Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove
Experiment
JoVE Encyclopedia of Experiments
Encyclopedia of Experiments: Biological Techniques

A subscription to JoVE is required to view this content.

 

Single-Cell Western Blotting to Determine Cell Heterogeneity

Article

Transcript

For a single-cell Western blot analysis, add 1 milliliter of diluted single-cell suspension to a rehydrated single-cell Western blot chip in the bottom of a 10-centimeter Petri dish. After five to fifteen minutes, examine the chip under brightfield microscopy. Approximately 15% to 20% of the microwells should be occupied by a single cell, and fewer than 2% of the wells should contain two or more cells.

If the chip has been properly loaded, tilt the dish 45 degrees, and wash the chip three times with suspension buffer to remove any uncaptured cells. After the last wash, carefully load the chip into the electrophoresis cell of a single-cell Western instrument gel-side up, and cover the entire single-cell Western blot chip with lysis/running buffer. Initiate the cell lysis and run the instrument according to the appropriate experiment parameters.

At the end of the run, rinse the chip with two 10-minute washes with fresh washing buffer per wash at room temperature. After the second wash, add 80 microliters of the primary antibody solution of interest to the antibody-probing chamber and lower the chip gel-side down so that the antibody solution wicks across the chip.

After two hours at room temperature, wash the chip three times in washing buffer and one time in water on a shaker. Incubate the chip with an appropriate secondary antibody for one hour at room temperature, protected from light. At the end of the incubation, wash the chip three times with washing buffer, and spin the chip on a slide spinner to remove any remaining washing buffer.

To strip the single-cell Western blot chip, place a 50-milliliter tube rack in a 60-degree Celsius water bath with the water just 1 centimeter above the rack. In a fume hood, add 40 milliliters of stripping buffer, and 320 microliters of beta-mercaptoethanol to a canister. Place the chip in a 10-centimeter Petri dish inside the canister and seal the canister with parafilm.

Then, place the canister inside the tube rack in the water bath. After 90 minutes, carefully transfer the chip into a new Petri dish, and briefly wash the chip one time with wash buffer before adding 15 milliliters of fresh washing buffer to the Petri dish for a 15-minute wash on the shaker.

Read Article

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter