-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

IT

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

it_IT

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Biology
Nuove tecniche di imaging con tomografia microcomputerizzata in vivo per valutare la pro...
Nuove tecniche di imaging con tomografia microcomputerizzata in vivo per valutare la pro...
JoVE Journal
Biology
Author Produced
This content is Free Access.
JoVE Journal Biology
Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease

Nuove tecniche di imaging con tomografia microcomputerizzata in vivo per valutare la progressione della steatosi epatica non alcolica

Full Text
1,812 Views
08:41 min
March 24, 2023

DOI: 10.3791/64838-v

Anna Hadjihambi*1,2, Rallia-Iliana Velliou*3, Panagiotis Tsialios4, Aigli-Ioanna Legaki3, Antonios Chatzigeorgiou*3, Maritina G. Rouchota*4

1The Roger Williams Institute of Hepatology London,Foundation for Liver Research, 2Faculty of Life Sciences and Medicine,King's College London, 3Department of Physiology, Medical School,National and Kapodistrian University of Athens, 4BIOEMTECH,Lefkippos Attica Technology Park NCSR "Demokritos"

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study investigates a novel non-invasive micro-computed tomography (micro-CT) imaging technique to monitor the progression of non-alcoholic fatty liver disease (NAFLD) in a diet-induced mouse model. The method focuses on analyzing the hepatic vascular network, a key factor in liver disease dysregulation.

Key Study Components

Research Area

  • Non-alcoholic fatty liver disease (NAFLD)
  • Micro-computed tomography imaging
  • Hepatic vascular network analysis

Background

  • NAFLD is a common liver condition associated with various metabolic disorders.
  • Understanding liver vascular changes is critical for assessing disease progression.
  • Current methods for evaluating liver disease often lack non-invasive approaches.

Methods Used

  • In vivo micro-CT imaging techniques
  • Diet-induced NAFLD mouse model
  • Contrast agents to visualize liver pathology

Main Results

  • Identified changes in hepatic vascular network volume and portal vein diameter.
  • Correlation established between liver fat percentage and vascular characteristics.
  • Demonstrated feasibility of using micro-CT for long-term liver disease assessment.

Conclusions

  • The study validates a non-invasive imaging method for monitoring NAFLD progression.
  • Findings may contribute to the development of new therapeutic strategies.

Frequently Asked Questions

What is NAFLD?
NAFLD stands for non-alcoholic fatty liver disease, a condition characterized by excessive fat accumulation in the liver unrelated to alcohol consumption.
How does micro-CT imaging work?
Micro-CT imaging provides high-resolution images of internal structures, utilizing X-ray technology to create detailed 3D reconstructions of tissues.
Why is the hepatic vascular network important in NAFLD?
The hepatic vascular network plays a crucial role in liver function and its dysregulation contributes to the progression of NAFLD.
What are the benefits of using non-invasive techniques?
Non-invasive techniques reduce stress and harm to animal models, allowing for safer long-term studies of disease progression and treatment effects.
Can this method be applied to human studies?
While this study focuses on a mouse model, similar imaging techniques could potentially be adapted for human studies in the future.
What are the next steps for this research?
Future research will focus on validating these findings in larger cohorts and exploring treatment mechanisms for NAFLD using this imaging approach.

Utilizzando un modello murino di steatosi epatica non alcolica (NAFLD) indotto dalla dieta, descriviamo l'uso di nuove tecniche di imaging di tomografia microcomputerizzata in vivo come metodo non invasivo per valutare le fasi di progressione della NAFLD, concentrandoci prevalentemente sulla rete vascolare epatica a causa del suo significativo coinvolgimento nella disregolazione epatica correlata alla NAFLD.

Riteniamo che questo protocollo sia significativo perché dimostra un metodo non invasivo, semplice e facile per valutare nel tempo gli indicatori chiave per la diagnosi di malattia epatica. Questa metodologia di imaging consente l'analisi nel tempo degli stati epatici, la valutazione del volume ematico relativo, il diametro della vena porta, l'intensità della rete vascolare, tutti parametri importanti della patologia epatica. Comprendere gli adattamenti della rete vascolare epatica durante la progressione della NAFLD e correlarli con marcatori specifici come la steatosi, l'infiammazione e la fibrosi può aiutare a stabilire nuovi schemi terapeutici efficienti.

Questa tecnica aiuta nell'identificazione di tali marcatori e migliora anche il valore dei topi negli studi preclinici incentrati sullo sviluppo di nuove terapie contro la progressione della malattia. Per iniziare, posizionare l'animale anestetizzato nella culla dello scanner CT. Applicare un unguento oftalmico, fissare l'ogiva nasale e impostare i parametri di scansione sullo scanner CT.

View the full transcript and gain access to thousands of scientific videos

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Biologia Numero 193

Related Videos

Valutazione della solidità del grasso umano iniezione in topi nudi con Micro-Tomografia Computerizzata

11:13

Valutazione della solidità del grasso umano iniezione in topi nudi con Micro-Tomografia Computerizzata

Related Videos

11.7K Views

In Vivo quantitativa valutazione della struttura del miocardio, la funzione, la perfusione e sostenibilità Utilizzando cardiaca micro-tomografia computerizzata

08:13

In Vivo quantitativa valutazione della struttura del miocardio, la funzione, la perfusione e sostenibilità Utilizzando cardiaca micro-tomografia computerizzata

Related Videos

20.2K Views

Analisi ottimizzata delle In Vivo e In Vitro Epatica steatosi

08:58

Analisi ottimizzata delle In Vivo e In Vitro Epatica steatosi

Related Videos

17K Views

Un Multimodal Imaging approccio basato su Micro-CT e fluorescenza molecolare tomografia per valutazione longitudinale della fibrosi polmonare indotta da bleomicina in topi

07:38

Un Multimodal Imaging approccio basato su Micro-CT e fluorescenza molecolare tomografia per valutazione longitudinale della fibrosi polmonare indotta da bleomicina in topi

Related Videos

12.2K Views

Applicazione dell'imaging ecografico a ultrasuoni e dell'elastografia a onde di taglio in un modello di ratto di NAFLD / NASH

07:13

Applicazione dell'imaging ecografico a ultrasuoni e dell'elastografia a onde di taglio in un modello di ratto di NAFLD / NASH

Related Videos

4.6K Views

Imaging 3D della matrice extracellulare del fegato in un modello murino di steatoepatite non alcolica

06:46

Imaging 3D della matrice extracellulare del fegato in un modello murino di steatoepatite non alcolica

Related Videos

2.4K Views

Analisi di goccioline lipidiche colorate con fluorescenza con ricostruzione 3D per la valutazione della steatosi epatica

07:12

Analisi di goccioline lipidiche colorate con fluorescenza con ricostruzione 3D per la valutazione della steatosi epatica

Related Videos

8.6K Views

Trapianto ortotopico di fegato di successo nei topi che utilizzano l'angiografia con tomografia microcomputerizzata

09:23

Trapianto ortotopico di fegato di successo nei topi che utilizzano l'angiografia con tomografia microcomputerizzata

Related Videos

3.7K Views

Una tecnica di quantificazione 3D per l'analisi della distribuzione della frazione di grasso epatico utilizzando la risonanza magnetica Dixon

05:37

Una tecnica di quantificazione 3D per l'analisi della distribuzione della frazione di grasso epatico utilizzando la risonanza magnetica Dixon

Related Videos

2.2K Views

Nuovo protocollo di quantificazione per la progressione della calcificazione cardiovascolare utilizzando immagini longitudinali MicroPET/MicroCT

08:02

Nuovo protocollo di quantificazione per la progressione della calcificazione cardiovascolare utilizzando immagini longitudinali MicroPET/MicroCT

Related Videos

1K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code