$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
1. Method
1.1 Apparatus
The successive alleys apparatus consists of four successive linearly connected alleys of putatively increasing anxiogenic character and is made of painted wood (see Figure 1 and, for comparison, Figure 2 of a plus-maze). Details are shown in Table 1:
| Alley | Length | Width | Wall height | Color |
| 1 | 25.0 | 8.5 | 25.0 | Black |
| 2 | 25.0 | 8.5 | 5.0 | Grey |
| 3 | 25.0 | 3.5 | 0.8 | White |
| 4 | 25.0 | 1.2 | 0.2 | White |
Table 1. Construction details for the successive alleys apparatus. All dimensions are in cm.
The apparatus is elevated approximately 50 cm by clamping the back-extended floor of alley 1 to a laboratory bench, shelf or other support. The open end of alley 1 should be at least 10 cm away from the support to prevent mice trying to climb on to it. Provide adequate and ample padding under the alleys in case a mouse falls off.
The rationale for the different wall heights was: those of alley 1 need to be high to maximize its non-anxiogenic properties. Also high walls create a darker environment as long as the laboratory light source is not immediately overhead. The walls of alley 2 were judged from experience to appear less safe than alley 1 to mice, but to still provide some degree of protection. Alleys 3 and 4 had just enough height to maximize anxiety but still provide a grip if the mouse was in danger of falling off. In practice falls are rare, and no more frequent than on the plus-maze.
The apparatus should be handled carefully as the narrow Alley 4 is particularly susceptible to damage. If securely fastened, the apparatus should not vibrate as the mouse moves over it. To minimize both of these potential problems, the apparatus could be given a strengthening extra "spine" spanning its length under the floor. A successive alleys apparatus for rats can also be made. Details are shown in Table 2:
| Alley | Length | Width | Wall height | Color |
| 1 | 45.0 | 9.0 | 29.0 | Black |
| 2 | 45.0 | 9.0 | 2.5 | Grey |
| 3 | 45.0 | 6.7 | 0.5 | White |
| 4 | 45.0 | 3.5 | 0.3 | White |
Table 2. Construction details for the successive alleys apparatus for rats. All dimensions are in cm.
1.2 Procedure
* Bring the mice to the experimental room 5-20 min before testing to ensure that they are adapted to the room and are at a moderate level of arousal.
* As with all experiments where animals are tested once for spontaneous behavior on a novel apparatus, it is good practice for the alleys to be first given a mouse odor; place non-experimental mice on the apparatus for a few minutes, then clean the apparatus as during the main experiment. The objective is to ensure a slight but uniform background mouse odor, on the basis that it is impossible to totally remove animal odor (let alone prove that this has been achieved).
* Place a mouse at the closed end of alley 1 facing the wall. Start timers 1) for the overall length of the test + latency to enter arms, and 2) time spent in alley 1. When the mouse places all 4 feet on to the next alley it is considered to have entered it. Record total time spent in each alley (all four feet) and the number of entries (both forward and backward). Record the number of faecal boli and whether any urination has occurred.
* Test duration: 5 min. (This is the normal time; if you know or suspect that the animals you are testing will not be very anxious, shortening the test duration to 3 min may be advantageous. Note what time you do use).
* A combined event counter/timer is invaluable for this work as well as for timing the plus-maze. We have a battery-powered portable one with four buttons, each associated with an event counter and a timer (1/10 s), built in the Psychology department. Pressing button 1 registers an event (entry into alley 1) and starts a timer. Releasing the button stops the timer. Pressing button 2 registers an alley 2 entry and starts alley 2 timer, etc. However, one must subtract one entry from the total number of entries registered on alley 1 as the first entry was initiated by the experimenter, not the mouse.
* To summarize; for each alley record: the latency to enter it (apart from alley 1 of course), the number of entries into it and the total time spent there.
* If a mouse falls off, stop the clock and replace it on the alley from which it fell, facing alley 1.
* All urine and faeces are removed between animals and the apparatus cleaned with a damp, followed by a dry tissue. It is important to clean and disinfect the equipment between each mouse tested.
* In addition, always wear gloves when handling rodents.