Myograph Chamber

A myograph chamber is an experimental system used to measure the force generated by isolated muscle tissue, particularly blood vessels, under controlled laboratory conditions. In a typical setup, a vessel ring or other tissue segment is mounted between fixed and movable supports in an oxygenated physiological solution, while a force transducer records changes in isometric tension. Researchers can adjust resting tension, temperature, and solution composition, then apply drugs or electrical stimulation to assess contraction and relaxation. Myograph studies help characterize vascular reactivity, smooth muscle function, and pharmacological responses, supporting research into hypertension, cardiovascular disease, and potential therapeutic agents.

Myograph Chamber - Related Videos

Research

JoVE Journal - Biology

Assessing Murine Resistance Artery Function Using Pressure Myography

0 Views •

Cited by 18 •

2013

In pressure myography, an intact small segment of a vessel is mounted onto two small cannulas and pressurized to a suitable luminal pressure. Here, we describe the method to measure vasorelaxation response of the mouse 3rd order mesenteric arteries in c57 and sGCα1-/- mice using pressure myography.

Measurement of Endothelium-Dependent Vasorelaxation in the Mouse Thoracic Aorta Using Tensometric Small Volume Chamber Myography

0 Views •

Cited by 1 •

2022

The present protocol describes the concepts and technical application of the tensometric myograph technique using a multi-chamber myograph system in the experimental ex vivo assessment of mouse aortic endothelial function.

Exploring Arterial Smooth Muscle Kv7 Potassium Channel Function using Patch Clamp Electrophysiology and Pressure Myography

0 Views •

Cited by 8 •

2012

Measurements of Kv7 (KCNQ) potassium channel activity in isolated arterial myocytes (using patch clamp electrophysiological techniques) in parallel with measurements of constrictor/dilator responses (using pressure myography) can reveal important information about the roles of Kv7 channels in vascular smooth muscle physiology and pharmacology.

Mesenteric Artery Contraction and Relaxation Studies Using Automated Wire Myography

0 Views •

Cited by 37 •

2011

An automated myography method for force measurements in isolated mesenteric arteries is described. It employs a Mulvany-Halpern Auto Dual Wire Myograph 510A to determine responses to phenylephrine and extracellular calcium. The method allows consistent determination of isometric responses to agonists in small vessels of diameters of 60 - 300 μm, independently.

Assessing Myogenic Response and Vasoactivity In Resistance Mesenteric Arteries Using Pressure Myography

0 Views •

Cited by 24 •

2015

Pressure myography is used to assess vasoactivity of small arteries that develop sustained constriction when pressurized. This manuscript provides a detailed protocol to assess in isolated segments of small mesenteric arteries from rats, vasoactivity and the effect of intraluminal pressure on vascular diameter.

View All Results