Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Capillary Electrophoresis: A Technique to Analyze Fluorescently Labeled Polymerase Chain Reaction Amplicons

2.9K weergaven

8 juli 2025

In dit artikel

Samenvatting

Source: Gulla, S. et al., Multi-locus Variable-number Tandem-repeat Analysis of the Fish-pathogenic Bacterium Yersinia ruckeri by Multiplex PCR and Capillary Electrophoresis. J. Vis. Exp. (2019)

This video describes the technique of capillary electrophoresis to analyze fluorescently labeled PCR amplicons obtained from various samples based on their size. It generates a migratory pattern that determines the fragments’ base-pair lengths with the help of the labeled fluorescent dye in each fragment.

Protocol

1. Capillary Electrophoresis Setup and Run Conditions

  1. Following confirmation of PCR amplicons, dilute PCR products 1:10 (v/v) in purified water. Seal, mix and centrifuge briefly.
  2. Working in a fume cupboard, prepare a volume of master mix consisting of 9 µL of formamide and 0.5 µL of size standard per PCR product (allow 10% surplus volume). Vortex briefly and distribute 9.5 µL into wells on a plate appropriate for the available CE system before adding 0.5 µL of diluted PCR product. Seal, mix and centrifuge briefly.
    CAUTION: Handle with care. Mixing formamide with water generates formic acid, which is toxic.
  3. Using a PCR thermal cycler, denature the samples at 95 °C for 3 min before cooling to 4 °C indefinitely. Centrifuge briefly and load the plate onto a calibrated CE system according to the manufacturer’s instructions.
  4. Run fragment analysis CE using reagents as appropriate for the apparatus of choice and the following settings: 60 °C; 5 s injections at 1.6 kV (32 V per cm); 32 min run time at 15 kV (300 V per cm). CE fragment analysis of 24 wells on a 24-capillary (50 cm) will typically take approximately 50 min.

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Avant 3500xL Genetic AnalyzerThermo Fisher ScientificA30469Used for capillary electrophoresis fragment analysis.
GelRed Nucleic Acid Stain, 10,000X in waterBiotium41003Fluorescent nucleic acid dye used during gel electrophoresis.
GeneMapper Software 5Thermo Fisher Scientific4475073Used for reading electropherograms from capillary electrophoresis.
GeneScan 600 LIZ dye Size Standard v2.0Thermo Fisher Scientific4408399Size standard used during capillary electrophoresis.
Hi-Di FormamideThermo Fisher Scientific4311320/4440753Deionized formamide used during capillary electrophoresis. Prepare working aliquouts.
Milli-Q waterNANAPurified water used during PCR and capillary electrophoresis. Standard recipe; produced inhouse.
POP-7 Polymer for 3500 Dx/3500xL Dx Genetic AnalyzersThermo Fisher ScientificA26077/4393713/4393709Separation matrix used during capillary electrophoresis.
UV-based gel imaging/visualisation systemAs preferred.NA
VortexerAs preferred.NA

Trefwoorden

Fluorescerend gelabelde PCRDNA fragmentanalysevergelijking met groottestandaardelektrokinetische injectiepolymeergelcapillairlaserdetectiesysteemanalysepiek van het electroferogramformamide denaturatiestapverdunning van PCR product