-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

KR

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

ko_KR

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Neuroscience
마우스의 통증 행동을 측정하기위한 기계적 충돌 회피 분석
마우스의 통증 행동을 측정하기위한 기계적 충돌 회피 분석
JoVE Journal
Neuroscience
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Neuroscience
Mechanical Conflict-Avoidance Assay to Measure Pain Behavior in Mice

마우스의 통증 행동을 측정하기위한 기계적 충돌 회피 분석

Full Text
4,304 Views
06:57 min
February 18, 2022

DOI: 10.3791/63454-v

Caitlyn M. Gaffney1, Gabriella Muwanga2, Huaishuang Shen2, Vivianne L. Tawfik2, Andrew J. Shepherd2

1Laboratories of Neuroimmunology, Department of Symptom Research, and the MD Anderson Pain Research Consortium,University of Texas MD Anderson Cancer Center, 2Department of Anesthesiology, Perioperative and Pain Medicine,Stanford University School of Medicine

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

The mechanical conflict-avoidance assay is a behavioral test designed to measure pain sensitivity in mice. This method helps in understanding how different pain conditions affect the motivational state of animals, offering insights into their affective responses. Its simplicity and speed make it a valuable tool for enhancing preclinical research translation.

Key Study Components

Area of Science

  • Neuroscience
  • Behavioral Analysis
  • Pain Models

Background

  • The need for effective pain assessment methods in animal models.
  • Evaluating affective-motivational responses related to pain.
  • The importance of translating preclinical findings to clinical settings.

Purpose of Study

  • To refine the assessment of pain sensitivity in mouse models.
  • To evaluate the operational mechanisms and motivations in response to pain.
  • To develop a method that enhances preclinical research efficacy.

Methods Used

  • The study employs a mechanical conflict-avoidance assay in a specially constructed chamber.
  • Mice are acclimated and tested under varying mechanical probe heights to assess their escape latency.
  • Key steps include chamber construction, mouse acclimatization, and systematic recording of response times.

Main Results

  • Increased escape latency indicates heightened pain sensitivity in various models.
  • Responses varied significantly with probe height, highlighting the complexity of pain response influenced by external factors.
  • Pre-treatment with analgesics showed a notable effect on latency outcomes, indicating potential pathways for pain management.

Conclusions

  • This study demonstrates the utility of the mechanical conflict-avoidance assay in assessing pain sensitivity in mice.
  • The method facilitates a deeper understanding of pain mechanisms, aiding in the translation of findings to subsequent research.
  • Insights garnered from this method could inform strategies for pain management and enhance preclinical model efficiency.

Frequently Asked Questions

What are the advantages of the mechanical conflict-avoidance assay?
The assay is relatively quick and easy to perform while providing a detailed assessment of complex motivations influencing pain-related behavior in mice.
How is the main biological model implemented?
Mice are acclimated to a specially designed chamber where their response to mechanical probes of varying heights is recorded to measure pain sensitivity.
What type of data is obtained from this assay?
Key outcomes include latencies to escape and dwell times in different chambers, which reflect the motivational state of the mice under various pain conditions.
Can the method be adapted for other pain models?
Yes, this method can be used alongside different pain models, such as inflammatory and neuropathic pain models, allowing for a broader application in pain research.
What are key limitations of this assay?
Important considerations include ensuring proper habituation of mice to the device and maintaining randomization and blinding throughout testing to avoid bias.
How does this method contribute to understanding pain mechanisms?
By measuring motivational responses to pain, the assay offers insights into the underlying neural mechanisms and behavioral adaptations in response to pain in mice.

기계적 충돌-회피 분석은 다양한 마우스 통증 모델에서 정서적-동기 부여 반응을 더 잘 이해하기 위해 사용될 수 있는 마우스에서 통증 감수성의 비반사적 판독으로서 사용된다.

이 방법은 다른 통증 조건에서 동물의 효과적 또는 동기 부여 상태에 대한 질문에 대답하는 데 도움이 될 수 있습니다. 그것은 전임상 연구의 번역을 개선하는 중요한 단계입니다. 이 기술의 가장 큰 장점은 비교적 빠르고 쉽게 수행 할 수 있지만 통증 관련 행동에 영향을 미치는 복잡한 동기를 평가한다는 것입니다.

불투명 한 흰색 세 밀리미터 두께의 아크릴을 사용하여 챔버의 측벽, 바닥 및 천장을 구성하는 것으로 시작하십시오. 정면을 향한 벽의 경우 투명한 세 밀리미터 두께의 아크릴을 사용하십시오. 챔버의 뚜껑을 힌지로 부착하여 마우스를 챔버에 쉽게 넣고 챔버에서 회수 할 수 있도록하십시오.

그런 다음 자체 접착식 발광 다이오드 테이프를 뚜껑의 내부 표면에 부착하여 약 4, 800lux의 조명을 제공합니다. 불투명 아크릴 시트를 다른 MCA 장치로부터 챔버 하나를 닫을 수 있도록 위치 안팎으로 밀어 넣습니다. 다음으로, 270 밀리미터 길이의 조명이 켜지지 않은 챔버 2 개, MCA 테스트 챔버를 상단에 힌지 뚜껑이있는 사방에 반투명 진한 빨간색 아크릴을 사용하여 구성하십시오.

그런 다음 챔버 바닥에 두 밀리미터 구멍이있는 13 x 31 그리드를 배치하여 직경 0.5 밀리미터 팁의 무딘 프로브 배열이 돌출 될 수 있습니다. 프로브 베이스 플레이트 아래에 아크릴 시트를 추가로 배치하여 프로브의 높이를 조정합니다. 이 방법을 사용하여 프로브 높이가 0, 두 밀리미터 및 다섯 밀리미터로 장치를 구성합니다.

무딘 지도 핀 또는 유사한 재료에 대한 대안으로 3D 프린터 파일을 사용하여 나일론 12 플라스틱과 같은 세척 가능하고 생체 적합성 재료로 챔버 2 및 프로브 플레이트의 바닥을 인쇄하십시오. 마지막으로, 방과 비슷한 힌지 뚜껑이있는 모든면에 반투명 진한 빨간색 아크릴을 사용하여 어두운 챔버 세 개를 구성하십시오. 챔버 하나의 반대쪽 끝에 배치하여 챔버 두 개의 기계적 프로브에서 어두운 탈출 영역으로 사용하십시오.

기준선 테스트를 스케줄링하기 하루 전에, 전체 장치의 사회적 탐구를 용이하게하기 위해 케이지 메이트와 함께 5 내지 15 분 동안 마우스를 MCA 유닛에 적응시킨다. 챔버 하나의 LED가 꺼져 있는지, 챔버 하나와 두 개 사이의 장벽이 열린 상태로 유지되고 프로브가 챔버 두 개의 바닥을 통해 돌출되지 않았는지 확인하십시오. 다음으로, 전체 MCA 장치의 측면 뷰가 있는 삼각대에 1080픽셀 푸티지를 녹화할 수 있는 비디오 카메라를 설정합니다.

MCA가 녹화된 이미지를 채우도록 시야를 조정합니다. 녹화가 시작되면 카메라의 필드 뷰에 핸드헬드 드라이 지우기 보드를 잡고 동물의 테스트 실행에 대한 식별 정보와 함께 비디오의 시작 부분에 레이블을 지정합니다. 첫 번째 실행의 경우 프로브 높이를 0으로 설정하고 테스트 할 마우스를 홈 케이지에서 장벽 도어가 설치된 챔버로 옮깁니다.

녹화된 푸티지에 표시되는 타이머를 시작합니다. 10초 후 챔버에 LED 하나를 켭니다. 마우스가 20초 동안 점등된 챔버에 들어간 후, 챔버 하나와 두 개 사이의 장벽을 철회한다.

두 분 동안 동물을 관찰하고 테스트가 진행되는 동안 스톱워치로 대기 시간 또는 체류 시간을 측정하십시오. 챔버 두 개에 대한 첫 번째 진입까지의 대기 시간, 챔버 두 개를 가로 질러 절반 이상을 횡단하는 대기 시간, 챔버 두 개의 총 체류 시간, 챔버 세 개에 도달하는 대기 시간, 두 분 이내에 각 챔버의 총 체류 시간을 기록하고 비율로 변환하십시오. 테스트가 완료되면 마우스를 홈 케이지로 되돌립니다.

MCA 챔버를 70 % 에탄올로 청소하고 완전히 건조시킵니다. 프로브 높이가 0으로 설정된 코호트에서 모든 마우스를 실행한 후, 기계적 프로브 베이스 플레이트 아래에 세 밀리미터의 아크릴 시트를 삽입하고 두 밀리미터의 프로브 높이로 실행을 반복합니다. 프로브 높이가 두 밀리미터로 설정된 모든 마우스를 실행한 후, 프로브 베이스 플레이트 아래에 또 다른 세 밀리미터의 아크릴 시트를 삽입하고 프로브 높이가 다섯 밀리미터인 상태에서 실행을 반복합니다.

테스트 세션이 끝날 때 소독제로 최종 청소를 수행하십시오. 완전한 프로인트의 아주반트-유도된 염증성 통증 모델에서, 식염수 주사는 기준선에 비해 탈출 지연시간을 변화시키지 않는다. 애쥬번트를 주사한 마우스는 주사 후 나흘 동안 탈출 레이턴시의 현저한 증가를 나타냈지만, 프로브 높이가 다섯 밀리미터로 상승되었을 때만 나타났다.

이러한 증가된 잠복기는 시험 시작 90분 전에 카프로펜을 투여받은 마우스에서는 나타나지 않았다. 신경병증성 통증의 보존된 신경 손상 모델은 프로브 높이가 다섯 밀리미터로 설정되었을 때 기준선 대비 탈출 대기 시간을 상당히 증가시켰다. 이러한 증가는 시험 90분 전에 오피오이드 진통제 부프레노르핀의 투여에 의해 방지되었다.

증가된 탈출 잠복기는 또한 신경 손상 전에 MCA 시험의 기준선 라운드를 겪지 않은 마우스에서 관찰되었다. 다섯 밀리미터에서 절약된 신경 손상 마우스에서 증가된 탈출 잠복기는 시험 90분 전에 가바펜틴 투여에 의해 예방되었다. 파단 또는 주조 모델에서, 챔버로부터 탈출하기 위한 레이턴시는 손상 전에 프로브 높이에 비례하여 증가하였다.

부상 후 대기 시간은 0 밀리미터에서 변하지 않았지만 기준선과 비교할 때 남성의 경우 두 밀리미터 및 다섯 밀리미터 프로브 높이와 여성의 경우 다섯 밀리미터 프로브 높이에서 크게 증가했습니다. 이 절차를 시도 할 때 기억해야 할 가장 중요한 것은 모든 마우스가 MCA 장치에 습관화되어 있는지 확인하고 연구 전반에 걸쳐 적절한 무작위 배정 및 블라인드닝을 유지하는 것입니다. 이 방법은 폰 프레이 (von Frey) 또는 조건부 장소 선호도를 포함한 통증 민감성의 다른 측정과 함께 사용할 수 있습니다.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

신경과학 제180호

Related Videos

통각 행동의 변화를 측정하는 조작 적 구강 안면 통증 평가 장치 (OPAD)의 사용

12:20

통각 행동의 변화를 측정하는 조작 적 구강 안면 통증 평가 장치 (OPAD)의 사용

Related Videos

21.9K Views

열 및 기계를 침해 수용성 모달리티를 사용하여 마우스의 모르핀에 의한 통각 과민과 진통 공차의 평가

07:23

열 및 기계를 침해 수용성 모달리티를 사용하여 마우스의 모르핀에 의한 통각 과민과 진통 공차의 평가

Related Videos

34.1K Views

마우스에서 관절염 통증의 Monoiodoacetate 모델

09:26

마우스에서 관절염 통증의 Monoiodoacetate 모델

Related Videos

37.9K Views

만성 통증 치료에 재조합 단백질의 개발

10:37

만성 통증 치료에 재조합 단백질의 개발

Related Videos

10K Views

Murine 모델 Monoarticular 무릎 통증의 통증의 자연과 갖는 측정

08:03

Murine 모델 Monoarticular 무릎 통증의 통증의 자연과 갖는 측정

Related Videos

8.9K Views

로봇 팔에 도달하는 패러다임을 사용하여 통증 관련 회피 행동 조사

09:00

로봇 팔에 도달하는 패러다임을 사용하여 통증 관련 회피 행동 조사

Related Videos

4.5K Views

만성 요통의 기계론적 조사를 위한 쥐의 등 기계적 민감도 평가

05:10

만성 요통의 기계론적 조사를 위한 쥐의 등 기계적 민감도 평가

Related Videos

3.5K Views

우로키나아제(Urokinase)형 플라스미노겐 활성제(Plasminogen Activator)에 의한 생쥐 요통 모델

06:20

우로키나아제(Urokinase)형 플라스미노겐 활성제(Plasminogen Activator)에 의한 생쥐 요통 모델

Related Videos

1.7K Views

구강 안면 조작 통증 분석을 사용한 쥐의 신경 손상 유발 기계적 과민증 평가

07:39

구강 안면 조작 통증 분석을 사용한 쥐의 신경 손상 유발 기계적 과민증 평가

Related Videos

4.2K Views

생쥐의 진통 효과를 연구하기 위해 수정된 염증성 통증 모델

06:54

생쥐의 진통 효과를 연구하기 위해 수정된 염증성 통증 모델

Related Videos

2.7K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code