Source: Soukupová, M., et al. Microdialysis of Excitatory Amino Acids During EEG Recordings in Freely Moving Rats. J. Vis. Exp. (2018)

This video demonstrates electroencephalographic (EEG) recording of epileptic seizures in epilepsy-induced rats. A rat with electrodes implanted in the ventral hippocampus is connected to the EEG recording system and placed in a plexiglass chamber. The rat is allowed to move freely while the brain activity is recorded to monitor the occurrence of seizures.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Assembly of the Microdialysis Probe-electrode Device

  1. Use a 3-channel two-twisted electrode (with at least a 20 mm cut length of the registering electrode and a 10 cm long grounding electrode) and couple it to a guide cannula to prepare the device. See examples of 3-channel electrodes and guide cannula for dialysis in Figure 1A-1B.
  2. Remove (Figure 1C) and insert (Figure 1D) the metal guide cannula into the d....

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Resultaten

Step-by-step probe-electrode assembly; diagrams show micrometer measurements and resin application.
Figure 1. Step-by-step preparation of the device to be implanted. (A) 3-channel electrode with 10 cm long grounding electrode in its protective sleeve on the left and guide cannula for microdialysis on the right needed to assemble the device. (B). The ba.......

Toegang beperkt. Log in of start een proefperiode om deze inhoud te bekijken.

Openbaarmakingen

No conflicts of interest declared.

Materialen

Lijst van materialen gebruikt in dit artikel
NaamBedrijfCatalogusnummerOpmerkingen
3-channel two-twisted electrodeInvivo1, Plastic One, Roanoke, Virginia, USAMS333/3-B/SPCMaterial
guide cannulaAgn Tho's, Lindigö, SwedenMAB 4.15.ICMaterial
Resin KK2 PlastikElettra Sport, Lecco, ItalyKK2Material
Super Attack gel LoctiteHenkel Italia Srl, Milano, Italy 2047420_71941Material
Imalgene-KetamineMerial, Toulouse, France221300288 (AIC)Solution
XylazineSigma, Milano, ItalyX1251Material
Isoflurane-VetMerial, Toulouse, France103120022 (AIC)Solution
Altadol 50 mg/ ml - tramadolFormevet, Milano, Italy103703017 (AIC)Solution
Gentalyn 0.1% crm - gentamycineMSD Italia, Roma, Italy20891077 (AIC)Material
simplex rapid dental cementKemdent, Associated Dental Products Ltd, Swindon, United KingdomACR811Material
GlasIonomer CX-Plus CementShofu, Kyoto, JapanPN1167Material
probe clip holderAgn Tho's, Lindigö, Swedenp/n 100 5001Equipment
Histoacryl® Blue Topical Skin AdhesiveTissueSeal, Ann Arbor, Michigan, USATS1050044FPMaterial
Valium 10 mg/2 ml - diazepamRoche, Monza, Italy019995063 (AIC)Material
1 mL syringe with 25G needleVetrotecnica, Padova, Italy11.3500.05Material
rat flexible feeding needle 17GAgn Tho's, Lindigö Sweden7206Material
Grass Technology apparatusGrass Technologies, Natus Neurology Incorporated, Pleasanton, California, USAM665G08Equipment (AS40 amplifier, head box, interconnecting cables, telefactor model RPSA S40)
modular data acquisition and analysis system MP150Biopac, Goleta, California, USAMP150WSWEquipment
digital video surveillance systemAverMedia Technologies, Fremont, California, USAV4.7.0041FDEquipment

Trefwoorden

ventrale hippocampusEEG registratiesysteemplexiglas kamerexcitatoire neurotransmittersinhibitoire neurotransmittersregistratie van elektrische signalenversterkeropstelling