-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

JA

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

ja

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Neuroscience
DREAMインプラント:頭部固定マウスと自由行動マウスの慢性電気生理学のための軽量でモジュール式で費用...
DREAMインプラント:頭部固定マウスと自由行動マウスの慢性電気生理学のための軽量でモジュール式で費用...
JoVE Journal
Neuroscience
This content is Free Access.
JoVE Journal Neuroscience
The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice

DREAMインプラント:頭部固定マウスと自由行動マウスの慢性電気生理学のための軽量でモジュール式で費用対効果の高いインプラントシステム

Full Text
1,967 Views
08:42 min
July 26, 2024

DOI: 10.3791/66867-v

Tim Schröder*1,2, Robert Taylor*3, Muad Abd El Hay3, Abdellatif Nemri2, Arthur França1, Francesco Battaglia1, Paul Tiesinga1, Marieke L. Schölvinck*3, Martha N. Havenith*1,2,3

1Donders Institute for Brain, Cognition and Behaviour,Radboud University, 23D Neuro B.V., 3Zero-Noise Lab,Ernst-Strüngmann Institute for Neuroscience

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study introduces a novel lightweight and cost-effective probe implant system designed for chronic electrophysiology in rodents. It enhances experimental versatility and probe recovery while ensuring compatibility with behavioral tasks, thereby facilitating the simultaneous recording of neuronal activity during meaningful animal behaviors.

Key Study Components

Area of Science

  • Chronic electrophysiology
  • Behavioral neuroscience
  • Neurotechnology

Background

  • Studying decision-making and rule learning in rodents.
  • Investigating interactions between the anterior cingulate cortex and sensory regions.
  • Emphasizing the importance of naturalistic behaviors in understanding neural computation.
  • Addressing challenges in obtaining high-quality neuronal recordings during complex behaviors.

Purpose of Study

  • To develop an implant system that can record neuronal activity comfortably during behavioral tasks.
  • To enhance accessibility of electrophysiology for labs with limited resources.
  • To compare neuronal and behavioral measurements in mice and macaques in a naturalistic environment.

Methods Used

  • The study utilized a lightweight and modular microdrive implant system.
  • The primary biological model included mice and macaques performing virtual reality foraging tasks.
  • Key steps include careful surgical preparation for probe implantation and ensuring probe stability during experiments.
  • Recorded neuronal activity was aimed at understanding behavioral states in both species.

Main Results

  • Found similarities in computational dynamics and behavioral states between mice and monkeys.
  • Demonstrated effective recording of neuronal activity aligned with natural behaviors.
  • Introduced a versatile implant design that addresses technical challenges in chronic electrophysiology.

Conclusions

  • The study showcases a new implant system that improves the feasibility of chronic electrophysiology in behavioral studies.
  • This innovative approach enables researchers to uncover insights into neural mechanisms and decision-making processes.
  • It holds implications for advancing electrophysiology in various research contexts, particularly for labs with fewer resources.

Frequently Asked Questions

What are the advantages of the new probe implant system?
The implant system is lightweight, cost-effective, and modular, allowing for flexible electrode placement and easier probe recovery, enhancing experimental applicability.
How is the biological model implemented in this study?
The biological model consists of mice and macaques engaged in virtual reality foraging tasks, facilitating the study of naturalistic decision-making and behavioral responses.
What type of data is obtained using this implant system?
The system provides high-quality recordings of neuronal activity, enabling researchers to analyze excitability changes and behavioral dynamics during tasks.
How can this method be applied in other research contexts?
The implant system can be adapted for various species and tasks, making it suitable for studying different aspects of neural computation in behavior.
What are some key limitations of this implant system?
While the implant system is designed for ease of use, challenges may still arise in ensuring optimal recording quality during particularly complex behaviors.
How does this study impact the field of electrophysiology?
By making electrophysiological methods more accessible, it allows a wider range of laboratories to conduct innovative experiments and contribute to the field.
What key findings were reported comparing mice and monkeys?
The study found that mice and monkeys exhibit similar computational dynamics and behavioral states while performing the same tasks in naturalistic settings.

ここでは、使いやすさ、プローブの回収率、実験の汎用性、および行動との適合性が最適化された、げっ歯類の慢性電気生理学用の軽量で費用対効果の高いプローブインプラントシステムを紹介します。

私たちの研究では、マウスとマカクザルの仮想現実課題と慢性電気生理学を使用して、自然主義的な意思決定とルール学習を研究しています。私たちは、前帯状皮質と視覚野などの感覚領域との間の相互作用に焦点を当てています。そして、このアプローチは、目標指向行動における種特異的または一般化可能な計算戦略を理解することを目的としています。

ニューラルコンピュテーションを真に理解したいのであれば、動物が彼らにとって意味のある自然な行動をとっている間に理解しなければならないという認識が、ある分野として認識され始めていると思います。したがって、ニューロンの活動も同時に記録したい場合、必要なのは、頑丈で動物が快適に着用できるインプラントです。技術的には、最大の課題は、複雑な行動に動物が関与しながら、高収率のニューロン記録を得ることだと思います。

そして、より一般的には、資金や技術リソースが少ない研究室でも電気生理学をより身近なものにすることが非常に重要であり、これにより、どの研究室で働いていても、優れたアイデアを優れた実験に変えるための競争の場を平準化できると考えています。私たちの研究室では、マウスとサルがまったく同じ自然主義的な仮想環境の採餌タスクを行っている場合のニューロンと行動の測定を直接比較しています。そうすることで、実際には多くの計算力学と彼らが経験する行動状態が直接同じであることがわかりました。

DREAMインプラントは、この分野にすでに存在する利点の組み合わせです。軽量でコンパクトでありながら、モジュール式で、電極の配置に柔軟性があり、回復可能なマイクロドライブを備えているため、実験コストが削減されます。まず、0.05インチのはんだテールソケットをシリコンプローブのアース線にはんだ付けします。

マイクロドライブ本体のネジを回して、マイクロドライブシャトルが完全に上向きに引っ込められるようにします。マイクロドライブをマイクロドライブホルダーに水平に置きます。マイクロドライブホルダーに小さな粘着パテを置きます。

次に、シャトルにシリコンプラスターを少し垂らします。フレックスケーブル付きのプローブをマイクロドライブのシャトルに置きます。次に、フレックスケーブルをマイクロドライブの上部に向かってゆっくりと引っ張り、ケーブルの下端がマイクロドライブシャトルの下端に接します。

プローブのヘッドステージコネクタをホルダー上部の接着剤パテに配置します。27ゲージの針またはマイクロブラシを使用して、フレックスケーブルを避けて、電極本体とシャトルの間にシアノアクリレート接着剤を少量塗布します。シリコン石膏を使用して、アンプをクラウンリングに取り付けます。

次に、フレックスケーブルを取り付けます amplifier接続とケーブルをシリコンプラスターの薄い層で覆います。銅メッシュの切り欠きをエポキシ樹脂の小滴でファラデーケージに固定します。まず、すべての滅菌手術器具を滅菌作業プラットフォームに置きます。

麻酔をかけたマウスの剃毛部をヨウ素系消毒剤とアルコールで綿棒で複数回消毒します。マウスをイヤーバーとノーズホルダーを使用して定位フレームに置きます。足をつまんで麻酔の深さを確認します。

小さな手術用ハサミを使用して、頭蓋骨の上の皮膚にアーモンド型の開口部を切り取り、ラムダ縫合糸の後部から目の間まで到達します。皮下膜と骨膜を切除するために切断を続けます。次に、メスの刃で頭蓋骨を引っ掻いて、軟膜組織を取り除きます。

メスの先を逆さまにして、頭蓋骨の表面をざらつかせながら、十字に切るように丁寧に引っ掻きます。メスの刃と滅菌綿棒を交互に使用して、ラムダ縫合糸の側面に取り付けられた首の筋肉を優しく引っ掻いて押しのけ、筋肉が小脳の上の頭蓋骨の端に押し戻されるまで押し戻します。1ミリリットルの注射器を使用して、皮膚と頭蓋骨の縁の間にシアノアクリレート接着剤を少量滴下します。

頭蓋骨全体にデンタルセメントプライマーを塗布して接着力を高め、紫外線で硬化させます。ブレグマまたはラムダに対するプローブの埋め込みの目標位置を見つけ、その周囲の開頭術の輪郭を外科マーカーで概説します。ヘッドプレートをデンタルセメントを使用して頭蓋骨に固定します。

デンタルドリルを使用して、ヘッダーピンの幅に小さなバリ穴を脳の領域に開けます。滅菌生理食塩水をシリンジを使用して開頭術に滴下し、脱落しないワイプで取り除きます。各開頭術にアースピンをそっと挿入し、ヘッダーピンの周りにセメントを塗布します。

次に、より大きな開頭術の輪郭を、安定した動きで端を動かしてドリルで開けます。骨の穴あけ部分の抵抗をテストするには、細い鉗子でそっと押します。シリコンプローブ付きのマイクロドライブをマイクロドライブホルダーに入れます。

ステレオタックスアームを傾けて、目的のターゲット脳領域に到達します。アンプが取り付けられたクラウンリングを、マイクロドライブホルダーの背面にある3本の垂直ピンに取り付けます。マイクロドライブを開頭術から約0.5ミリメートル以内に下げてから、鉗子を使用してアースまたはリファレンスヘッダーピンを接続します。

定位アームをマイクロドライブで開頭術の上に置きます。プローブシャンクがターゲット領域の硬膜に接触するまで、マイクロドライブを下げます。マイクロドライブのベースを所定の位置にセメントで固定します。

ベースと頭蓋骨の間のスペースを歯科用セメントで覆います。次に、シリコンプローブを脳に下ろします。プローブのシャンクが脳に触れたら、プローブを約250マイクロメートルすばやく下げます。

プローブが皮質の表面を突き破ったら、ゆっくりとしたペースでプローブを下げます。1ミリリットルのシリンジを使用して、シリコンエラストマーを少量開頭術に分注します。シリコーンエラストマーをボーンワックスと鉱物油の等量混合物で覆います。

歯科用セメントが固まったら、アレンキーでマイクロドライブホルダーを緩めます。マイクロドライブが自立し、プローブアンプまたはコネクタがフレックスケーブルを伸ばさずにインプラントホルダーに固定されたままになるように、ホルダーを約1センチメートルゆっくりと引っ込めます。既製のクラウンとファラデーメッシュをヘッドプレートの周りに配置して、開口部のケージを伸ばし、マイクロドライブとフレックスケーブルを水平にスロットします。

次に、歯科用セメントでヘッドプレートに固定します。プローブコネクタまたはヘッドステージ付きのファラデークラウンリングをクラウンの上に置き、プローブアンプまたはコネクタの一体型ホルダーをファラデークラウンのインデントXでマークされた領域に合わせます。各スポークリングジャンクションに歯科用セメントを滴下して、リングをファラデーケージに固定します。

固定したら、マイクロドライブホルダーで定位アームを完全に引っ込めます。プローブを接続します amplifierまたはコネクタを記録ハードウェアに接続し、ニューロン信号の記録を開始します。プローブがまだ目標位置に達していない場合は、マイクロドライブのネジをゆっくりと反時計回りに回して、ニューロン信号を監視しながらプローブを下げます。

プローブ全体に神経局所電位が見えたら、テスト記録を終了し、ヘッドステージコネクタを外します。ファラデーケージを自己接着性の獣医用ラップで覆います。

Explore More Videos

今月のJoVEの209号は

Related Videos

ポリイミドベースのマイクロ電極を用いて自由に動くマウスの高密度脳波録音

06:59

ポリイミドベースのマイクロ電極を用いて自由に動くマウスの高密度脳波録音

Related Videos

38.3K Views

マウスの電気生理学的記録のための設計と超軽量重量の作製、調整可能なマルチ電極プローブ

15:43

マウスの電気生理学的記録のための設計と超軽量重量の作製、調整可能なマルチ電極プローブ

Related Videos

18.3K Views

エポックワイヤレス送信機システムを用いたヒト疾患の小型げっ歯類モデルにおいて長期連続EEGモニタリング

08:43

エポックワイヤレス送信機システムを用いたヒト疾患の小型げっ歯類モデルにおいて長期連続EEGモニタリング

Related Videos

26.4K Views

低コストかつオープンソースのリソースの使用げっ歯類モデルにおける高密度脳波取得

12:39

低コストかつオープンソースのリソースの使用げっ歯類モデルにおける高密度脳波取得

Related Videos

16.8K Views

幼若マウスにおける慢性四尾行記録のための軽量駆動インプラント

06:34

幼若マウスにおける慢性四尾行記録のための軽量駆動インプラント

Related Videos

3.7K Views

自由に動くマウスにおけるマルチチャンネル細胞外記録

08:59

自由に動くマウスにおけるマルチチャンネル細胞外記録

Related Videos

3.9K Views

自由に動くマウスにおける慢性マルチサイト脳波記録のための費用対効果が高く低侵襲なプロトコル

07:47

自由に動くマウスにおける慢性マルチサイト脳波記録のための費用対効果が高く低侵襲なプロトコル

Related Videos

585 Views

水迷路における同時神経刺激および記録のためのコスト効率のヘッドステージの設計と構築

09:09

水迷路における同時神経刺激および記録のためのコスト効率のヘッドステージの設計と構築

Related Videos

11.1K Views

VisualEyes:眼球運動実験のためのモジュラ式のソフトウェアシステム

10:41

VisualEyes:眼球運動実験のためのモジュラ式のソフトウェアシステム

Related Videos

13.3K Views

鳴禽類には聴覚フィードバックを操作するための軽量、ヘッドフォンベースのシステム

10:13

鳴禽類には聴覚フィードバックを操作するための軽量、ヘッドフォンベースのシステム

Related Videos

14.8K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code