このコンテンツを表示するには、JoVEへの購読が必要です。 または、無料トライアルをお申し込みください。

方法論記事

Extraction of Viral RNA from Surface-Bound Virions Using a Silica Spin Column

143 回視聴

2026年7月31日

この記事について

要約

Source: Klaus, J. P. et al. Highly Sensitive Assay for Measurement of Arenavirus-cell Attachment. J. Vis. Exp. (2016)

This video demonstrates the extraction of viral RNA from surface-bound virions on epithelial cells using silica spin columns. The method includes chemical lysis, RNA stabilization, and membrane-based purification for downstream quantification of virus-cell attachment.

プロトコル

Viral RNA Extraction

  1. Purify viral RNA from Junín virus (JUNV) C#1 particles attached to the monolayers using a commercial kit (e.g., the RNeasy Mini kit) according to the manufacturer's protocol. Specifically, follow the "purification of total RNA from animal cells using spin technology protocol" on pages 23-28 in the RNeasy Mini Handbook (4th Edition, April 2006) with the modifications listed below.
    1. Lyse the cells by adding 350 µl of lysis buffer RLT directly to each well. Mix the buffer several times to ensure cell lysis. Note that cells easily lyse in this buffer, and complete lysis can be verified by viewing wells under an inverted microscope.
    2. Transfer the resulting cell lysate to the kit column and follow the rest of the protocol as described. At this point, the virus has been neutralized by the lysis buffer, so the remaining steps of the protocol can be done outside of the class II biosafety cabinet, provided the kit tubes were not contaminated with infectious virus.
    3. Include the optional step from the manufacturer's protocol, which is an additional centrifugation of the spin column to eliminate any possible carryover of Buffer RPE.
    4. In the final step, the manufacturer's protocol, elute the purified RNA from the spin column using 30 µl of nuclease-free ddH2O. Store RNA at -80 °C at this point or use directly in the quantitative reverse transcription polymerase chain reaction (qRT-PCR) assay. To prevent degradation of purified viral RNA samples by nucleases, use nuclease-free reagents and equipment, and keep thawed RNA samples on ice.
      NOTE: Buffers RLT and RW1 contain guanidine salt and should not be mixed with bleach. Buffer RW1 contains ethanol.

アクセスが制限されています。このコンテンツを表示するにはログインするか、トライアルを開始してください。

材料

この記事で使用された材料の一覧
名前会社カタログ番号コメント
Vero E6 cellsAmerican Type Culture CollectionCRL-1586 
Costar 48-well plateCorning3548 
RNeasy mini kitQiagen74106Do not mix buffers RLT or RW1 with bleach
QIAshredder homogenizerQiagen79654 
RNase Inhibitor (5000U/100 µl)Life TechnologiesN808-0119 

タグ