Source: Meng, Y. et al., In Vitro Characterization of the Electrophysiological Properties of Colonic Afferent Fibers in Rats. J. Vis. Exp. (2017)

This video demonstrates a method to record the activity of colonic afferent nerves in an ex-vivo rat colon, cannulated at both ends and infused with saline to increase intraluminal pressure. As pressure increases, the nerve signal rises, indicating its stimulation.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation of Perfusion Solution and Test Compounds

  1. Prepare 5 L of Krebs solution: 113 mM sodium chloride, NaCl, 5.9 mM potassium chloride, KCl, 1.2 mM Di-hydrogen sodium phosphate, NaH2PO4, 1.2 mM magnesium sulfate, MgSO4, 25 mM sodium bicarbonate, NaHCO3, 1.2 mM calcium chloride, CaCl2, and 11.5 mM glucose. Saturate the solution with a 95% O2 + 5% CO2 gas mixture. Pre-cool ~500 mL of oxyg....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Neural activity diagram with pelvic ganglion; graphs show pressure, firing rate, neurogram data.
Figure 1. Electrophysiological Recording of Rat Colonic Afferent Nerves In Vitro. A. A schematic illustration of the ex vivo "tube" colon preparation of the rat. The colorectum, with the attached PG, is superfused in the recording chamber .......

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
Sodium PentobarbitalShanghai Westang Bio-TechB558
CapsaicinSigmaM2028
Electrode pullerMicroData Instrument IncPMP107
Neurolog System (Bioamplifier)Digitimer, LtdNeurolog System
A/D converterCambridge Electronic DesignMicro1401
Data processing softwareCambridge Electronic DesignSpike2 version 6
Silver wireWorld Precision InstrumentsEP12
Glass tubesWorld Precision Instruments1B150-4
Electrode holderWorld Precision InstrumentsMEH3SBW
Heating bathGrantGR150
Dissecting microscopeLeicaZoom2000
Dissecting microscopeWorld Precision InstrumentsPZMIII-BS
Cigarette lighteranyNA
Surgical toolsWorld Precision InstrumentsNA
Insect pinshome-made from 0.1 mm stainless steel wireNA
Three way manipulatorWorld Precision InstrumentsKITF-R
RatsAnyNAAny strain/sex can be used.