Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Grafting Pancreatic Islets: A Method to Implant Pancreatic Islets into the Anterior Chamber of the Mouse Eye for In Vivo Imaging

1.4K weergaven

⸱

30 april 2023

In dit artikel

Samenvatting

Source: Nilsson, J.et. al. A Longitudinal In Vivo Imaging and Quantification of Human Pancreatic Islet Grafting and Contributing Host Cells in the Anterior Eye Chamber. J. Vis. Exp. (2020).

This video describes the protocol for grafting human pancreatic islets into the anterior chamber of the mouse’s eye to monitor revascularization of human islet grafts in vivo. It also helps to understand the contribution of recipient versus donor cells in promoting the encapsulation and vascularization of the graft.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the jove veterinary review board

1. Preparation of transplantation equipment and surgery table

NOTE: All surgical tools should be autoclaved, and the surgery table and instruments disinfected with 70% alcohol.

  1. Connect a stereotaxic head holder to anesthesia via a nose mask and turn on the heating pad.
  2. Connect a gastight Hamilton syringe to polyethylene tubing and a blunt end eye cannula.
    NOTE: It is recommended to fill all pa....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Mouse pancreatic islet extraction setup; microscope and islet comparison, research experiment.
Figure 1: Transplantation of pancreatic islets into the anterior chamber of the eye.
(a) Transplantation setup showing anesthetized mouse fixed in stereotaxic head holder and the exposed eye (inset) next to the prepared.......

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Clean Bench coat
Heating padSet to 37 °C
Ivis Lumina ll Bioluminescent imagerCaliperAlternative bioluminescent imaging systems include&nbsp;<em>In vivo</em>&nbsp;F PRO (Carestream) and Photon Imager (Biospace Lab)