-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

JA

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

ja

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Neuroscience
新生児における信頼性の高い視覚イベント関連電位を得る方法
新生児における信頼性の高い視覚イベント関連電位を得る方法
JoVE Journal
Neuroscience
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Neuroscience
How to Obtain Reliable Visual Event-related Potentials in Newborns

新生児における信頼性の高い視覚イベント関連電位を得る方法

Full Text
6,760 Views
07:39 min
October 24, 2019

DOI: 10.3791/60164-v

Lourdes Cubero-Rego1, Josefina Ricardo-Garcell1, Thalía Harmony1, María Corsi-Cabrera1,2

1Research Unit in Neurodevelopment, Institute of Neurobiology,National Autonomous University of Mexico, 2Sleep Laboratory, Faculty of Psychology,National Autonomous University of Mexico

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This article presents a protocol for obtaining high-quality visual evoked potentials (VEPs) from newborns. It emphasizes minimizing variability and ensuring reliable recordings to facilitate early detection of central nervous system abnormalities. The study highlights the importance of recording during active sleep and provides detailed guidelines for electrode placement and recording procedures.

Key Study Components

Area of Science

  • Neuroscience
  • Neonatal Development
  • Electrophysiology

Background

  • Visual evoked potentials are essential for assessing brain function in newborns.
  • Reducing variability during recordings can improve diagnostic accuracy.
  • Active sleep is identified as the optimal state for VEP recording.

Purpose of Study

  • To establish a reliable method for recording VEPs in newborns.
  • To guide practitioners in minimizing factors that could affect VEP outcomes.
  • To aid in the early identification of neurological issues in at-risk infants.

Methods Used

  • The study employs a clinical setting for VEP recording during active sleep.
  • A newborn model is used, with detailed protocols for preparation and electrode placement.
  • Specific timelines for preparation and recording are provided, including hygiene practices.
  • Electrodes are placed according to the International 10-20 System, with monitoring of impedance levels.

Main Results

  • Clear and reproducible VEP waveforms can be obtained, particularly during defined active sleep stages.
  • Identification of VEP components (e.g., PII, NII, NIII) enables evaluation of brain responsiveness.
  • Variability is reduced through careful monitoring and stimulation protocols, improving diagnostic reliability.

Conclusions

  • This study demonstrates a reliable methodological approach for VEP recordings in newborns.
  • The protocols established facilitate early detection of developmental abnormalities.
  • Findings support better understanding of neural development and potential interventions for at-risk populations.

Frequently Asked Questions

What are the advantages of the described VEP recording method?
This method allows for non-invasive monitoring of brain function in newborns, providing critical information for early intervention.
How is the newborn prepared for VEP recording?
Preparation involves washing the baby's hair, allowing feeding before recording, and ensuring the scalp is clean before electrode placement.
What outcomes can be measured from VEP recordings?
The recordings allow for assessment of latency and amplitude of VEP components, which indicate brain responsiveness and potential developmental issues.
How can this method be adapted for different settings?
The method can be tailored by adjusting hygiene protocols and electrode placements based on local hospital practices while maintaining core principles.
What are key limitations to consider?
Variability may still occur due to external factors or infant movement, and recordings must be carefully monitored for accurate results.

新生児の高品質で信頼性の高い視覚誘発電位(VEP)を得るためのいくつかの重要な点を、変動性と誤解を招く予後のリスクを最小限に抑えること。

中枢神経系における異常発生の早期発見には、高品質の視覚事象関連の可能性を得ることが重要であり、リスクの高い新生児の早期介入の実施を成功させるためには重要である。VEPは客観的で非侵襲的で、構造的および機能的な脳損傷に敏感である。ポリソムノグラフィーで識別されたアクティブスリープ中の記録は変動性を減少させ、信頼性の高いVEPを得ることができます。

研究の前日、赤ちゃんの頭が中性の石鹸で洗われていることを確認して、髪が清潔で乾燥していることを確認してください。研究を開始する30分前に、赤ちゃんが簡単かつ自発的に眠るように、赤ちゃんをげっぷし、シートに赤ちゃんを包む前に、親が新生児に餌を与え始めることができるようにします。新生児を取り扱う前に、手を慎重に洗い、衛生マスクを着用してください。

新生児が眠りに落ちる前に、残りの汚れと表面的なグリースを取り除き、鼻とイニオンの間、および両方の耳前ピット間の距離を測定するために、アルコールで新生児の頭皮を静かに拭きます。国際10-20系電極配置に従って頭蓋電極の適切な配置を確実にするために10%と20%を計算し、EEGおよびVEP電極の正しい取り付けのための管状弾性メッシュで新生児の頭部全体を覆い、顔を完全に自由に露出させます。メッシュ上の表面電極の位置をマークし、綿棒を使用して、各電極が配置される部位で新生児の髪を完全に分離し、神経生理学的研究のために研磨ゲルで皮膚を軽くこすります。

電極配置では、赤ちゃんの胸部に弾性バンドセンサーを置いて胸部の呼吸膨張を記録し、リードF3、F4、C3、C4、O1、およびO2でメッシュを介してEEG用の個々の表面ディスク電極を見つけます。眼の動きを記録するには、左目の外付けカンサスの上に1センチメートル上のメッシュを通して1つの電極を配置し、右目の外形カンサスの下に1センチメートルの別の電極を置きます。医療用粘着テープで電極を皮膚に固定し、互いに参照している顎の両側に表面筋電図記録用の電極を取り付けます。右のマストイドにグランド電極を置き、Oz対Czリード線でVEP装置の1チャンネルを設定し、VEP登録の解析時間を600ミリ秒に設定し、インピーダンス値が5キロオーム以下になるまでVEP記録を開始するのを待ちます。

新生児が病院のベビーベッドで寝ていると、アクティブな睡眠が特定されるまで、EEG記録を60〜90分間延長する。表に要約された基準に従って、新生児睡眠の特徴を注意深く観察しながら、VEPが記録されるアクティブな睡眠段階を特定しながら、EEG記録を開始します。新生児が明確に定義されたアクティブな睡眠をもたらすとき、単眼光刺激を適用するために各目の上に2センチメートルのLEDマトリックスでハンドヘルドゴーグルを配置する前に、EEG記録の1分を可能にする。

アクティブな睡眠中のVEP登録中に乳児の目が閉じているかどうかを観察し、20〜40の発光刺激を提示し始める。記録中に、記録された平均の再現性を確認し、PII成分を負のNII波の前に120〜300ミリ秒の間の最大正のピークとして識別し、その後に200〜400ミリ秒の間に最大NIII否定性を与えます。新生児が過度に動いたり、目覚めたり、アクティブな睡眠とは異なる別の睡眠段階に変化したりした場合は、平均化を中止します。

再現可能なVEPを使用した2つの平均が達成された後、または認識可能なVEPなしで6つの平均が発生した後に登録を終了します。解析の最後に、2つの平均カーブ間の類似した外観と測定値によってVEPsの再現性を評価し、デバイスカーソルを使用してNII、PII、およびNIII波の絶対遅延を測定します。絶対PII-NII、NII-NIII、PII-NIIIの絶対遅延の差を含むピーク間の遅延をミリ秒単位で計算し、NII-PIIおよびPII-NIII成分のマイクロボルトのピークからピークまでの振幅を測定し、正常な新生児の正常または予測された推定値で得られた振幅値の遅延を比較します。

健康な、完全な期間の新生児では、PII成分と互換性のある約200ミリ秒の明確な陽性が観察され得る。NIIは、先行する負の小さな電位に対応し、約130ミリ秒で明らかです。NIII コンポーネントは、PII に続いて約 300 ミリ秒の否定性を示します。

ここでは、アクティブな睡眠、静かな睡眠、およびトレースオルタナントの典型的な側面を持つ睡眠EEGの3つのエポックが示されている。フルターム新生児では、典型的なVEP波形は、この年齢で正常である未熟な新生児で観察された未熟な応答である明確なPIIを示し、このトレースは、前の平均の形状を正確に再現しない波を有する非複製波形である36週齢の早産児からの、以前の平均の形状を正確に再現しない非複製波形を観察することができ、信頼性の高い遅延または遅延の測定を不可能にする。この手順を試みるときは、アクティブな睡眠を注意深く観察する必要があります。

状態変化時のVEP記録は避け、再現性は少なくとも2つの平均波形で達成されなければならない。適切な感覚刺激を使用して、体性感覚および聴覚中長期遅延誘発応答を得て、他の感覚経路における病理学的状態を評価するための敏感で非侵襲的な手段を提供することができる。

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

神経科学 問題 152 脳波 視覚誘発電位 睡眠 新生児 早経 アクティブ睡眠 多視道法

Related Videos

電気生理学的測定とヒト幼児における痛覚の分析

09:18

電気生理学的測定とヒト幼児における痛覚の分析

Related Videos

17.6K Views

早産児脳波:マルチモーダル神経生理学的プロトコル

19:32

早産児脳波:マルチモーダル神経生理学的プロトコル

Related Videos

29K Views

脳波に結合されたフラットチッププローブを使用した新生児の痛み誘発脳活動の測定

02:50

脳波に結合されたフラットチッププローブを使用した新生児の痛み誘発脳活動の測定

Related Videos

644 Views

P50 乳児の感覚ゲーティング

12:55

P50 乳児の感覚ゲーティング

Related Videos

9.6K Views

子供高密度脳波記録の皮質ソース解析

09:32

子供高密度脳波記録の皮質ソース解析

Related Videos

21.9K Views

幼児聴覚処理とイベント関連の脳の振動

06:34

幼児聴覚処理とイベント関連の脳の振動

Related Videos

16.9K Views

自由に振る舞うヒト乳児における社会的相互作用の間に意思のマルチモーダル神経デコーディングするための新規の実験と解析手法

11:14

自由に振る舞うヒト乳児における社会的相互作用の間に意思のマルチモーダル神経デコーディングするための新規の実験と解析手法

Related Videos

11.4K Views

ターゲット応答の作業中に事象関連電位片側脳性麻痺児の上肢利用の認知プロセスを研究するために

08:26

ターゲット応答の作業中に事象関連電位片側脳性麻痺児の上肢利用の認知プロセスを研究するために

Related Videos

12.6K Views

新生児脳波に結合されたフラット先端プローブを用いた有害誘発脳活動の電気生理学的測定

06:29

新生児脳波に結合されたフラット先端プローブを用いた有害誘発脳活動の電気生理学的測定

Related Videos

7.1K Views

刺激特異的皮質視覚誘発潜在的形態パターン

09:42

刺激特異的皮質視覚誘発潜在的形態パターン

Related Videos

6.4K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code