Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

A Technique to Purify Monoclonal Antibodies Produced by Chinese Hamster Ovary Cells

1.2K weergaven

⸱

8 juli 2025

In dit artikel

Samenvatting

Source: Velugula-Yellela, S. R., et al. Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System. J. Vis. Exp. (2019).

This video demonstrates an assay for purifying monoclonal antibodies from cell culture fluid harvested from Chinese Hamster Ovarian cells. It employs a porous glass resin with immobilized protein A, which binds to the Fc region of the antibodies in the sample, effectively separating them from contaminants. The use of a low-pH elution buffer weakens the interaction, facilitating the retrieval of purified antibodies.

Protocol

1. Purification of antibody

NOTE: The equilibration buffer for the in-house antibody is 25 mM Tris, 100 mM NaCl, pH 7.5. The elution buffer used is 0.1 M acetic acid. The buffers and resin (Protein A) are dependent on the specific antibody purified. Column volume is equivalent to the bed height of the resin. The amount of mobile phase used is determined in terms of column volume.

  1. Initializing the purification system
    1. Open the software attached to the purification system. Using manual instructions, equilibrate the column with the equilibration buffer at a flow rate of 2 mL/min for 40 min. Stop the manual run after equilibration.
    2. In the fraction collector, place 15 mL conical tubes to collect purified antibody eluate and 50 mL conical tubes to collect flow-through during high salt wash. Ensure that the fraction collector is reset to the start position by opening and closing the fraction collector before the beginning the run. The fraction collector is maintained at 7 °C.
      NOTE: The fraction collector can be reset manually under the Fraction Collector tab in Settings, for both 15 mL and 50 mL tubes.
  2. Sample injection
    NOTE: The harvested cell culture fluid used in the following procedures has been obtained from chinese hamster ovary cells cultured in automated micro-bioreactors.
    1. Add the 0.22 µm filtered harvest cell culture fluid to an empty 12 mL syringe whose nozzle end is capped.
    2. Holding the syringe with the nozzle facing down, insert the syringe plunger till a small portion of the plunger is in. Making sure that the fluid is not leaking, turn the syringe with the nozzle facing up and remove the cap.
    3. Still holding the syringe with the nozzle facing up, push the cylinder to dispel any air until the cell culture fluid is at the tip of the nozzle. Insert the syringe nozzle into the manual injection port on the purification system and twist to tighten.
    4. Push down on the plunger until all the sample is injected and is visible in the attached 10 mL large volume sample loop.
    5. Open the saved method file. Save the result file in the required location and specify file name when prompted. Hit run after the sample has been injected into the large volume sample loop.
  3. Running the purification method
    1. Select the saved method and click run when prompted by instrument software (step 1.2.5).
      NOTE: The system is set up to run the following steps. The user needs not do anything while the instrument is running.
    2. Equilibrate the column with three column volumes (CVs) of equilibration buffer at a flow rate of 2 mL/min. Once the column is equilibrated, the system, using the large volume sample loop, will inject the sample onto the column at a flow rate of 1 mL/min.
    3. A drop in UV signal at 280 nm indicates that the sample is finished loading. Wash the column with equilibration buffer at a flow rate of 2 mL/min until the UV signal drops below 25 mAU.
    4. Use four CVs of 25 mM Tris with 1 M NaCl at pH 7.5 to perform a secondary high salt wash at a flow rate of 2 mL/min. The system fraction collector will collect any protein/DNA that comes off the column during the salt wash in 50 mL tubes.
    5. Apply five CVs of elution buffer at a flow rate of 1 mL/min to elute the antibody off the column. Collect the eluate in 15 mL tubes based on UV signal; when the UV 280 signal is above 35 mAU, collection starts; collection ends when the signal drops below 50 mAU; this is called peak cutting.
      NOTE: Peak cutting ensures normalization of elution profiles and to avoid elution peak tailing which may contain protein aggregates.
    6. Wash the column using three CVs of equilibration buffer. The run ends after the wash step.
    7. After elution immediately neutralize the purified protein using 1 M Tris base to a pH of ~5.5. Measure the protein concentration using a microvolume UV-Vis spectrophotometer at 280 nm and 260 nm and store at 4 °C.

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
CHO DG44 Cell LineInvitrogenA1100001
Akta Avant 25General Electric Life Sciences28930842
Pro Sep vA Ultra Chromatography ResinMillipore Sigma115115830Purification Stationary Phase
Omnifit 10cm ColumnDiba Fluid Intelligence006EZ-06-10-AAHousing for Stationary Phase
Tris BaseFisher ScientificBP154-1
Superloop 10 mLGE Healthcare18-1113-81
µDawn Multi Angle Light Scattering DetectorWyattWUDAWN-01
0.22 µm Millex GV Filter Unit PVDF MembraneMerck MilliporeSLGV033RB
10X Phosphate Buffered SalineCorning46-013-CM
12 mL SyringeCovidien8881512878
50 mL Falcon tubeCorning Inc.352070
96-Well PlateBio-Rad127737
Acetic AcidSigma-Aldrich695072
Amicon Ultra-4 100 kDa centrifugal filtersMerck MilliporeUFC810096
Amino Acid Standard, 1 nmol/µLAgilent Technologies5061-3330
Amino Acid SupplementAgilent Technologies5062-2478
Ammonium Formate Solution - Glycan AnalysisWaters Corporation186007081
Blue Screw Caps with SeptaAgilent Technologies5182-0717
Chromatography Water (MS Grade)Fisher ChemicalW6-4
Hydrochloric AcidFisher ScientificA144-500
Intact mAb Mass Check StandardWaters Corporation186006552
Intrada Amino Acid Column 150 x 2 mmImtaktWAA25
NanoDrop One Microvolume UV-Vis SpectrophotometerThermo Fisher Scientific840274100

Tags

Zuivering van monoklonale antilichamenproteïne A-chromatografieFPLC-kolomelutie bij lage pHwassing met hoog zoutgehalteFc-regio van antilichaamgeautomatiseerde microbioreactorneutralisatie met Tris-basecelkweekvloeistof