Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Recording Brain Electrical Activity in Behaving Mice Using Multi-Shank Linear Silicon Probes

1.3K weergaven

⸱

8 juli 2025

In dit artikel

Samenvatting

Source: Sauer, J., et al. Recording Spatially Restricted Oscillations in the Hippocampus of Behaving Mice. J. Vis. Exp. (2018).

This video outlines a protocol for implanting a multi-shank linear silicon probe into the mouse brain to measure local field potentials. The procedure involves securing the probe to a stereotaxic unit, positioning it accurately over the target brain region, inserting it into the brain, and securing it with dental cement. After implantation, the assembly is protected with a casing. Following recovery, the setup allows for recording local field potentials, providing insights into neuronal activity.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparations

  1. Design and build an appropriate insertion tool transiently carrying the silicon probe and the electrode connector during the process of implantation. See Figure 1 for an example custom built insertion tool.
  2. Carefully release the silicon probe and electrode connector from its packaging using ceramic-tipped forceps.
  3. Lift the connector board and securely fix it with a crocodile clamp attached to a stand.
  4. Using ....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Electrophysiology setup with electrode connector, probe shanks, holder; neural signal measurement.
Figure 1: Image of the insertion tool. The silicon probe is attached to an insect pin glued to the base of a crocodile clamp. The shaft of the holder can be inserted in a stereotaxic micro manipulator for implantation.

....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Crocodile clamp with standReichelt ElektronikHALTER ZD-10D
Silicon probeCambridge NeurotechP-series 32
StereoscopeOlympusSZ51
Varnish-insulated copper wireBürklin Elektronik89 F 232
Ground screwsScrews & More GmbH (screwsandmore.de)DIN 84 A2 M1x2
FluxStannol114018
Ceramic-tipped forcepsFine Science Tools11210-60
Paraffine WaxSigma-Aldrich327204
CauterizerFine Science Tools18010-00
Soldering ironKurtz ErsaOIC1300
EthanolCarl Roth9065.1
Pasteur pipettesCarl RothEA65.1
Heat sterilizerFine Science Tools18000-45
Stereotaxic frameDavid KopfModel 1900
Stereotaxic electrode holderDavid KopfModel 1900
IsofluraneAbbvieB506
Oxygen concentratorRespironix1020007
BuprenorphineIndivior UK Limited
Electrical shaverTondeoEco-XS
Heating padThermolux463265/-67
Surgical clampsFine Science Tools18050-28
Hydrogen peroxideSigma-AldrichH1009
Sterile cotton wipesCarl RothEH12.1
DrillProxxonMicromot 230/E
21G injection needleB. Braun4657527
Phosphate buffer/phosphate buffered saline
Stereotaxic atlasElsevier9.78E+12
Surgical scissorsFine Science Tools14094-11
Surgical forcepsFine Science Tools11272-40
27G injection needlesB. Braun4657705
Vaseline
Dental cementSun MedicalSuperBond T&M
CarprofenZoetisRimadyl 50mg/ml
Recording amplifier Intan Technologies C3323
USB acquisition board Intan Technologies C3004
Recording cablesIntan Technologies C3216
Electrical commutator Doric lenses HRJ-OE_FC_12_HARW

Meer artikelen verkennen

Lineaire siliciumsonde met meerdere schachtenstereotaxische frame-implantatieregistratie van lokale veldpotentialenhersenchirurgie bij muizenfixatie met tandcementcraniotomie-blootstellingbevestiging van ankerschroevenbedrading van de connectorplaataanbrengen van beschermende behuizingpostoperatief herstel