| 4T1 cell line | American Type Culture Collection, Manassas, VA, USA | CRL 2539 | Tumor cells |
|---|
| 4T1-GFP cell line | Caliper life sciences/ Perkin Elmer, Waltham, MA, USA | BW128090 | Tumor cells |
|---|
| RPMI | Corning, Corning, NY, USA | 10-040-CM | Media |
|---|
| Heat inactivated FBS | Gibco (Thermo Scientific), USA | 10082147 | Media |
|---|
| Penicillin Streptomycin | Fisher Scientific, Waltham, MA, USA | MT-300-02-CI | Media |
|---|
| PBS | Fisher Scientific, Waltham, MA, USA | BP399-20 | Dilute with distilled water |
|---|
| Trypsin 0.25% with EDTA | Hyclone, Logan, Utah, USA | SH30042.02 | Tissue culture supplies |
|---|
| T75 cm2 flask | Fisher Scientific, Waltham, MA, USA | 12-565-32 | Tissue culture supplies |
|---|
| 15 ml conical tube | BD falcon, Franklin Lakes, NJ, USA | 352096 | Tissue culture supplies |
|---|
| 50 ml conical tube | BD falcon, Franklin Lakes, NJ, USA | 352098 | Tissue culture supplies |
|---|
| 60 mm2 Petri dish | Fisher Scientific, Waltham, MA, USA | AS4052 | For lung imaging |
|---|
| Isoflurane (Isothesia) | Butler Schein Animal health, Dublin, OH, USA | NDC 11695-6776-2 | Mouse anesthesia |
|---|
| Clodronate liposomes | Formumax Scientific Inc, Palo Alto, CA, USA | F70101C-N | Macrophages depletion |
|---|
| Control liposomes | Formumax Scientific Inc, Palo Alto, CA, USA | F70101-N | Control PBS-liposomes |
|---|
| 29 gauge insulin syringes (12.7 mm and 0.5 ml capacity)- Reli-On | Walmart, Bentonville, AR, USA | | For tumor cell injection |
|---|
| Hair removal cream (Nair) | Walmart, Bentonville, AR, USA | | |
|---|
| Paraformaldehyde solution (4%) | Affymetrix, Santa Clara, CA, USA | 19943-I Lt | Dilute to 4% or 1% using 1x PBS |
|---|
| OCT compound | Fisher Scientific, Waltham, MA, USA | 230-730-571 | For freezing tissue in cryomolds |
|---|
| Fluoro-Gel-II with DAPI | Electron Microscopy Sciences, Hatfield, PA, USA | 17985-51 | Mounting medium |
|---|
| Sucrose | Sigma, St. Louis, MO, USA | S-9378 | Cryopreservation |
|---|
| Collagenase P | Roche, Basel, Switzerland | 11249002001 | Components of tissue digestion buffer |
|---|
| Dnase I | Roche, Basel, Switzerland | 10104159001 | Components of tissue digestion buffer |
|---|
| Trypsin inhibitor | Sigma, St. Louis, MO, USA | T9253 | Components of tissue digestion buffer |
|---|
| 40 micron cell strainers | Fisher Scientific, Waltham, MA, USA | 22-363-547 | Used in tissue digestion to remove clumps |
|---|
| Trustain FcX-Fc Block (CD16/CD32) | Biolegend, San Diego, CA, USA | 101320 | Antibodies for flow cytometry |
|---|
| BV605 CD45 | Biolegend, San Diego, CA, USA | 103139 | Antibodies for flow cytometry |
|---|
| PE CD11b | Biolegend, San Diego, CA, USA | 101207 | Antibodies for flow cytometry |
|---|
| PE Cy7 F4/80 | Biolegend, San Diego, CA, USA | 123113 | Antibodies for flow cytometry |
|---|
| APC/Cy7 CD11c | Biolegend, San Diego, CA, USA | 117323 | Antibodies for flow cytometry |
|---|
| PerCPcy5.5 IA/IE (MHCII) | Biolegend, San Diego, CA, USA | 107625 | Antibodies for flow cytometry |
|---|
| PE CD80 | Biolegend, San Diego, CA, USA | 104707 | Antibodies for flow cytometry |
|---|
| AF647 CD86 | Biolegend, San Diego, CA, USA | 105019 | Antibodies for flow cytometry |
|---|
| Fixable viability Dye eflour 506 | eBioscience, San Diego, CA,USA | 65-0866 | Antibodies for flow cytometry |
|---|
| Cryostat | Leica Biosystems, Buffalo Grove, IL, USA | CM1850 | Cryosectioning |
|---|
| UVP iBox Explorer | UVP Inc, Upland, CA, USA | | Mouse and lung fluorescent imaging |
|---|
| Aperio Scanscope CS | Leica Biosystems, Buffalo Grove, IL, USA | | Digital pathology |
|---|
| BD LSRFortessa | BD Biosciences, Franklin Lakes, NJ, USA | | Flow cytometry/data acquisition |
|---|
| Nikon A1 confocal TE2000 microscope | Nikon Instruments Inc., Melville, NY 11747-3064, U.S.A. | | Imaging and quantifying GFP fluorescence in lung cryosections |
|---|
| UVP visionworks software (Version 7.1RC3.38) | UVP Inc, Upland, CA, USA | | Imaging software for iBOX |
|---|
| Aperio Imagescope software (v12.1.0.5029) | Leica Biosystems, Buffalo Grove, IL, USA | | Imaging software for analysis of digital slides |
|---|
| Flow JO software (version 9.8.1) | Flow JO LLC, Ashland, OR, USA | | Analysis of flow cytometric data |
|---|
| NIS Elements AR (version 4.20.01) 64 Bit | Nikon Instruments Inc., Melville, NY 11747-3064, U.S.A. | | Acquisition and analysis of lung cryosections for GFP |
|---|