Pin Fixation

Pin fixation is a method of stabilizing fractured or surgically manipulated bone by placing rigid pins across or alongside the affected region, helping maintain alignment during healing. Depending on the design and placement, pins transfer mechanical loads between bone fragments and an external frame or internal support, while resisting displacement from bending, rotation, and axial forces. In bioengineering, pin fixation provides a practical model for studying bone-implant interactions, fixation stability, mechanical loading, and tissue regeneration. Its effectiveness depends on factors such as pin geometry, material properties, insertion position, bone quality, and the balance between mechanical stability and biological healing.

Pin Fixation - Related Videos

Education

JoVE Core - Mechanical Engineering

Euler's Formula for Pin-Ended Columns

0 Views •

2024

In structural engineering, the stability of columns under compressive axial loads is a critical consideration, described as buckling. A typical example involves a column PQ, which is pin-connected at both ends and subjected to a centric axial load F applied at one end, with a reaction force of F' = -F at the other end. Here, it is crucial to understand that when an applied load exceeds the critical load, buckling occurs as the system becomes unstable. To calculate the critical load, envision...

Research

JoVE Journal - Neuroscience
Free Sample

Whole Animal Perfusion Fixation for Rodents

0 Views •

Cited by 531 •

2012

Here we describe a low-cost, rapid, controlled and uniform fixation procedure using 4% paraformaldehyde perfused via the vascular system: through the heart of the rat to obtain the best possible preservation of the brain.

Fixation and Sectioning

0 Views •

2023

Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens. The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...

Transverse Fracture of the Mouse Femur with Stabilizing Pin

0 Views •

Cited by 3 •

2021

This protocol describes a method to perform fractures on adult mice and monitor the healing process.

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models

0 Views •

Cited by 19 •

2014

One constraint of preclinical research in the field of bone repair is the lack of experimental control over the local mechanical environment within a healing bone lesion. We report the design and use of an external fixator for bone repair with the ability to change fixator stiffness in vivo.

View All Results

FAQs

Related Topics