Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Filament Insertion-based Transient Stroke Model: A Surgical Procedure to Perform Middle Cerebral Artery Occlusion in Murine Brain

4.3K weergaven

⸱

8 juli 2025

In dit artikel

Samenvatting

Source: Llovera, G., et al. Modeling Stroke in Mice: Transient Middle Cerebral Artery Occlusion via the External Carotid Artery. J. Vis. Exp (2021).

This video describes the procedure to develop transient stroke in a murine model using silicon-coated filament-based occlusion of the middle cerebral artery. The developed model mimics human stroke, thus helping to investigate novel therapeutic strategies for treating stroke.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation of the material and instruments

  1. Connect the heat blanket to maintain the temperature of the operation area and the mouse body temperature during anesthesia at 37 °C.
  2. Autoclave scissors and forceps, prepare 70% ethanol solution and keep available dexpanthenol eye ointment, several pieces of cotton, and 5-0 coated braided polyester suture ready for use. Prepare a 1 mL syringe with 0.9% saline solution (without needle) to keep....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
45° rampH&S Kunststofftechnikheight: 18 cm
5/0 threatPearsalls10C103000
Anesthesia system for isofluraneDrager
Bepanthen pomadeBayer
C57Bl/6J miceCharles River000664
ClampFST12500-12
ClipFST18055-04
Clip holderFST18057-14
CottonsNOBA Verbondmitel Danz974116
Ethanol 70%CLN Chemikalien Laborbedorf521005
Ethanol 96%CLN Chemikalien Laborbedorf522078
Ethanol 99%CLN Chemikalien LaborbedorfETO-5000-99-1
FilamentsDoccol602112PK5Re
Fine 45 angled forcepsFST11251-35
Fine forcepsFST11252-23
Fine ScissorsFST14094-11
GlueOrechselnBSI-112
Hardener GlueDrechseln & MehrBSI-151
Heating blanketFHC DC Temperature Controller
IsofluraneAbbotB506
IsopentaneFluka59070
Laser DopplerPerimedPF 5010 LDPM, Periflux System
5000
Laser Doppler probePerimed91-00123
Recovery chamberMediheat
Silicon-coated filamentsDoccol602112PK5Re
Vannas Spring ScissorsFST15000-00

Meer artikelen verkennen