All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
- Run tastant panel
- Use suction to remove liquid from over the geniculate. Optionally place an absorbent point to help mitigate seepage and aid in microscope navigation.
- Place the animal on an absorbent pad under the microscope. Locate the geniculate ganglion: useful landmarks include the hole left in the bulla, the hole in the temporal bone, and the seventh nerve. Using the FITC/GFP (Fluorescein Isothiocyanate/ green fluorescent protein) filter on the epifluorescence scope, check for individual GCaMP-expressing geniculate ganglion neurons. A 10x objective (working distance of 10 mm) will provide sufficient resolution to track the activity of individual cells, but a 20x objective (working distance of 12 mm) can also be used.
- Place dispensing needle for tastant line firmly in animal's mouth. Place a Petri dish below the animal's mouth to catch fluid.
- Ensure that the camera is viewing the microscope's field of view. Synchronize the start of the video recording with the start of the tastant presentation.
- During recording, watch the live feed for responses, drift, and seepage.