Sequential Application of Glass Coverslips to Assess the Compressive Stiffness of the Mouse Lens: Strain and Morphometric Analyses

7K views

⸱

DOI:

10.3791/53986

⸱

May 3rd, 2016

 ,  ,  , 

In This Article

Summary

Age-related increases in eye lens stiffness are linked to presbyopia. This protocol describes a simple, cost-effective method for measuring mouse lens stiffness. Mouse lenses, like human lenses, become stiffer with age. This method is precise and can be adapted for lenses from larger animals.

Abstract

The eye lens is a transparent organ that refracts and focuses light to form a clear image on the retina. In humans, ciliary muscles contract to deform the lens, leading to an increase in the lens' optical power to focus on nearby objects, a process known as accommodation. Age-related changes in lens stiffness have been linked to presbyopia, a reduction in the lens' ability to accommodate, and, by extension, the need for reading glasses. Even though mouse lenses do not accommodate or develop presbyopia, mouse models can provide an invaluable genetic tool for understanding lens pathologies, and the accelerated aging observed in mice enables the study of age-related changes in the lens. This protocol demonstrates a simple, precise, and cost-effective method for determining mouse lens stiffness, using glass coverslips to apply sequentially increasing compressive loads onto the lens. Representative data confirm that mouse lenses become stiffer with age, like human lenses. This method is highly reproducible and can potentially be scaled up to mechanically test lenses from larger animals.

Introduction

The lens is a transparent and avascular organ in the anterior chamber of the eye that is responsible for fine focusing of light onto the retina. A clear basement membrane, called the lens capsule, surrounds a bulk of elongated fiber cells covered by an anterior monolayer of epithelial cells1,2. Life-long growth of the lens depends on the continuous proliferation and differentiation of epithelial cells at the lens equator into new fiber cells that are added onto previous generations of fiber cells in a concentric manner2. Over time, lens fiber cells undergo compaction, resulting in a rigid center in the middle of the lens called the nucleus1<....

Access restricted. Please log in or start a trial to view this content.

Protocol

All animal procedures were performed in accordance with recommendations in the Guide for the Care and Use of Laboratory Animals by the National Institutes of Health and under an approved protocol by the Institutional Animal Care and Use Committee at The Scripps Research Institute.

1. Lens Dissection

  1. Euthanize mice according to recommendations in the National Institutes of Health "Guide for the Care and Use of Laboratory Animals" and approved institution animal use protocols. 
  2. Enucleate the eye from mice using curved forceps. Depress the tissue around the eye with the forceps to bring the eye out of the socket, and then....

Access restricted. Please log in or start a trial to view this content.

Results

The stiffness and dimensions of 2-, 4- and 8-month-old mouse lenses were measured. Mice were all wild-type animals on a pure C57BL6 strain background obtained from the TSRI Animal Breeding Facility, and each lens was loaded with 1 to 10 coverslips. The axial and equatorial strains were calculated as a function of applied load by measuring the axial and equatorial diameters of the lens after the addition of each coverslip, and then normalizing each change in diameter to the corresponding u.......

Access restricted. Please log in or start a trial to view this content.

Discussion

There are several key considerations when using this method to measure lens stiffness. First, the coverslips are applied to the lens at a slightly oblique angle (8 - 8.5°) with respect to the bottom of the chamber (θ). This will apply a very small component of the load equatorially rather than axially. However, this equatorial load is considered negligible because sin θ ≈ 0.119. If this method is adapted for larger lenses, the angle of the coverslips to the bottom of the chamber would need.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported by National Eye Institute Grant R01 EY017724 (VMF) and National Institute of Arthritis and Musculoskeletal and Skin Diseases Grant K99 AR066534 (DSG).

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Fine tip straight forcepsFine Scientific Tools11252-40
Microdissection scissors, straight edgeFine Scientific Tools15000-00
Curved forcepsFine Scientific Tools11272-40
Seizing forcepsHammacherHSC 702-93Optional
Dissection dishFisher Scientific12565154
60 mm Petri dishFisher Scientific0875713A
1x phosphate buffered saline (PBS)Life Technologies14190
18 x 18 mm glass coverslipsFisher Scientific12-542A
Measurement chamber with divots to hold lensesCustom-made (see Figure 1)
Right-angle mirrorEdmund Optics45-591
Light sourceSchott/Fostec8375
Illuminated dissecting microscopeOlympusSZX-ILLD100With SZ-PT phototube
Digital cameraNikonCoolpix 990

References

  1. Lovicu, F. J., Robinson, M. L. Development of the ocular lens. , Cambridge University Press. (2004).
  2. Piatigorsky, J. Lens differentiation in vertebrates. A review of cellular and molecular features. Differentiation. 19 (3), 134-153 (1981).
  3. Glasser, A.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Mouse Lens StiffnessLens DissectionMorphometric AnalysisStrain MeasurementPBS ChamberDissecting MicroscopeImage AnalysisLens Nucleus