Abdominal wall defects often arise following severe trauma, cancer treatment, burns and removal of infected mesh. These defects often involve significant tissue loss, requiring complicated surgical procedures and presenting a major challenge for plastic reconstruction surgeons 1-4. Tissue engineering researchers seeking new sources for artificial tissues have explored different materials, cell sources and growth factors. Successful restorations of various tissues, such as trachea 5,6, bladder 7, cornea 8, bone 9and skin 10, by implantation of engineered tissues were previously reported. However, fabrication of a thick vascularized engineered tissue, particularly for reconstruction of large defects, remains a significant challenge in tissue engineering.
One of the main factors limiting the thickness of a viable tissue construct is the control of oxygen supply to its constituent cells. When relying on diffusion, construct thickness is limited to that of a very thin layer. The maximum distance between oxygen- and nutrient-supplying capillaries in vivo is approximately 200 µm, which correlates with the diffusion limit of oxygen11,12. Insufficient vascularization can result in tissue ischemia and escalate to tissue resorption or necrosis 13.
In addition, the ideal material used for tissue reconstruction must be biocompatible and non-immunogenic. It must also be capable of promoting further integration of host cells with the biomaterial, and maintaining structural integrity. Various biological 14-16 and synthetic 1,17,18 matrices have been previously explored for tissue reconstruction, however their use remain limited due to lack of effective blood supply, infections or insufficient tissue strength.
In this study, a biocompatible, cell-embedded scaffold comprised of Food and Drug Administration (FDA)-approved poly L-lactic acid (PLLA)/poly lactic-co-glycolic acid (PLGA), was implanted around the femoral artery and vein (AV) vessels of a nude mouse and separated from the surrounding tissue, ensuring vascularization from the AV vessels only. One week post-implantation, the graft was viable, thick and well vascularized. This thick vascularized tissue with the AV vessels, was then transferred as a pedicled flap to an abdominal full-thickness defect in the same mouse. One week post-transfer, the flap was viable, vascularized and well integrated with the surrounding tissue, bearing sufficient strength to support abdominal viscera. Thus, the engineered thick, vascularized tissue flap, bearing an autologous pedicle, presents a novel method for repairing full-thickness abdominal wall defects.