-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

PL

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

pl_PL

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Medicine
Nieinwazyjna ocena nieprawidłowości serca w eksperymentalnym autoimmunologicznym zapaleniu mięśni...
Nieinwazyjna ocena nieprawidłowości serca w eksperymentalnym autoimmunologicznym zapaleniu mięśni...
JoVE Journal
Medicine
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Medicine
Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse

Nieinwazyjna ocena nieprawidłowości serca w eksperymentalnym autoimmunologicznym zapaleniu mięśnia sercowego za pomocą obrazowania za pomocą rezonansu magnetycznego u myszy

Full Text
10,486 Views
12:24 min
June 20, 2014

DOI: 10.3791/51654-v

Chandirasegaran Massilamany*1, Vahid Khalilzad-Sharghi*2, Arunakumar Gangaplara1, David Steffen1, Shadi F. Othman2, Jay Reddy1

1School of Veterinary Medicine and Biomedical Sciences,University of Nebraska-Lincoln, 2Department of Biological Systems Engineering,University of Nebraska-Lincoln

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study demonstrates the successful establishment of magnetic resonance microscopy imaging as a non-invasive tool to assess cardiac abnormalities in mice affected by autoimmune myocarditis. The technique can be used to monitor disease progression in live animals.

Key Study Components

Area of Science

  • Neuroscience
  • Cardiology
  • Imaging Techniques

Background

  • Autoimmune myocarditis is a condition that affects cardiac function.
  • Magnetic resonance microscopy imaging provides a non-invasive method for assessment.
  • Monitoring disease progression is crucial for understanding treatment efficacy.
  • Live imaging allows for real-time analysis of cardiac parameters.

Purpose of Study

  • To ascertain cardiac functional abnormalities in live mice.
  • To utilize magnetic resonance microscopy for imaging hearts affected by inflammatory heart disease.
  • To calculate end diastolic volume and ejection fraction in affected mice.

Methods Used

  • Induction of myocarditis in mice.
  • Preparation of animals for imaging.
  • Placement of mice in a magnetic resonance microscopy system.
  • Analysis of cardiac functional parameters using segment software.

Main Results

  • Successful imaging of cardiac abnormalities in live mice.
  • Quantitative assessment of end diastolic volume and ejection fraction.
  • Demonstration of the technique's effectiveness in monitoring disease progression.
  • Validation of non-invasive imaging for cardiac assessment.

Conclusions

  • Magnetic resonance microscopy is a valuable tool for studying cardiac abnormalities.
  • This method allows for real-time monitoring of autoimmune myocarditis.
  • Further research can build on these findings to improve treatment strategies.

Frequently Asked Questions

What is autoimmune myocarditis?
Autoimmune myocarditis is an inflammatory condition of the heart muscle caused by the immune system attacking the heart.
How does magnetic resonance microscopy work?
Magnetic resonance microscopy uses magnetic fields and radio waves to create detailed images of the heart's structure and function.
What are end diastolic volume and ejection fraction?
End diastolic volume is the amount of blood in the heart at the end of filling, while ejection fraction measures the percentage of blood pumped out with each heartbeat.
Why is non-invasive imaging important?
Non-invasive imaging allows researchers to study live animals without causing harm, enabling better monitoring of disease progression.
What are the implications of this study?
The findings suggest that magnetic resonance microscopy can be used to monitor cardiac diseases, potentially leading to improved treatment approaches.

To badanie pokazuje udane wprowadzenie obrazowania metodą rezonansu magnetycznego jako nieinwazyjnego narzędzia do oceny nieprawidłowości serca u myszy dotkniętych autoimmunologicznym zapaleniem mięśnia sercowego. Dane wskazują, że technika ta może być stosowana do monitorowania postępu choroby u żywych zwierząt.

Ogólnym celem tej procedury jest ustalenie nieprawidłowości czynnościowych serca poprzez obrazowanie serca u żywych zwierząt dotkniętych chorobą zapalną serca. Osiąga się to poprzez najpierw wywołanie choroby, na przykład zapalenia mięśnia sercowego. Drugim krokiem jest przygotowanie zwierzęcia do obrazowania za pomocą rezonansu magnetycznego i umieszczenie go w uchwycie na zwierzę.

Następnie mysz jest umieszczana wewnątrz magnesu w celu uzyskania obrazów serca. Ostatnim krokiem jest analiza parametrów czynnościowych serca za pomocą oprogramowania segmentowego. Ostatecznie technika ta służy do obliczania końcowej objętości rozkurczowej i frakcji wyrzutowej u myszy dotkniętych autoimmunologicznym zapaleniem mięśnia sercowego.

View the full transcript and gain access to thousands of scientific videos

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Słowa kluczowe: mikroskopia rezonansu magnetycznego zapalenie mięśnia sercowego eksperymentalne autoimmunologiczne zapalenie mięśnia sercowego ciężki łańcuch miozyny serca grubość ściany komory średnica komory obrazowanie nieinwazyjne

Related Videos

Echokardiografia o wysokiej rozdzielczości o wysokiej częstotliwości: pierwsze dowody na nieinwazyjny powtarzający się pomiar napięcia mięśnia sercowego, kurczliwości i niedomykalności zastawki mitralnej w mysim sercu z niedokrwieniem

11:50

Echokardiografia o wysokiej rozdzielczości o wysokiej częstotliwości: pierwsze dowody na nieinwazyjny powtarzający się pomiar napięcia mięśnia sercowego, kurczliwości i niedomykalności zastawki mitralnej w mysim sercu z niedokrwieniem

Related Videos

24.8K Views

Ocena czynności serca i morfologii mięśnia sercowego za pomocą rezonansu magnetycznego małych zwierząt z odwróconym odzysku z odwróconej szafki (SALLI) u szczurów

08:41

Ocena czynności serca i morfologii mięśnia sercowego za pomocą rezonansu magnetycznego małych zwierząt z odwróconym odzysku z odwróconej szafki (SALLI) u szczurów

Related Videos

13.2K Views

MRI i PET w mysich modelach zawału mięśnia sercowego

10:46

MRI i PET w mysich modelach zawału mięśnia sercowego

Related Videos

12.5K Views

In vivo (in vivo) Ilościowa ocena struktury, funkcji, perfuzji i żywotności mięśnia sercowego za pomocą mikrotomografii komputerowej serca

08:13

In vivo (in vivo) Ilościowa ocena struktury, funkcji, perfuzji i żywotności mięśnia sercowego za pomocą mikrotomografii komputerowej serca

Related Videos

20.3K Views

Ocena zmian morfologicznych i czynnościowych serca w mysim modelu poprzecznego zwężenia aorty za pomocą obrazowania echokardiograficznego

09:05

Ocena zmian morfologicznych i czynnościowych serca w mysim modelu poprzecznego zwężenia aorty za pomocą obrazowania echokardiograficznego

Related Videos

19.2K Views

Mysi model zawału mięśnia sercowego z wykorzystaniem trwałego podwiązania lewej przedniej zstępującej tętnicy wieńcowej

08:38

Mysi model zawału mięśnia sercowego z wykorzystaniem trwałego podwiązania lewej przedniej zstępującej tętnicy wieńcowej

Related Videos

29.8K Views

Kwantyfikacja funkcji lewej komory serca myszy, napięcia mięśnia sercowego i sił hemodynamicznych za pomocą rezonansu magnetycznego układu sercowo-naczyniowego

11:13

Kwantyfikacja funkcji lewej komory serca myszy, napięcia mięśnia sercowego i sił hemodynamicznych za pomocą rezonansu magnetycznego układu sercowo-naczyniowego

Related Videos

7.4K Views

Indukcja zawału mięśnia sercowego i uszkodzenia niedokrwienno-reperfuzyjnego mięśnia sercowego u myszy

08:28

Indukcja zawału mięśnia sercowego i uszkodzenia niedokrwienno-reperfuzyjnego mięśnia sercowego u myszy

Related Videos

8.6K Views

Dynamiczne oceny rezerwy przepływu wieńcowego po reperfuzji niedokrwiennej mięśnia sercowego u myszy

05:07

Dynamiczne oceny rezerwy przepływu wieńcowego po reperfuzji niedokrwiennej mięśnia sercowego u myszy

Related Videos

2.1K Views

Ocena obciążenia mięśnia sercowego pochodząca z rezonansu magnetycznego przy użyciu śledzenia cech

07:21

Ocena obciążenia mięśnia sercowego pochodząca z rezonansu magnetycznego przy użyciu śledzenia cech

Related Videos

14.9K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code