Anion-Exchange Chromatography-Based Protein Purification: A Separation Technique to Isolate a Protein of Interest From Dialyzed Bacterial Lysate Based on Net Charge

0 weergaven2:59 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

For anion-exchange chromatography separation of a protein of interest from a dialyzed bacterial protein lysate, add a binding buffer to reduce the lysate viscosity and prevent it from clogging the chromatographic column.

The chelating agents in the buffer bind divalent cations, inhibiting protease activity and preventing protein degradation. Additionally, the buffer with pH above the target protein's isoelectric point, pI, the pH at which the protein has no net charge, causes the excess negatively charged hydroxyl ions to neutralize the protein's positively charged amine groups, rendering protein's surface negatively charged.

Assemble the anion-exchange chromatography column containing cross-linked, agarose-based stationary phase with positively charged quaternary amine groups. Add the binding buffer to prepare the column for maximum protein interaction during sample loading. Load the diluted bacterial lysate.

The negatively charged target proteins bind more tightly to the positively charged groups in the column than less negatively charged proteins.

Run the binding buffer to remove unbound positively charged proteins from the column. Pass an elution buffer through the column, gradually increasing the salt concentration. At low salt concentrations, negative ions compete with weakly bound proteins to bind to the column, causing their elution.

Subsequently, the high salt concentration buffer displaces tightly bound proteins of interest with a longer retention time, eluting the target proteins. The collected target proteins can be used for further analysis.

Start the FPLC with general maintenance. Connect column buffers AIEX-A and AIEX-B to buffer valves, and the anion-exchange resin-containing column to the column ports of the FPLC. Adjust the general chromatographic parameters accordingly.

Start the AIEX program in the FPLC software and choose the equilibration volume for buffer A. Subsequently, load the sample onto the column, and elute the proteins with a linear gradient from 0% to 100% high-salt buffer. Collect 2-milliliter fractions during elution.

Analyze the eluted fractions after finishing the run.

08:01

LERLIC-MS / MS Gedetailleerde karakterisering en kwantificering van glutamine en asparagine Deamidatie in Shotgun Proteomics

Gerelateerde video's

0 Bekeken

08:44

Isolatie van F1-ATPase van de parasitaire Protist Trypanosoma brucei

Gerelateerde video's

0 Bekeken

10:41

Ionenwisselingschromatografie (IEX) gekoppeld aan meerdere hoek lichtverstrooiing (MALS) voor eiwit scheiding en karakterisering

Gerelateerde video's

0 Bekeken

10:21

Geautomatiseerde hydrofobe interactiechromatografie Kolomselectieopties voor gebruik in Protein Purification

Gerelateerde video's

0 Bekeken

03:28

Selective Purification of a Bacterial Protein by Negative Ion-Exchange Chromatography

Gerelateerde video's

0 Bekeken

02:54

An Affinity Chromatography Technique for the Purification of a Recombinant Bacterial Protein

Gerelateerde video's

0 Bekeken

03:54

Nickel Affinity Chromatography-Based Protein Purification: A Technique to Purify Polyhistidine-Tagged Recombinant Proteins from Bacterial Cell Lysate

Gerelateerde video's

0 Bekeken

03:33

Cation Exchange Chromatography: A Technique to Isolate Target Recombinant Protein from Insect Cell Lysate Based on Net Surface Charge

Gerelateerde video's

0 Bekeken

14:25

Methode voor het efficiënt uiteinde en zuivering van de Chemoreceptor-Ligand bindend domein

Gerelateerde video's

0 Bekeken

07:19

Affiniteitszuivering van een 6X-His-gelabeld eiwit met behulp van een snel eiwitvloeistofchromatografiesysteem

Gerelateerde video's

0 Bekeken

Laatst bijgewerkt: 15 augustus 2026