A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

In Situ Monitoring of Diffusion of Guest Molecules in Porous Media Using Electron Paramagnetic Resonance Imaging

5.9K views

⸱

DOI:

10.3791/54335

⸱

September 2nd, 2016

 ,  , 

In This Article

Summary

A protocol for the in situ monitoring of the diffusion of guest molecules in porous media using electron paramagnetic resonance (EPR) imaging is presented.

Abstract

A method is demonstrated to monitor macroscopic translational diffusion using electron paramagnetic resonance (EPR) imaging. A host-guest system with nitroxide spin probe 3-(2-Iodoacetamido)-2,2,5,5-tetramethyl-1-pyrrolidinyloxy (IPSL) as a guest inside the periodic mesoporous organosilica (PMO) aerogel UKON1-GEL as a host and ethanol as a solvent is used as an example to describe the protocol. Data is shown from a previous publication, where the protocol has been applied to both IPSL and Tris(8-carboxy-2,2,6,6-perdeutero-tetramethyl-benzo[1,2-d:4,5-d′]bis(1,3)dithiole) methyl (Trityl) as guest molecules and UKON1-GEL and SILICA-GEL as host systems.

A method is shown to prepare aerogel samples that cannot be synthesized directly in the sample tube for measurement due to a size change during synthesis. The aerogel is attached to sample tubes using heat shrink tubing and a pressure cooker to reach the necessary temperature without evaporating the solvent in the process. The method does not assume a clearly defined initial distribution of guest molecules at the start of the measurement. Instead, it requires a reservoir on top of the aerogel and experimentally determines the influx rate during data analysis.

The diffusion is monitored continually over a period of 20 hr by recording the 1d spin density profile within the sample. The spectrometer settings for the imaging experiment are described quantitatively. Data analysis software is provided to take the resonator sensitivity profile into account and to numerically solve the diffusion equation. The software determines the macroscopic translational diffusion coefficient by least square minimization of the difference between the experiment and the numerical solution of the diffusion equation.

Introduction

Porous materials play a major role in practical applications such as catalysis and chromatography1. By adding surface groups and adjusting the pore size and surface properties, the materials can be tailored to the desired application2,3. The functionality of the porous material crucially depends on the diffusion properties of the guest molecules inside the pores. In porous materials, a distinction must be made between the microscopic translational diffusion constant D​micro, which describes diffusion on a molecular length scale on one hand and the macroscopic translational diffusion constant Dmacro....

Access restricted. Please log in or start a trial to view this content.

Protocol

Caution: Please consult all relevant material safety data sheets (MSDS) before use. Ethanol is harmful if swallowed or inhaled and it is flammable.

1. Optimize the Continuous Wave (CW) EPR Parameters

  1. Prepare 40 µl of IPSL in ethanol (p.a.) at a concentration of 1 mM.
  2. Take a pipette controller and fill a capillary with the IPSL solution to a filling height of 2 cm. Pull the solution 1 cm further into the capillary so that there is an air gap below the solution. Seal the capillary on both ends with capillary tube sealing compound. The air gap prevents diffusion of components of the sealing compound into the sample.
  3. ....

Access restricted. Please log in or start a trial to view this content.

Results

A photo and schematic of an aerogel within the shrinking tube is shown in Figures 2a and 2b. The 2d EPR image in Figure 2c clearly shows the upper edge of the aerogel. The intensity of ρ1d within the sample tube above the aerogel is lower although the concentration of the spin probe is at least as high as within the aerogel. However, the sample depth perpendicular to the picture plane is much smaller due to the smaller.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The protocol allows monitoring of the diffusion of paramagnetic guest molecules. A 1d imaging approach has been chosen because it allows for a higher time resolution compared to 2d or 3d imaging. The 1d approach requires a constant cross sectional area of the sample because the intensity of the obtained 1d image depends not only on the concentration but also on the cross sectional area of the sample. The method also requires that the EPR spectra of the spin probes within the samples only change in intensity but not in sh.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

The authors thank Prof. Peter Imming and Diana Müller for synthesis of the Trityl spin probe and Prof. Sebastian Polarz, Martin Wessig and Andreas Schachtschneider for the synthesis of the porous materials. Financial support by the DFG (DR 743/7-1) and within the SPP 1570 is gratefully acknowledged.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
X-Band spectrometerBrukerE580
Spectrometer softwareBrukerXepr 2.6b.108
gradient coil systemBrukerE540 GCX2
imaging resonatorBrukerTMHS 1007
micro-classic pipette controllerBrand25900
microcapillary ringcaps 50 µlHirschmann9600150inner diameter 0.5 mm
EPR sample tube 2 mm inner diameterBrukerER 221TUB/2
EPR sample tube 4 mm inner diameterBrukerER 221TUB/4
heat-shrink tubing DERAY-IBDSG-Canusa22100489524.8 mm/2.4 mm, 2:1, 95 °C - 200 °C
heat gunBoschPHG 600-3
PTFE  bandVWR332362Swidth 12 mm
test tubelength 16 cm, diameter 1.5 cm
beaker250 ml, height 9 cm, diameter 7 cm
capillary tube sealingFisher Scientific02-678
pressure cooker, 3 L with trivetBeemVital-X-Press V2, F1000675
magnetic stirrer with heating element
ethanol (p.a.)
ethanol (techn.)
syringeHamilton17050.05 ml, custom length: 20 cm
Pasteur capillary pipettelength 23 cm
data analysis softwarehomemadeAvailable for download at http://www.uni-konstanz.de/drescher/software. Requires Matlab.
UKON1-GELkindly provided by Prof. Sebastian Polarz, Martin Wessig and Andreas Schachtschneider See references 16, 18, 19 for the synthesis

References

  1. Schüth, F., Sing, K. S. W., Weitkamp, J. Handbook of Porous Solids. , Wiley-VCH Verlag GmbH. Weinheim, Germany. (2002).
  2. Hoffmann, F., Cornelius, M., Morell, J., Fröba, M. Silica-Based Mesoporous Organic-Inorganic Hybrid Materials. Angew. Chem. Int. Edit. 45 (20), 3216-3251 (2006).
  3. Sanchez, C., Boissière, C., ....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Diffusion MonitoringAerogel Sample PreparationHeat Shrink TubingPressure Cooker MethodSpin Density ProfileDiffusion Coefficient AnalysisEPR Imaging Experiment