Method Article

Solid Phase Microextraction Sampling: A Probe-based Technique for Sample Extraction from Graft Tissues

April 30th, 2023

In This Article

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Source: Stryjak, I. et al. Using a Chemical Biopsy for Graft Quality Assessment. J. Vis. Exp. (2020)

In this video, we demonstrate SPME-probe-based extraction of metabolites from a pre-harvested donor kidney. The extracted metabolites can be used to perform metabolomic and lipidomic analysis in order to assess the organ quality for transplantation.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

All procedures involving human participants have been performed in compliance with the institutional, national and international guidelines for human welfare and have been reviewed by the local institutional review board.

1. Preparation of Probes

  1. Prepare titanium-nickel alloy probes (40 mm length; 0.2 mm diameter) coated with 7 mm mix-mode sorbent. The number of probes depends on the time points targeted during the entire procedure and the number of replicates (3 is recommended per time point).
    NOTE: The length and type of extraction phase may be adjusted based on the mode of study, the p....

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Acetic acidMerck5330010050Mobile phase additive
AcetonitrileAlchem696-34967-4X2.5LHPLC solvent
Ammonium acetateMerck5330040050Mobile phase additive
BENCHMIXER XL MULTI-TUBE VORTEXERBenchmark ScientificBV1010Vortex mixer
CapsPerlan Technologies5183-2076Blue scrw tp, pre-slit PTFE/Si spta, 100PK
ChloroformMerck1024441000
Discovery HS F5 Supelguard Cartridge, 3 μm, L × I.D. 2 cm × 2.1 mmMerck567570-UHPLC guard column
Discovery HS F5, 2.1 mm x 100 mm, 3 μmMerck567502-UHPLC column
Formic acidAlchem497-94318-50MLMobile phase additive
Glass vialsPerlan Technologies5182-0714
HILIC Luna 3 μm, 200A, 100 x 2.0 mmShim-PolPHX-00D-4449-B0HPLC column
HILIC SecurityGuard Cartridge, 3 μm, 4 x 2.0 mmShim-PolPHX-AJ0-8328HPLC guard column
IsopropanolAlchem231-AL03262500HPLC solvent
MethanolAlchem696-34966-4X2.5LHPLC solvent
Nano-pure waterMerck1037281002HPLC solvent
Q Exactive Focus hybrid quadrupole-Orbitrap MSThermo ScientificQ Exactive FocusMass Spectrometer
SeQuant ZIC-cHILIC 3µm,100Å 100 x 2.1 mmMerck1506570001HPLC column
SeQuant ZIC-HILIC Guard Kit 20 x 2.1 mmMerck1504360001HPLC guard column
SPME LC fiber probes, mixed modeSupelcoprototype fibers
UltiMate 3000 HPLC systemsThermo ScientificUltiMate 3000HPLC system
Vial inserts (deactivated)Perlan Technologies5181-8872
XSelect CSH C18 3.5μm 2.1x75mmWaters186005644HPLC column
XSelect CSH C18 VanGuard Cartridge 3.5μm, 2.1x5mmWaters186007811HPLC guard column

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Solid Phase MicroextractionSPME ProbeMetabolite ExtractionGraft Tissue SamplingOrgan Quality AssessmentHydroalcoholic CleaningActivation SolutionDesorption SolutionLC MS AnalysisSterile Processing

Related Articles