Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Drug Microinjection with Electrophysiological Recording in a Rat Brain

1.1K weergaven

8 juli 2025

In dit artikel

Samenvatting

Source: Lai, J., et al. Simultaneous electrophysiological recording and micro-injections of inhibitory agents in the rodent brain. J. Vis. Exp. (2015)

This protocol outlines the assembly and use of an injectrode for precise drug delivery into targeted brain regions of an anesthetized rat, followed by monitoring of neuronal activity through recorded electrical signals.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Assembly of the Recording-injection Pipette

  1. Pull an approximately 7 cm long glass capillary (1 mm outer diameter) using a pipette puller.
  2. Break the capillary tip and check the aperture under a light microscope. Confirm that the inner diameter is between 30 µm to 40 µm.
  3. Insert a 7 cm long silver wire into the glass capillary with approximately 1 cm protruding from the non-tapered end of the glass pipette.
  4. Bend the ex....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Micropipette diagram; parts labeled A-F; used for precise liquid measurement in labs.
Figure 1: Schematic representation of the injectrode assembly. A microsyringe (A) is attached to the recording-injection pipette, which consists of a 30 G hypodermic needle (B) adhered to a silver wire (C) inside a glass pipette (D). Regions circled (E-F) highlight ar.......

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Injection pump (UltraMicroPump III)WPI#UMP3
Injection console (Micro4 Controller)WPI#SYS-MICRO4
Hamilton syringeHamliton(80301) 701LT 10 µL SYRSyringes between 5 and 10 μL used
Gel cyanoacrylate adhesiveKrazy GlueKG86648RThe gel form is easier to apply on the shaft of the 30G hypodermic needle
Glass pipettesWPI#TW100F-4Thin wall, 1mm OD, 0.75mm ID with filament pipettes used
720 Needle Pipette PullerKopf720
Silver wireA-M Systems, Inc.782500Bare 0.010"
Agar
Capillary tubes
Hypodermic needle
Chicago Sky Blue (CSB)
γ-aminobutyric acid (GABA)
lidocaine
Atropine drops
Isoflurane
Heating pad
Stereotaxic table
#10 scalpel blade
mineral oil

Tags

Injectrode-assemblagestereotaxische positioneringmicropompsysteemsuperieure colliculusGABA-oplossingminerale olieagarose-afdekkingmonitoring van neuronale activiteit