A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Kidney Flat Mount Preparation: A Procedure to Dissect and Prepare a Flat Mount for Microscopic Analysis of Adult Zebrafish Kidney

2.9K views

⸱

April 30th, 2023

In This Article

Abstract

Source: McCampbell, K. K. et al. Analysis of Nephron Composition and Function in the Adult Zebrafish Kidney. J. Vis. Exp. (2014)

This video demonstrates the dissection and preparation of a flat mount of the adult zebrafish kidney. The prepared flat mount can be visualized under the microscope for specimen analysis.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Dissection and Flat Mount Preparation of the Adult Zebrafish Kidney from an Unfixed Animal Sample to Visualize Fluorescent Dextran Labeling of the Proximal Tubule

  1. Euthanize the dextran-injected adult zebrafish by placing it into a dish with 0.2% Tricaine pH 7.0 for 4–5 min.
    NOTE: Ensure that the fish has been euthanized before proceeding, by monitoring carefully whether the gills have ceased movement and the heart has stopped beating.

Access restricted. Please log in or start a trial to view this content.

Results

Kidney microscopy; bright-field, dextran FITC; PCT analysis; fluoresces microscopy; microscopy images.
Figure 1. Adult zebrafish kidney flat mount preparation and application to visualize conjugated dextran uptake in the PCT segment of kidney nephrons. (A) Brightfield image of a kidney specimen flat mount preparation, in which the organ has been positi.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
1X PBSMade by diluting 10 X PBS in distilled water.
Fine Forceps Roboz RS-1050Dumont Tweezers Pattern #55
Glass slide  Thermo-Fisher4445White Frost
Glass coverslip Thermo-Fisher  12-540A18 x 18 mm
Modeling clay  HasbroPlaydohOther modeling clays can be substituted and work similarly. 
Slide holder  Thermo-Fisher12-587 Optional: cardboard tray to store slides flat.
StereomicroscopeNikonSMZ645; SMZ1000; 83455 P-Blue GFP/DAPI; 83457 P-Endow GFP/ FITC; 83457 P-TRITCFilter set used was as follows: Hoechst/DAPI filter was used for DAPI, propidium iodide, dextran-cascade blue and alkaline phosphatase detection. GFP/FITC filter was used for dextran-FITC, dextran lucifer yellow, and antiGFP detection. The TRITC filter was used for dextran-fluoro-ruby, PI, and DBA detection.
Compound microscope Nikon96310 C-FL UV-2E/C DAPI; 96311 C-FL B-2E/C FITC; 96313 C-FL Y-2E/C Texas RedFilter set used was as follows: Hoechst/DAPI filter was used for DAPI, propidium iodide, dextran-cascade blue and alkaline phosphatase detection. GFP/FITC filter was used for dextran-FITC, dextran lucifer yellow, and antiGFP detection. The Texas Red filter was used for dextran-fluoro-ruby, PI, and DBA detection.

Explore More Articles

Zebrafish Kidney DissectionConnective Tissue RemovalPBS WashingModeling Clay MountingCoverslip PlacementBody Wall PinningOrgan IsolationSlide Preparation