoVE 3780 9/30/2012

1Neurobiology, NCBS-TIFR, 2Department of Biological Sciences, TIFR

A simple microfluidic device has been developed to perform anesthetic free in vivo imaging of C. elegans, intact Drosophila larvae and zebrafish larvae. The device utilizes a deformable PDMS membrane to immobilize these model organisms in order to perform time lapse imaging of numerous processes such as heart beat, cell division and sub-cellular neuronal transport. We demonstrate the use of this device and show examples of different types of data collected from different model systems.

Results below contain some, but not all of your search terms.
 JoVE General

In vivo Imaging of Intact Drosophila Larvae at Sub-cellular Resolution


JoVE 2249 9/10/2010

1Junior Research Group Synaptic Plasticity, Hertie Institute for Clinical Brain Research, University of Tübingen, 2Graduate School of Cellular and Molecular Neuroscience, University of Tübingen

This protocol describes a reliable method for anesthetization and imaging of intact Drosophila melanogaster larvae. We have utilized the volatile anesthetic desflurane to allow for repetitive imaging at sub-cellular resolution and re-identification of structures for up to a few days1.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Creating Adhesive and Soluble Gradients for Imaging Cell Migration with Fluorescence Microscopy


JoVE 50310 4/04/2013

1Centre for Vascular Research and Australian Centre for Nanomedicine, The University of New South Wales, 2School of Chemistry and Australian Centre for Nanomedicine, The University of New South Wales

A method for the assembly of adhesive and soluble gradients in a microscopy chamber for live cell migration studies is described. The engineered environment combines antifouling surfaces and adhesive tracks with solution gradients and therefore allows one to determine the relative importance of guidance cues.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Biosensor for Detection of Antibiotic Resistant Staphylococcus Bacteria


JoVE 50474 5/08/2013

1Department of Anatomy, Physiology and Pharmacology, College of Veterinary Medicine, Auburn University, 2Clinical Research Laboratory, 81st Medical Group, Keesler Air Force Base

Lytic phage biosensors and antibody beads are able to discriminate between methicillin resistant (MRSA) and sensitive staphylococcus bacteria. The phages were immobilized by a Langmuir-Blodgett method onto a surface of a quartz crystal microbalance sensor and worked as broad range staphylococcus probes. Antibody beads recognize MRSA.

Results below contain some, but not all of your search terms.
 JoVE General

Non-plasma Bonding of PDMS for Inexpensive Fabrication of Microfluidic Devices


JoVE 410 11/01/2007

1Department of Biomedical Engineering, University of California, Irvine (UCI), 2Stem Cell Research Center, University of California, Irvine (UCI), 3Institute for Brain Aging and Dementia, University of California, Irvine (UCI)

In this video we demonstrate how to use the neuron microfluidic device without plasma bonding.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

A Microfluidic Device for Quantifying Bacterial Chemotaxis in Stable Concentration Gradients


JoVE 1779 4/19/2010

1McFerrin Department of Chemical Engineering, Texas A&M University, 2Department of Biology, Texas A&M University, 3Department of Biomedical Engineering, Texas A&M University

This protocol describes the development of a microfluidic device for investigating bacterial chemotaxis in stable concentration gradients of chemoeffectors.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

Fabrication of a Microfluidic Device for the Compartmentalization of Neuron Soma and Axons


JoVE 261 8/22/2007

1Department of Biomedical Engineering, University of California, Irvine (UCI), 2Stem Cell Research Center, University of California, Irvine (UCI), 3Institute for Brain Aging and Dementia, University of California, Irvine (UCI)

In this video we demonstrate the technique of soft lithography with polydimethyl siloxane (PDMS) which we use to farbricate a microfluidic device for culturing neurons.

Results below contain some, but not all of your search terms.
 JoVE General

Microfluidic Co-culture of Epithelial Cells and Bacteria for Investigating Soluble Signal-mediated Interactions


JoVE 1749 4/20/2010

1McFerrin Department of Chemical Engineering, Texas A&M University, 2Department of Biomedical Engineering, Texas A&M University

This protocol describes a microfluidic co-culture model for simultaneous and localized culture of epithelial cells and bacteria. This model can be used for investigating the role of different soluble molecular signals on pathogenesis as well as screen the effectiveness of putative probiotic bacterial strains.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

Identifying Targets of Human microRNAs with the LightSwitch Luciferase Assay System using 3'UTR-reporter Constructs and a microRNA Mimic in Adherent Cells


JoVE 3343 9/28/2011

SwitchGear Genomics

MicroRNAs (miRNAs) are important regulators of gene expression and have been shown to play a role in numerous biological processes. To better understand miRNA-UTR interactions, we have created a genome-wide collection of 3 UTR luciferase reporters paired with a novel luciferase gene and assay reagent, the LightSwitch system.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE Clinical and Translational Medicine

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants


JoVE 4379 3/14/2013

1Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 2Lab. PALM, Université de Caen Basse-Normandie, 3Fetal-Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Harvard Medical School, 4ISS, INC.

We combined frequency-domain near-infrared spectroscopy measures of cerebral hemoglobin oxygenation with diffuse correlation spectroscopy measures of cerebral blood flow index to estimate an index of oxygen metabolism. We tested the utility of this measure as a bedside screening tool to evaluate the health and development of the newborn brain.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Graphene Coatings for Biomedical Implants


JoVE 50276 3/01/2013

1Department of Physics, Clemson University, 2Department of Pharmacology and Toxicology, East Carolina University, 3Department of Bioengineering, Clemson University, 4Center for Optical Materials Science and Engineering Technologies, Clemson University

Graphene offers potential as a coating material for biomedical implants. In this study we demonstrate a method for coating nitinol alloys with nanometer thick layers of graphene and determine how graphene may influence implant response.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone


JoVE 50451 4/11/2013

1Electrical Engineering Department, University of California, Los Angeles, 2Bioengineering Department, University of California, Los Angeles, 3California NanoSystems Institute (CNSI), University of California, Los Angeles

We review our recent results on the integration of fluorescent microscopy and imaging flow cytometry tools on a cell-phone using compact and cost-effective opto-fluidic attachments. These cell-phone based micro-analysis devices might be useful for cytometric analysis, such as performing various cell counting tasks as well as for high-throughput screening of e.g., water samples in resource limited settings.

Results below contain some, but not all of your search terms.
 JoVE Immunology and Infection

Expanding Cytotoxic T Lymphocytes from Umbilical Cord Blood that Target Cytomegalovirus, Epstein-Barr Virus, and Adenovirus


JoVE 3627 5/07/2012

1Center for Cell and Gene Therapy, Baylor College of Medicine, 2Pathology and Immunology, Baylor College of Medicine, 3Department of Stem Cell Transplantation and Cellular Therapy, University of Texas M.D. Anderson Cancer Center, 4Medicine, Baylor College of Medicine, 5Department of Pediatrics, Baylor College of Medicine

Here we describe the first good manufacturing practice (GMP)-compliant method of producing virus-specific cytotoxic T lymphocytes (CTL) from umbilical cord blood, a source of predominantly naîve T cells.

Results below contain some, but not all of your search terms.
 JoVE Immunology and Infection

piggyBac Transposon System Modification of Primary Human T Cells


JoVE 4235 11/05/2012

1Program in Translational Biology and Molecular Medicine, Baylor College of Medicine, 2Department of Medicine, Division of Nephrology, Baylor College of Medicine, 3Department of Immunology and Pathology, Shinshu University School of Medicine, 4Center for Cell and Gene Therapy, Baylor College of Medicine, 5Department of Pediatrics, Baylor College of Medicine, 6Program in Cell and Molecular Biology, Baylor College of Medicine, 7Department of Molecular Virology and Microbiology, Baylor College of Medicine, 8Michael E. DeBakey VA Medical Center

We describe a method to genetically modify primary human T cells with a transgene using the non-viral piggyBac transposon system. T cells modified to using the piggyBac transposon system exhibit stable transgene expression.

Results below contain some, but not all of your search terms.
 JoVE Neuroscience

Laser Capture Microdissection of Drosophila Peripheral Neurons


JoVE 2016 5/24/2010

1Department of Molecular and Microbiology, George Mason University, 2Krasnow Institute for Advanced Study, George Mason University

In this video-article we present a method for isolating single or multiple Drosophila da neurons from third instar larvae using the infrared capture (IR) class of Laser Capture Microdissection (LCM). RNA obtained from the isolated neurons can be readily used for downstream applications including qRT-PCR or microarray analyses.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

Recapitulation of an Ion Channel IV Curve Using Frequency Components


JoVE 2361 2/08/2011

Bioengineering, University of Utah

There are technical obstacles to measuring current flux through multiple ion channels simultaneously, and later discerning what portion of the transmembrane current is due to each channel type. To address this need, this method presents a way to generate the IV curve of individual channel types using specific frequency components.

Results below contain some, but not all of your search terms.
 JoVE General

Preparation of Aplysia Sensory-motor Neuronal Cell Cultures


JoVE 1355 6/08/2009

1Dept. of Psychiatry and Biobehavioral Sciences, University of California, Los Angeles, 2Dept. of Biological Chemistry, University of California, Los Angeles, 3Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles

Primary cultures of Aplysia sensory-motor neurons provide a model preparation for studying synapse formation and synaptic plasticity in vitro. This video demonstrates the identification and microdissection of sensory and motor neurons from Aplysia ganglia as well as the methods for establishing and maintaining sensory-motor neurons in culture.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Endothelialized Microfluidics for Studying Microvascular Interactions in Hematologic Diseases


JoVE 3958 6/22/2012

1Department of Pediatrics, Emory University School of Medicine, 2Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 3Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, 4Winship Cancer Institute of Emory University

A method to culture an endothelial cell monolayer throughout the entire inner 3D surface of a microfluidic device with microvascular-sized channels (<30 μm) is described. This in vitro microvasculature model enables the study of biophysical interactions between blood cells, endothelial cells, and soluble factors in hematologic diseases.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Autologous Endothelial Progenitor Cell-Seeding Technology and Biocompatibility Testing For Cardiovascular Devices in Large Animal Model


JoVE 3197 9/09/2011

1Department of Biomedical Engineering, Duke University, 2School of Medicine, Duke University, 3Department of Surgery, Duke University Medical Center, 4School of Medicine, University of Pennsylvania

A method for seeding titanium blood-contacting biomaterials with autologous cells and testing biocompatibility is described. This method uses endothelial progenitor cells and titanium tubes, seeded within minutes of surgical implantation into porcine venae cavae. This technique is adaptable to many other implantable biomedical devices.

Results below contain some, but not all of your search terms.
 JoVE General

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices


JoVE 1329 9/02/2009

1Materials Science Program, University of Wisconsin-Madison, 2Department of Biomedical Engineering, University of Wisconsin-Madison

A novel microfluidic system has been developed using the phenomenon of passive pumping and a user controlled fluid delivery system. This microfluidic system has the potential to be used in a wide variety of biological applications given its low cost, ease of use, volumetric precision, high speed, repeatability and automation.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Rapid Isolation of Viable Circulating Tumor Cells from Patient Blood Samples


JoVE 4248 6/15/2012

1Department of Biomedical Engineering, Cornell University, 2BioCytics, Inc., 3Carolina BioOncology Institute, PLLC

Circulating tumor cells are isolated from the blood of cancer patients without inflicting cellular damage. Isolation of tumor cells is accomplished using a bimolecular surface of E-selectin in addition to antibodies against epithelial markers. A nanotube coating specifically promotes cancer cell adhesion resulting in high capture purities.

Results below contain some, but not all of your search terms.
Results below contain some, but not all of your search terms.
 JoVE General

Silicon Microchips for Manipulating Cell-cell Interaction


JoVE 268 8/30/2007

Laboratory for Multiscale Regenerative Technologies, MIT - Massachusetts Institute of Technology

This article describes an experimental approach for dynamic regulation of cell-cell interactions between adherent cells on a micrometer scale. Manipulation of intercellular communication between hepatocytes and stromal cell is demonstrated. The developed platform enables investigation of cell-cell interactions in a variety of biological processes, including development and pathogenesis.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Microfabricated Platforms for Mechanically Dynamic Cell Culture


JoVE 2224 12/26/2010

1Department of Mechanical and Industrial Engineering, University of Toronto, 2Institute of Biomaterials and Biomedical Engineering, University of Toronto, 3Faculty of Dentistry, University of Toronto

In this protocol, we demonstrate the fabrication of a microactuator array of vertically displaced posts on which the technology is based, and how this base technology can be modified to conduct high-throughput mechanically dynamic cell culture in both two-dimensional and three-dimensional culture paradigms.

Results below contain some, but not all of your search terms.
 JoVE General

A Multi-compartment CNS Neuron-glia Co-culture Microfluidic Platform


JoVE 1399 9/10/2009

1Department of Electrical and Computer Engineering, Texas A&M University (TAMU), 2Department of Veterinary Integrative Biosciences, Texas A&M University (TAMU)

We developed a novel multi-compartment neuron co-culture microsystem platform for in vitro CNS axon-glia interaction research. The platform is capable of conducting up to six independent experiments in parallel and was fabricated using a newly developed macro/micro hybrid fabrication method.

Results below contain some, but not all of your search terms.
 JoVE Neuroscience

Investigations on Alterations of Hippocampal Circuit Function Following Mild Traumatic Brain Injury


JoVE 4411 11/19/2012

1Division of Neurology, Children's Hospital of Philadelphia, 2Neuroscience Graduate Group, Perelman School of Medicine at the University of Pennsylvania, 3Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania

A multi-faceted approach to investigating functional changes to hippocampal circuitry is explained. Electrophysiological techniques are described along with the injury protocol, behavioral testing and regional dissection method. The combination of these techniques can be applied in similar fashion for other brain regions and scientific questions.

Results below contain some, but not all of your search terms.
 JoVE General

Window on a Microworld: Simple Microfluidic Systems for Studying Microbial Transport in Porous Media


JoVE 1741 5/03/2010

1Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, 2Department of Biomedical Engineering, Vanderbilt University, 3Department of Molecular Physiology and Biophysics, Vanderbilt University, 4Department of Physics and Astronomy, Vanderbilt University, 5Department of Chemical, Materials and Biomolecular Engineering, University of Connecticut, 6Center for Environmental Sciences and Engineering, University of Connecticut

Microfluidic devices can be used to visualize complex natural processes in real time and at the appropriate physical scales. We have developed a simple microfluidic device that mimics key features of natural porous media for studying growth and transport of bacteria in the subsurface.

Results below contain some, but not all of your search terms.
 JoVE Bioengineering

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow


JoVE 2545 2/04/2011

1Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 2Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, 3Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 4Bioengineering, University of Illinois at Urbana-Champaign

Dielectrophoresis (DEP) is an effective method to manipulate cells. Printed circuit boards (PCB) can provide inexpensive, reusable and effective electrodes for contact-free cell manipulation within microfluidic devices. By combining PDMS-based microfluidic channels with coverslips on PCBs, we demonstrate bead and cell manipulation and separation within multichannel microfluidic devices.

More Results...
Waiting
simple hit counter