Methodenartikel

Bioreporter Assay: A Sensitive Technique using a Bioluminescent Reporter System to Detect SARS-CoV-2 Antibodies

782 weergaven

8 juli 2025

In dit artikel

Samenvatting

Source: Rezaei, R. et al., Detection of SARS-CoV-2 Receptor-Binding Domain Antibody using a HiBiT-Based Bioreporter. J. Vis. Exp. (2021)

In this video, we show the HiBit-RBD bioreporter system-based assay for detecting SARS-CoV-2 neutralizing antibodies. This system targets the viral RBD domain by using a bioluminescent reporter system containing HiBiT fused to the RBD domain.

Protocol

1. Detecting anti-RBD antibody with a fast and sensitive assay

  1. HiBiT-RBD antibody detection assay
    1. Prepare the HiBiT-RBD bioreporter.
      NOTE: It is recommended to use the supernatant for the following assay as it is simpler to collect and contains the mature glycosylated version of the protein. Moreover, the lysate has several other proteins that could interfere with the HiBiT-RBD-antibody interaction.
    2. Combine 50 µL of the HiBiT-RBD-containing supernatant with 1 µg of the commercial SARS-CoV-2-RBD antibody in a 1.5 mL microtube. Add 20 µL of immunoglobulin-binding protein (protein G) to the solution. Bring up the total volume to 300 µL by adding PBS.
      NOTE: The total volume of the mixture can be decreased to 150 µL. Lower total volumes are not recommended as it could result in inadequate mixing of antibodies with the bioreporter.
    3. Incubate the tube(s) on a tube shaker or rotator for 30 min. Centrifuge at 12,000 x g for 30 s, discard the supernatant and wash with PBS. Repeat the process three times to remove free HiBiT-RBD. Resuspend in 50 µL of PBS and transfer to a 96-well plate.
    4. Add 50 µL of 1x LgBiT and wait for 5 min. Then, add 50 µL of 1x NanoLuc substrate. Immediately read the luminescent signal with a luminometer.

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Bio-Plex Handheld Magnetic WasherBio-Rad171020100Device
Dual-Glo luciferase Assay SystemPromegaE2940100 mL kit
LgBiTPromegaN3030Assay kit
Pierce Protein G Magnetic BeadsThermo Fisher Scientific88848Assay
SARS-CoV-2 (2019-nCoV) Spike Neutralizing Antibody, Mouse MabSinoBiological40592-MM57Assay
Synergy Mx Microplate ReaderBioTek96-well plate reader luminometer

Herprints en machtigingen

Toestemming aanvragen om de tekst of afbeeldingen van dit JoVE-artikel te hergebruiken

Toestemming aanvragen

Trefwoorden

HiBiT RBD systeembioluminescente detectieRBD bindingProte ne G beadsLgBiT substraatfurimazine oxidatieluminometermetingneutraliserende antilichamen