This protocol has been approved by the Fox Chase Cancer Center Institutional Animal Care and Use Committee and by the Laboratory Animal Facility, and found to be in accordance with institutional guidelines for humane treatment of animals. 1. Preliminary Preparation Preparation of catheter: Prepare a catheter from a short length of polyethylene tubing, modified to form a thinned, blunted end (Figure 3A). Make multiple catheters in advance and save indefinitely. Light a Bunsen burner, and adjust to establish a low steady flame. Hold tubing close to flame to soften polyethylene. When tubing begins to melt, slowly pull apart the two ends to create a thinned section of tubing, approximately 0.25 mm OD. Cut a beveled end approximately 0.75 cm along thin section. This ensures enough tubing to be secured in artery, without creating an overly long catheter. NOTE: A long thin end on the catheter has a propensity to clog. An overly long end may also hold enough liquid to significantly change the catheter’s liquid volume capacity. Blunt the beveled end by passing quickly through the flame — when properly heated, the end becomes slightly rounded and enlarged. The tip hooks back slightly, which helps anchor the tubing while inserting into the artery. Cut the tubing 6.0 cm from the point where it begins to thin. This makes a very manageable catheter, that is long enough to thread through to exit from the neck and to hold and work with comfortably, but short enough to prevent the mouse from gnawing on excess tubing or requiring too much extra infusion volume to clear initial saline. Prepare a syringe of approximately 0.2 ml heparin solution, topped with a blunted needle. Insert needle into the wide end of the catheter (Figure 3B). Fill catheter with heparin, being careful to ensure that there are no bubbles in the tubing. Set the heparin syringe and catheter aside on a sterile area. Sterilize catheters by gamma irradiation, by placing catheter(s) in a petri dish, and exposing to 20 Gy of gamma irradiation. If you do not have access to an gamma radiation source, check with your animal facility to investigate other means of sterilization, such as gas- or chemical-sterilization. Do not autoclave, as polyethylene cannot be heat sterilized. Creation of a saline lead (Figure 3B). Prepare a second syringe of approximately 0.5 ml sterile saline, being careful to ensure a bubble-free line. Cut a second piece of tubing, approximately 15 cm, and slip onto the blunted syringe needle. Attach a connector port to the free end of the tubing. Test that flow of saline is unobstructed by smoothly advancing a small volume of saline through the lead. Use this saline lead after catheter insertion, to check the flow through the catheter, and to flush the line of blood. Set the saline syringe aside on a sterile area. Prior to surgery, sterilize equipment by autoclaving, or alternatively by gas sterilization or glass bead sterilization. Prepare sterile surgical area. Wipe bench and microscope surfaces with disinfectant such as 70% ethanol or chlorine dioxide. Cover bench and microscope base with a clean disposable, absorbent pad. Prepare a surgical board by covering with two layers of clean, absorbent paper, securely attached with adhesive tape. Lay out all surgical supplies (as cataloged in Materials List) so that they are readily accessible. Cut three lengths of sterile suture, 8 cm each, and set aside with other supplies. Place a port where it will be easily available (Figure 3B). 2. Surgery Preparation of the animal Anesthetize mouse by exposure to 2-3% isoflurane in anesthesia chamber connected to precision vaporizer. Withdraw mouse from the chamber, and shave hair from the mouse’s neck / upper torso, and below the right ear (site of catheter exit). Administer veterinary petrolatum ophthalmic ointment to eyes to prevent dryness while under anesthesia. Ensure the animal does not awaken during surgical preparations by allowing mouse sufficient time in inhalation chamber before prep (at least two min), or by administering isoflurane to mouse by means of a nose cone during prep. Return mouse to anesthesia chamber. When mouse is sufficiently inert, move to sterile surgical area, place anesthesia nose cone over the mouse’s nose and mouth, and divert the flow of isoflurane to nose cone. Confirm proper anesthetization by pinching paw with forceps; when the mouse shows no reaction, proceed to next step. Position the mouse on its back, with the head facing toward the investigator. Secure the ears, fore-paws and hind-paws to surgical board with adhesive tape or other restraining device to keep the mouse steady. Clean the incision area with povidone-iodine and 70% ethanol. Isolation of carotid artery Make a 1 cm longitudinal cut slightly to the right of the midline of the neck. Use forceps to separate fat and muscle to expose the trachea (Figure 4A). Locate the carotid artery running parallel to the trachea (Figure 4B). Carefully use forceps to separate fascia overlying the artery (Figure 4C). Lightly pull the vagus nerve aside from the carotid, and insert forceps into the space between. Gently open forceps to create a gap in the fascia, and carefully pull away the nerve from the artery, from the fork in the artery near the larynx (anterior end), up (posterior) as far as possible (at least 3 mm) (Figure 4D). Clear away any remaining fascia until the artery is well isolated (Figure 4E). Add a drop of saline to the surgery area occasionally to keep tissue moist, and thus less brittle and less prone to tearing randomly. Suture placement and artery preparation for catheter insertion (Figures 4, 5). Use forceps to draw a silk suture thread under the artery. Tie a secure knot to close off the artery as far toward the anterior as possible (Figure 4F). Draw a second thread under the artery. Tie a retractable knot to temporarily close off the artery as far toward the posterior as possible (Figure 4F). Draw a third thread under the artery. Tie a very loose knot between the first two sutures, to be used to quickly secure the catheter after placement (Figure 4G). Hold ends of all sutures out of the way by wetting them with a bit of 70% ethanol. Catheter insertion With the suture, grab the lower knot to pull the artery slightly taut. Nick the artery above, but very close to, the anterior suture (Figure 4H). Be careful not to cut too deeply, but check the slit to make sure the opening is unobstructed. Remove heparin-filled catheter from syringe needle, trying to avoid creating large pockets of air at either end. Manipulate the catheter to position bevel at a comfortable angle, generally downward, and slightly to the right (for right-handers). While holding on to the suture to keep the artery remaining slightly taut, gently insert catheter into slit (Figure 4I). Use the forceps to hold the anterior suture and pull the artery down over catheter (pushing up excessively with the catheter may cause the beveled end to puncture the artery). Carefully release the catheter and anterior suture. Securing of catheter and initiation of blood flow (Figures 4J, 5B). Secure the catheter by tightening the knot of the middle suture, close to the entrance of the catheter into the artery. Make a tight triple knot, but be sure not to pull so tight as to obstruct flow through the catheter. Further secure the catheter by tying it down with the anterior suture, below the entrance to the artery. Attach the saline lead to the catheter by means of the connector plug, again trying to avoid introducing air bubbles into the line. Grasp the ends of the posterior suture and gently pull to release the knot. Maneuver the suture down the artery, over the end of the catheter (do not remove the thread). Blood should flow into the catheter; if there is no blood flow, gently wiggle catheter to attempt to remove the constriction. When flow appears unobstructed, use the last thread (from the posterior suture) to tie an additional knot, slightly above the middle suture. Temporary sealing of catheter. Flush the catheter of blood, then use a hemostat to clamp the end of the catheter close to the connector plug. Remove the connector and replace it with the port plug to seal off the end of the catheter, and remove the hemostat. Repositioning catheter to exit from back of neck. With forceps in each hand, use one pair of forceps to hold on to the catheter just below the anterior suture, and with the other, press a kink into the catheter so it will easily bend to the side. Repeat to create a second kink. This allows the free end of the catheter to be pulled toward the back of the mouse’s head, without forcing the tip of the catheter to turn laterally against the wall of the artery. Turn the mouse onto its (left) side, keeping the nose cone positioned over the mouth and nose, and clean the incision area with 70% ethanol and povidone-iodine. Make a small incision (approximately 4 mm) below and behind the right ear. Use forceps to hold the open flap of skin, while working the blunt hollow probe under skin to create a channel through the cheek, to the cavity at the neck. It is advisable to bring the probe around the salivary gland, instead of trying to go between the gland and the skin. Use forceps to carefully free a space for the probe to exit. Thread port plug/catheter through probe to exit in neck. Do not pull too hard; be sure the catheter is not crushing or constricting blood vessels or organs. Closure and recovery. Administer topical analgesic (e.g. bupivacaine) to the shoulder incision, and cover the wound with water-proof, surgical adhesive tape. Apply a second piece of adhesive tape to further secure the catheter. Administer topical analgesic to chest incision, and close wound with silk or staples. Remove mouse from anesthesia, and allow animal to recover in a clean, warmed space (place cage on top of a heating pad or under a heat lamp), for at least 30 min. 3. Infusion Prepare aliquots of 5 mg/ml solution of paclitaxel / methanol. Measure 50 mg of paclitaxel into a 15 ml centrifuge tube. Add 10 ml of sterile methanol. Cap tube. Rotate by hand or on a rotating shaker at room temperature until powder is dissolved. Aliquot 500 µl of solution into 20 small, freezer safe tubes, and store at -20 °C. Thaw individual aliquot at room temperature or in 37 °C water bath, immediately before infusion. Prepare the infusion pump (Figure 6). Cut a long length of polyethylene tubing of approximately 40 cm. Attach a blunted needle to one end, and a connector port to the other. Draw up drug into a syringe with a known inner-diameter (most programmable pumps will require the diameter of the syringe barrel, in order to calculate the speed of the pump arm). Attach the needle to the syringe and load the drug through the needle and tubing. Situate the syringe into the pump according to the manufacturer’s directions. Prime the pump so that the drug is flowing smoothly out the connector plug, and it is ready for infusion. Attach mouse to pump. Hold the mouse steady and use the hemostat to clamp catheter, close to the port plug. Remove plug and replace with the connector attached to the syringe and tubing. NOTE: Blood may start to flow back through tubing. Quickly administer a fast pump to clear the volume of the catheter (calculated empirically through observing the volume of 6 cm of tubing), then immediately switch to the desired infusion rate. Continue Paclitaxel infusion for three hour time course. Monitor tubing occasionally to check for leaks at junctions as this is often a sign of a blockage in the flow to the mouse. Watch the mouse for expected or unexpected reactions to infusion (lethargy or hyperactivity, signs of discomfort). Depending on the length and nature of the infusion, the mouse might not eat or drink, but be sure to provide access to food and water according to the institution’s established policy. Be aware of the potential for dehydrating the mouse through collection of large quantities of blood. Continue to keep the cage warm with a heating pad or lamp, unless the mouse appears to desire to stay away from the heat. If animal is not euthanized within several hr after surgery, implement plan for post-surgical treatment of animal, including sterile housing conditions and treatment for post-surgical pain. Keep a close watch on the mouse, especially in the first few min, to ensure it does not pull out the tubing through hyperactivity, or irritation from tubing (which may be a sign of a poor insertion). If the mouse is not over-active, constant monitoring may not be necessary, but check the mouse routinely to be sure the animal does not get tangled in the tubing. Harness and tether system are available commercially, but their use is beyond the scope of this protocol. Collection of samples. Collect blood samples at regular intervals by submandibular or retro-orbital bleeds (If your protocol does not make use of mammary tumor models, consider collection of blood via a jugular catheter inserted at the same time as the carotid catheter). Be careful not to pull on the infusion line. If collecting by retro-orbital bleeds, lightly anesthetize the mouse with an inhalational anesthetic (e.g. methoxyflurane) so one need not grab by the scruff to secure the mouse. Spin blood in hemocrit centrifuge to separate blood cells from plasma. Use a file or diamond-tip pen to score tube at face of phase separation. Break tube and collect plasma only, into small, freezer-safe tube. Store at -80 °C until analysis. NOTE: If a hemocrit centrifuge is not available, transfer blood sample into micro-centrifuge tube, and spin in a micro-centrifuge at high speed to separate blood cells from plasma. Collect plasma into a second tube, and store at -80 °C. Euthanize mouse by CO2 asphyxiation. Collect tissue (about 20 – 50 mg) from organs of interest and flash freeze in liquid nitrogen. Store at -80 °C until analysis. 4. Sample Analysis NOTE: All samples for this protocol were analyzed through an outside laboratory by liquid chromatography-tandem mass spectrometry (LC-MS/MS), who calculated the paclitaxel concentrations as follows: Extract paclitaxel from samples. Homogenize tissue sample in 0.1% acetic acid, 50% methanol prior to extraction. Extract paclitaxel by liquid/liquid extraction, using methyl tert-butyl ether (MTBE) fortified with an internal analogue (docetaxel) standard. Remove MTBE and dry samples. Resuspend in 50% acetonitrile, 0.1% acetic acid solution. Prepare calibration standards. Add a known concentration of paclitaxel to appropriate C57BL/6 matrix to obtain a final range of standards (from 1 to 20,000 ng/ml for plasma samples, from 0.1 to 5,000 ng/ml for tissue samples). Extract standards in duplicate, using the same method as for the study samples above. Measure paclitaxel peak in samples by HPLC/MS/MS utilizing electrospray ionization. Calculate concentration using the area ratio of paclitaxel to internal standard. Use calibration standards to create a standard curve, and interpolated study samples by fit on the curve. Normalize concentration of study samples by the starting weight of sample before homogenization.