All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Sterilization
- CRITICAL STEP: Disinfect all forceps and scissors by soaking for 1 h in 5% (v/v) solution of Distel in distilled water, clean with a brush, rinse with tap water and sterilize in an oven at 185 °C for a minimum of 2 h.
- Sterilize all other glassware and reagents by autoclaving at 121 °C for 15 minutes or prepare reagents according to the manufacturer's instructions. Carry out the following procedures in a class II microbiology safety cabinet.
2. Sample collection
- Collection of porcine eyes
- Large white landrace sows, a cross with a Hampshire boar was used. The animals were stunned with an electric current and the eyes were enucleated 2 h later in the abattoir.
- CRITICAL STEP: Once enucleated, transfer the eyes to the lab in a sterile phosphate buffered saline (PBS) solution to prevent them from drying out and process them immediately upon arrival.
3. Preparation of the corneoscleral button
- Use sterile forceps to hold the tissue surrounding the eyeball and transfer it to a Petri dish. Remove the conjunctiva and muscle tissue around the eyeball on a Petri dish using scalpel blade no. 15 and forceps.
- Gently lift the eyeball while holding the optic nerve with forceps and transfer to a 0.5 L jar filled with sterile PBS.
- Once all eyes are cleared of surrounding tissue, move them using sterile forceps to another 0.5 L jar filled with 3% (v/v) povidone iodine in PBS and leave for 1 min.
- Transfer eyeballs to another 0.5 L jar with sterile PBS.
- Use forceps to hold the eye still on a Petri dish and make a cut near the cornea with a scalpel blade no 10A.
- CRITICAL STEP: Hold the edge of the cut and use scissors to excise the cornea leaving about 3 mm of sclera surrounding the cornea. Ensure the sharp end of scissors does not pierce the iris or the choroidal tissue and is in the supra-choroidal space.
- Hold the corneoscleral button with forceps and use another pair of pointed end forceps to gently separate the uveal tissue.
- Lift the corneoscleral button from remaining globe and briefly rinse it in 1.5% (v/v) povidone iodine solution in PBS in a 12 well plate.
- Place the corneoscleral button into another 12 well plate filled with sterile PBS.