Source: Terzi, A. et al., ROS Live Cell Imaging During Neuronal Development. J. Vis. Exp. (2021).

This video demonstrates a technique to detect real-time hydrogen peroxide levels in retinal ganglion cells using the roGFP2-Orp1 biosensor and live cell imaging techniques. It outlines the steps involved in cell preparation, fluorescence imaging, and the quantification of hydrogen peroxide levels.

Protocol

1. In vitro reactive oxygen species (ROS) imaging of cultured retinal ganglion cell (RGC) neurons

  1. On the day of imaging (typically 6-24 h after cell plating), check retinal ganglion cells under a microscope to validate the growth of RGC axons.
  2. For live-cell imaging, transfer coverslips from the culture dish to a live cell imaging chamber.
  3. Set up microscope for imaging. Use an inverted microscope equipped with a differential interference contrast (DIC) objective, OG590 long-pass red filter, and an EM-CCD camera.
  4. Before imaging, replace the zebrafish cell culture medium with serum and antibiotics (ZFCM)(+)) with zebrafish cell culture medium without serum and antibiotics (ZFCM(-)).
  5. Once cells are positioned with 10x objective, acquire images at 60x magnification using a high NA oil immersion objective. Use an additional 1.5x magnification.
  6. First, acquire DIC images. Then, image roGFP2-Orp1 using an appropriate filter set. Excite roGFP2-Orp1 with 405/20 and 480/30 nm excitation filters sequentially and acquire images with 535/30 nm emission filter after emission light has passed the dichroic mirror 505DCXR.
  7. After taking the first set of images, exchange media with media containing different treatment solutions. The media should be changed every 30 minutes of imaging to avoid pH and osmolarity changes.

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
35-mm culture dishSarstedt83-3900
Cover glassCorning2850-22
Disposable Petri Dishes (100 x 15 mm)VWR25384-094
Fetal Bovine SerumThermoFisher Scientific26140087
Inverted MicroscopeNikonTE2000
LamininThermoFisher Scientific23017-015
Leibovitz's L-15 Medium with phenol redGibco/Fisher Scientific11-415-064
Leibovitz's L-15 Medium without phenol redGibco/Fisher Scientific21-083-027
Penicillin/streptomycinThermoFisher Scientific15140122
Phenol RedSigma AldichP0290
Poly-D-Lysine (PDL)Sigma AldichP7280
Steritop 0.22 µm filterMilliporeS2GPT05RE
Calcium Chloride Dihydrate Fisher Scientific C79-500
Glucose Sigma Aldrich G7528
HEPES Sigma Aldrich H4034

Tags

Waterstofperoxidedetectielive cell imagingroGFP2 Orp1 biosensorfluorescentie intensiteitsverhoudingretinale ganglioncelleninverted microscopieexcitatiegolflengtenserumvrij mediumoxidatie reductiecelcultuurvoorbereiding