-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

JA

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

ja

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Bioengineering
ミニブタにおける硬膜下軟性皮質電図(ECoG)アレイ移植と長期皮質記録
ミニブタにおける硬膜下軟性皮質電図(ECoG)アレイ移植と長期皮質記録
JoVE Journal
Bioengineering
This content is Free Access.
JoVE Journal Bioengineering
Subdural Soft Electrocorticography (ECoG) Array Implantation and Long-Term Cortical Recording in Minipigs

ミニブタにおける硬膜下軟性皮質電図(ECoG)アレイ移植と長期皮質記録

Full Text
4,018 Views
08:30 min
March 31, 2023

DOI: 10.3791/64997-v

Florian Fallegger*1, Alix Trouillet*1, Stéphanie P. Lacour1

1Laboratory for Soft Bioelectronic Interfaces, Neuro-X Institute,Ecole Polytechnique Fédérale de Lausanne

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study presents a method for assessing the long-term performance and safety of soft subdural electrode arrays in a minipig model. It details the surgical approach, postoperative imaging, and the electrophysiological and electrochemical evaluation of the implant.

Key Study Components

Area of Science

  • Neuroscience
  • Biomedical Engineering
  • Electrophysiology

Background

  • The need for chronic cortical devices in neuroscience research.
  • Importance of biocompatibility and signal quality in implants.
  • Challenges in long-term monitoring of neural devices.
  • Use of large animal models for device testing.

Purpose of Study

  • To establish a reproducible method for long-term safety and efficacy assessment of cortical devices.
  • To facilitate neural monitoring and imaging over time.
  • To contribute to the development of neuroprosthetics for sensory and motor functions.

Methods Used

  • Surgical implantation of soft subdural electrode arrays in minipigs.
  • Postoperative magnetic resonance imaging (MRI) for implant assessment.
  • Electrophysiological recordings of auditory cortex activity.
  • Electrochemical characterization of the implants over time.

Main Results

  • Successful implantation and monitoring of brain signals over time.
  • In vivo imaging confirmed proper implant placement and brain integrity.
  • Electrochemical properties of the devices were stable over six months.
  • Clear identification of neuronal layers and inflammatory markers via imaging.

Conclusions

  • This method provides a robust framework for evaluating chronic cortical devices.
  • It enhances understanding of large-scale cortical network activity.
  • The approach can be adapted for other large animal models.

Frequently Asked Questions

What is the significance of using a minipig model?
Minipigs provide a suitable large animal model for studying chronic cortical devices due to their anatomical and physiological similarities to humans.
How does the surgical method ensure device stability?
The surgical method includes securing the implant with titanium bridges and screws, ensuring it remains stable during long-term monitoring.
What imaging techniques were used in this study?
Postoperative MRI and intraoperative X-ray imaging were utilized to assess implant positioning and brain integrity.
What were the main findings regarding electrochemical properties?
The electrochemical characterization showed stable impedance and phase measurements over the six-month implantation period.
Can this method be applied to other types of implants?
Yes, the methodology can be adapted for various types of chronic cortical devices and other large animal models.
What are the implications for neuroprosthetic development?
This study provides insights into the long-term performance of implants, aiding in the design of more effective neuroprosthetics for sensory and motor functions.

ここでは、ミニブタモデルにおける軟硬膜下電極アレイの長期的な性能と安全性を評価する方法を提示し、手術方法とツール、術後の磁気共鳴画像法、聴覚皮質の電気生理学、インプラントの電気化学的特性、および死後の免疫化学について説明します。

このモデルは、生体適合性、分解能、シグナル品質の観点から、慢性皮質デバイスの安全性と有効性を検証するための標準となる可能性があります。私たちの手順は、デバイスの安全性と有効性の長期的なフォローアップを実行するための再現性と拡張性のある方法を説明しています。これには、経時的な神経モニタリング、in vivoおよびex vivoイメージングが含まれます。

私たちの方法は、感覚的および運動皮質神経プロテーゼの開発に役立ちます。これは、大規模な皮質ネットワークの活動を理解するためのツールです。この方法は、さまざまな皮質領域にわたる機能的接続を調査するために、基礎神経科学に使用できます。

他の大型動物モデルにも適用できます。外科的アプローチにはある程度の練習が必要ですが、最初に死体や急性実験で習得することができます。そうすれば、測定はかなり簡単になります。

まず、麻酔をかけた動物の皮膚をメスナイフで正中線に沿って切開します。ラスパトリーを使用して筋肉と骨膜を骨から分離し、最適なアクセスのためにスプレッダーを配置します。開頭術を行うには、X線で測定された頭蓋骨の厚さを考慮して、丸い切断ビットを備えた骨ドリルを使用して輪郭をドリルで開けます。

骨の過熱を避けるために、掘削場所を生理食塩水で灌漑します。硬膜に達するまで、輪郭を均一に慎重にドリルで開けます。最初のブレークスルーでは、アウトラインがほぼ突き抜けるほど薄くなるまで穴あけを終了します。

次に、平らなスパチュラを使用して、開頭術の縁をテコにして骨皮弁を1つに分解します。硬膜切開術を行うには、6オー縫合キットの針を使用して、開頭術の前端または後端、内側と外側の中間にある硬膜を慎重に突き刺して持ち上げ、スタブナイフで切開の始まりを作成します。次に、硬膜下腔に挿入された小さな平らなヘラを使用して、皮質を保護するための切断ベースとして機能します。

両方のツールを同時に進めることにより、硬膜に前後スリットを作成します。スリットがインプラントの幅よりわずかに大きいことを確認してください。インプラントを硬膜スリットの上に置き、小さな鉗子で、各端を順番にスライドさせて硬膜下に挿入します。

デバイスの台座の端を慎重に保持し、挿入を妨げる張力を発生させないようにインプラントを前進させます。コネクタの端がスリットの上に来たら、挿入を停止します。インプラントを所定の位置に固定するには、開頭術の端または固定翼のケーブルの上にチタン製のブリッジを配置し、適切なドライバーを使用して1本または2本のチタン製ネジで固定します。

次に、インプラントケーブルの周囲に硬膜を慎重に縫合します。3オーの吸収性縫合糸と小さなニードルホルダーを使用して、縫合糸ワイヤーで薄い膜を引き裂くことなく、2つの硬膜の縁をできるだけ一緒にします。骨フラップの留置を行うには、チタン製のネジを使用して、各骨フラップの前部と後部にチタン製のブリッジを固定します。

チタンブリッジの端を頭蓋骨にねじ込みます。次に、フットプレートの向きを計画して、すべての脚が頭蓋骨にねじ込まれるようにします。次に、フットプレートのチタンネジをしっかりと固定されるまでねじ込んで、フットプレートを固定します。

次に、台座をフットプレートにねじ込みます。縫合糸を3ミリメートル離して、4オーの非吸収性縫合糸ワイヤーで皮下縫合糸を作成します。台座から離れ、切開の両側で台座に向かって移動します。

次に、6オーの非吸収性縫合ワイヤーを使用して皮膚を縫合することにより、真皮層を閉じます。縫合糸を5ミリメートル離して。台座から離れ、切開の両側で台座に向かって移動します。

空隙を避けるために、2つの皮膚フラップの間と台座の端の近くで良好な組織配置を実現するように注意してください。動物を抱っこしたり、おやつを与えて気をそらしたりして、ワイヤレスヘッドステージを動物に接続した後、覚醒している脳信号を記録します。信号を記録するときは、必ず ampアンテナと外部スピーカーを豚のケージの近くに置きます。

800ヘルツのトーンバースト刺激に応答する音刺激および聴覚誘発電位を伴わないベースライン活動を電極アレイ上にマッピングすることができる。単一の電極チャネルにおける聴覚誘発電位は、オンの「応答」を示す矢印で経時的に示され、ベースライン活性は比較として示されています。In vivoイメージングは、脳の状態とインプラントの位置を評価するために、術中および術後に実施されました。

術中平面X線検査でインプラント埋入が確認され、X線不透過性マーカーの埋入で観察された折り畳みはありませんでした。術後のMRIで観察できるように、脳の表面は無傷です。全体として、このインプラントとペデスタルシステムにより、インプラント期間中の全脳イメージングが可能になり、インプラントの周りの解剖学的構造や液体や血液の存在を確認できます。

さらに、この研究では臨床用電極が比較対象として使用されていますが、加熱と安全上の懸念からMRIで画像化できず、CTスキャンが必要です。提示されたパイプラインは、全脳抽出と全半球を画像化するための切片化を可能にします。組織切片全体の画像化では、明瞭なニューロン層が見られました。

細胞は20倍の共焦点イメージングで明確に定義され、炎症マーカーの精密な調査を可能にします。デバイスの電気化学的特性評価を使用して、インピーダンス弾性率と位相をin vitroで抽出し、移植の6か月間に1キロヘルツで経時的に追跡しました。手術中に副鼻腔が開かないように、動物の年齢と大きさを慎重に選択することが重要です。

これは慢性的な実験を損なうことになります。硬膜にアクセスしたり、インプラントを挿入したりするときに出血を避けることが重要です。これにより、さらなる合併症や炎症反応を回避できます。

このモデルが確立されると、ミニブタで自由に振る舞う電気生理学を実行し、皮質の関心領域からの活動を記録するために使用できます。この方法は、ヒトに翻訳される新しい神経補綴物を開発する際の臨床試験の提出のためのバイオセーフティデータの収集に適用できます。

Explore More Videos

Bioengineering Issue 193 神経学的障害 疾患 皮質電図(ECoG)アレイ 薬剤耐性てんかん てんかん領域 切除 ブレイン コンピュータ インターフェース 皮質上電極 運動意図 ロボット手足 麻痺患者 スティッフ電極グリッド 高解像度脳記録 長期バイオインテグレーション コンフォーマブル電極アレイ 前臨床試験 インプラント技術 機能性 安全性プロファイル ヒト患者への翻訳 ブタモデル 医療デバイス 臓器サイズ 動物の取り扱いの容易さ 手術の制限

Related Videos

単一ユニット活動とElectrocorticographic信号を記録するための慢性神経電極の外科的移植

08:26

単一ユニット活動とElectrocorticographic信号を記録するための慢性神経電極の外科的移植

Related Videos

48.4K Views

皮質電気記録のためのマウス皮質への電極の埋め込み

03:59

皮質電気記録のためのマウス皮質への電極の埋め込み

Related Videos

1.2K Views

ミニブタの皮質電気生理学記録のための軟皮質電気皮質検査アレイの硬膜下移植

04:00

ミニブタの皮質電気生理学記録のための軟皮質電気皮質検査アレイの硬膜下移植

Related Videos

640 Views

麻酔ラットにおける脳波および局所電位記録の同時実施

04:17

麻酔ラットにおける脳波および局所電位記録の同時実施

Related Videos

791 Views

鍼治療によりラットとマウスにおけるてんかんElectrocorticograms(ECoGs)の操作とスリープ

09:06

鍼治療によりラットとマウスにおけるてんかんElectrocorticograms(ECoGs)の操作とスリープ

Related Videos

10.2K Views

慢性的な経頭蓋電気刺激およびラットの皮質内の記録

10:51

慢性的な経頭蓋電気刺激およびラットの皮質内の記録

Related Videos

9.3K Views

そのまま子豚脳内麻酔神経毒性の研究のための微小電極アレイ技術の適応

08:23

そのまま子豚脳内麻酔神経毒性の研究のための微小電極アレイ技術の適応

Related Videos

9.9K Views

子豚を自由に移動するから非侵襲的脳波

04:05

子豚を自由に移動するから非侵襲的脳波

Related Videos

7.8K Views

一般的なセットの全皮質のシェットランドシープドッグ配列の慢性注入

04:43

一般的なセットの全皮質のシェットランドシープドッグ配列の慢性注入

Related Videos

10.4K Views

ブタの麻酔中に皮質記録を繰り返すための慢性頭蓋窓法

07:19

ブタの麻酔中に皮質記録を繰り返すための慢性頭蓋窓法

Related Videos

582 Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code