Method Article

Lipidico Injection Protocol for Serial Crystallography Measurements at the Australian Synchrotron

3K views

⸱

DOI:

10.3791/61650

⸱

September 23rd, 2020

 ,  ,  ,  , 

In This Article

Summary

The goal of this protocol is to demonstrate how to prepare serial crystallography samples for data collection on a high viscous injector, Lipidico, recently commissioned at the Australian synchrotron.

Abstract

A facility for performing serial crystallography measurements has been developed at the Australian synchrotron. This facility incorporates a purpose built high viscous injector, Lipidico, as part of the macromolecular crystallography (MX2) beamline to measure large numbers of small crystals at room temperature. The goal of this technique is to enable crystals to be grown/transferred to glass syringes to be used directly in the injector for serial crystallography data collection. The advantages of this injector include the ability to respond rapidly to changes in the flow rate without interruption of the stream. Several limitations for this high viscosity injector (HVI) exist which include a restriction on the allowed sample viscosities to >10 Pa.s. Stream stability can also potentially be an issue depending on the specific properties of the sample. A detailed protocol for how to set up samples and operate the injector for serial crystallography measurements at the Australian synchrotron is presented here. The method demonstrates preparation of the sample, including the transfer of lysozyme crystals into a high viscous media (silicone grease), and the operation of the injector for data collection at MX2.

Introduction

Serial crystallography (SX) is a technique that was developed initially in the context of X-ray Free Electron Lasers (XFELs)1,2,3,4. Though fixed target approaches can be used for SX5,6,7, typically, injector systems are employed to deliver crystals in a continuous stream to the X-ray beam. Because it combines data from a large number of crystals, SX avoids the need for any crystal alignment during the experiment, and enables data to be collected at....

Access restricted. Please log in or start a trial to view this content.

Protocol

1. Preparation of crystals in a high viscous media using glass syringes

  1. Centrifuge the crystal solution gently (~1,000 x g, ~10 min at 22 °C) to form a soft crystal pellet and remove the excess buffer. This will result in a high concentration of crystals in the pellet which can be used for data collection.
    NOTE: To prevent dilution of the viscous media increase the crystal concentration at this step. Optimize the ratio of viscous media to crystal volume for each sample to obtain a high concentration of crystals whilst maintaining a high viscosity for the media. Centrifuge the crystal solution to form a pellet and remove excess buffer t....

Access restricted. Please log in or start a trial to view this content.

Results

Lipidico is an HVI built as an alternative delivery system for use on MX2 (Figure 1). It is ideally suited for SX where crystals are either grown in lipidic cubic phase or transferred to a high viscous inert media.

To demonstrate the injector application silicone grease mixed with lysozyme crystals was used to collect SX data at the MX2 beamline at the Australian synchrotron. To mount the injector on the MX2 beamline the cryogenic nozzle is removed and replaced by.......

Access restricted. Please log in or start a trial to view this content.

Discussion

An alternative HVI has been developed, ideal for carrying out SX experiments at synchrotron sources. It has two key advantages over existing HVIs. First, it is easy to install on the beamline allowing rapid switching between conventional crystallography and SX, just ~30 minutes is required for installation and alignment on MX2. Second, the sample syringes used to grow crystals can be directly used as the reservoirs for injection, limiting wastage during sample transfer. The protocol for changing samples has been des.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

MK works for Kusel designs. Kusel Design, a custom laboratory device developer, was engaged by Dr Peter Bentsen of La Trobe University and Dr Tom Caradoc-Davies of ANSTO and to develop a low-cost device to enable high viscous studies in the MX2 beam line at the Australian Synchrotron. The device was developed in close consultation with Dr. Caradoc-Davies. The authors have no competing financial interests.

Acknowledgements

This work was supported by the Australian Research Council Centre of Excellence in Advanced Molecular Imaging (CE140100011) (http://www.imagingcoe.org/). This research was undertaken in part using the MX2 beamline at the Australian Synchrotron, part of ANSTO, and made use of the Australian Cancer Research Foundation (ACRF) detector.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Hen eggwhite lysozymeSigma-AldrichL6876Used to grow crystals for testing the injector and the crystals are transferred into silicon grease. https://www.sigmaaldrich.com/
High vacuum silicon greaseDow CorningZ273554-1EAUsed for testing of injector. https://www.sigmaaldrich.com/
Injector needle (108 µm ID)Hamiltonpart No: 7803-05www.hamiltoncompany.com
Glass gas-tight syringes, 100 µlHamiltonpart no: 7656-01Syringes used for sample injection. www.hamiltoncompany.com
LCP syringe couplerFormulatrix209526Syringe coupler to mix the samples
Lipidico injectorLa Trobe Univerity/ANSTOThis is a specific piece of equipment that can be accessed through La Trobe University / ANSTO Australian Synchrotron Facility

References

  1. Boutet, S., et al. High-resolution protein structure determination by serial femtosecond crystallography. Science. 337 (6092), 362-364 (2012).
  2. Spence, J. C. H., Weierstall, U., Chapman, H. N. X-ray lasers for structural and dynamic biology. Reports on Pro....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Lipidico InjectorHigh Viscous MediaGlass Syringe SetupCrystal ConcentrationFlow Rate ControlSample PreparationViscosity MeasurementElectron Density Map