Source: Perrenoud, L. et al., Analysis of T-cell Receptor-Induced Calcium Influx in Primary Murine T-cells by Full Spectrum Flow Cytometry. J. Vis. Exp. (2022)

This video analyzes T-cell receptor-induced calcium influx in T-cells. Anti-CD3 antibodies activate the T-cell signaling pathways, leading to an increase in intracellular calcium ions that bind with Indo-1 dye. In flow cytometry, a spectrum shift from the calcium-free state to the calcium-bound state  correlates with T-cell receptor-induced calcium influx.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation of immune cells from the mouse spleen

NOTE: Euthanize naïve mice with carbon dioxide (CO2) euthanasia. C57BL/6 mice purchased from Jackson Laboratories and bred in-house are used for experiments at 6-12 weeks of age. Both male and female mice are utilized for experiments.

  1. Disinfect the mouse skin with 70% ethanol in order to reduce the possibility of external contaminants from getting into ....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
12 well TC treated platesCell Treat229111
50 mL conicalGreiner Bio141-12-17-0350 mL Polypropylene centrifuge tubes with cap
5mL polysterene flow tubesCorning352052
5mL syringeBD syringe309646plunger only is used sheith is discarded
70uM filterGreiner bio1542070
aCD3 (17A2)Biolegend100202
AKC lysis BufferGibcoA1049201
Aurora Spectral Flowcytometerhttps://cytekbio.com/pages/aurora
Bath BeadscoleparmerItem # UX-06274-52
CD19 PETonbo50-0193-U100
CD1d Tetramer APCNIH
CD25 PECy7ebioscience15-0251
CD4 APC Cy7Tonbo25-0042-U100
CD8a FITCebioscience11-0081-85
Cell IncubatorFormal Scientific
Dissection Tools forcepsMcKesson#487593Tissue Forceps McKesson Adson 4-3/4 Inch Length Office Grade Stainless Steel NonSterile NonLocking Thumb Handle 1 X 2 Teeth
Dissection Tools ScissorsMcKesson#970135Operating Scissors McKesson Argent™ 4-1/2 Inch Surgical Grade Stainless Steel Finger Ring Handle Straight Sharp Tip / Sharp Tip
DPBS 1xGibco14190-136DPBS 
EGTAFisherNC1280093
FBSHyclondSH30071.03lot AE29165301
FlowJo Softwarehttps://www.flowjo.com/
Indo1-AM Ester Dyeebioscience65-085-39Calcium Loading Dye 
IonomycinMillipore407951-1mg
Live/Dead Ghost 540Tonbo13-0879-T100
Microcentrifuge tubes 1.7mLLight LabsA-7001
Penicillin/Streptomycin/L-GlutamineGibco10378-016
PRN694Med Chem ExpressHy-12688
Purified Anti-Mouse CD16/CD32 (FC Shield) (2.4G2)Tonbo70-0161-M001FC Block
RPMIGibco1875093 + phenol red
RPMI phenol freeGibco11835030 -phenol red
Table top centrifugeBeckman CoulterAllegra612
TCRβ PerCP Cy5.5ebioscience45-5961-82
TCRγ/δ Pe Cy5ebioscience15-5961-82
Vi-Cell Blu Reagent PackProduct No: C06019Includes Tripan
Vi-Cell BluBeckman Coulter
WaterbathFisher Brand Dry bath

Tags