Een abonnement op JoVE is vereist om deze inhoud te bekijken. Log in of start vandaag met uw gratis proefperiode.

Methodenartikel

Analyzing Sleep Behavior in Mice through Electroencephalogram and Electromyogram Recordings

3.5K weergaven

⸱

8 juli 2025

In dit artikel

Samenvatting

Source: Oishi, Y., et  al. Polygraphic Recording Procedure for Measuring Sleep in Mice. J. Vis. Exp. (2016).

This video demonstrates a protocol for implanting an electroencephalogram (EEG) and electromyogram (EMG) electrode assembly in an anesthetized mouse. The process involves securing the mouse on a stereotaxic frame, making a midline incision in the skull, drilling holes for the electrodes, and fixing the electrode unit for signal recording. After recovery, the mouse's sleep-wake behavior is analyzed using the recorded signals.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation of Electrodes and Cables for EEG/EMG Recordings

  1. Prepare EEG/EMG recording electrode according to the following procedure.
    Note: The electrode is disposable and can be used only for 1 animal. Plan carefully the wiring configuration for all connectors. Place marks on the connectors for the correct orientation.
    1. Solder each pin of a 4-pin header to a 2-cm stainless steel wire. In brief, hold one end of the wire to the pin, ....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
4-pin headerHiroseA3B-4PA-2DSA(71)
AmpicillinMeiji SeikaN/A
Analog-to-digital converterContecAD16-16U(PCIEV)
Carbide cutterMinitorB1055
Crimp housingHiroseDF11-4DS-2C
Crimp socketHiroseDF11-30SC
Dental cement (Toughron Rebase)Miki Chemical ProductN/A
Epoxy adhesiveKonishi#16351
FFC/FPC connectorHonda Tsushin KogyoFFC-10BMEP1(B)
Flat cableHitachi Cable20528-ST LF
Instant glue (Aron Alpha A)ToagoseiN/A
MeloxicamBoehringer IngelheimN/A
PentobarbitalKyoritsu SeiyakuN/A
Signal amplifierBiotexN/A
Sleep recording chamberAPLN/A
SleepSign softwareKissei ComtecN/Afor EEG/EMG recording/analysis
Slip ringBiotexN/A
Stainless steel screwYamazakiN/Aφ1.0×2.0
Stainless steel wireCooner WireAS633

Meer artikelen verkennen

EEG-EMG-registratieslaapanalyse bij muizenstereotactisch frameelektrodenimplantatiesignaalversterkinganalyse van slaapfasenelektromyogram-elektrodenelektro-encefalogram-elektrodengeluidsdichte kamerAD-converter