Source: Guo, L. et. al., Assays for the Degradation of Misfolded Proteins in Cells. J. Vis. Exp. (2016)

This video describes an in vitro fluorescence-based microplate assay to study the degradation kinetics of a fluorescently-labeled misfolded luciferase mutant protein expressed in the nuclei of transfected mammalian cells. The assay involves the treatment of cells expressing the fluorescent mutant protein with a translation inhibitor and a proteasome inhibitor to assess the proteasome-mediated degradation of the misfolded protein.

Protocol

1. ​Preparation of Reagent

  1. Prepare low-fluorescence DMEM medium for assays using a microplate fluorescence reader. Mix 25 mM glucose, 0.4 mM glycine, 0.4 mM arginine, 0.2 mM cysteine, 4.0 mM glutamine, 0.2 mM histidine, 0.8 mM isoleucine, 0.8 mM leucine, 0.8 mM lysine, 0.2 mM methionine, 0.4 mM phenylalanine, 0.4 mM serine, 0.8 mM threonine, 0.078 mM tryptophan, 0.4 mM tyrosine, 0.8 mM valine, 1.8 mM CaCl2, 0.81 mM MgSO4, 5.33 mM KCl, 44.0 mM NaHCO3, 110 mM NaCl, 0.9 mM NaH2PO4. Adjust the pH of the solution using HCl or NaOH to pH 7.4. Sterilize the medium through filtration.
    NOTE....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Protein degradation analysis, fluorescence intensity graphs comparing CHX and CHX+MG132 over time; microscopy results show cellular fluorescence changes at different treatments.
Figure 1: Fluorescent microplate-based assay for NLS-LucDM-GFP degradation. HeLa cells .......

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Dulbecco's Modified Eagle MediumLife Technologies11995-092
Fetal Bovine SerumLife Technologies10082147
Lipofectamine 2000Life Technologies11668019
MG132Sigma-AldrichM8699
Amino acidsSigma-AldrichAmino acids are used for making low fluorecence culturing medium
CycloheximideSigma-AldrichC7698
Olympus IX-81 Inverted Fluorescence MicroscopeOlympusIX71/IX81
96 Well Black TC Plate w/ Transluscent Clear BottomSigma-Greiner89135-048
Fluorescence Bottom Plate Reader Infinite 200® PROTECANInfinite 200® PRO
Prism 5GraphPadStatistical analysis software