Method Article

Generating a Rabbit Calvarial Defect Model: A Surgical Procedure to Create Round Defects in the Top Portion of the Rabbit Skull to Assess Bone Substitute Materials for Bone Regeneration Capacities

July 8th, 2025

In This Article

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Source: Marger, L. et al., Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials. J. Vis. Exp. (2019).

In this video, we describe the surgical procedure to generate a rabbit calvarial model to evaluate the bone regeneration capacities of bone sample substitution materials of interest.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Surgery

  1. Site preparation
    1. Place the rabbit on a heated pad (39 °C) covered by a mattress pad (to avoid burns) on the surgery table. Shave the scalp.
    2. Apply a lubricating gel on the eyes to avoid irritation and dryness. Disinfect the site by scrubbing the skin with povidone iodine (10%). Then drape the rabbit with a sterile surgical drape and cut out an access area for the skull.
    3. Disinfect the surgical site with povidone iodine (10....

Access restricted. Please log in or start a trial to view this content.

Results

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Connector design diagram with dimensions for precise engineering and manufacturing.
Figure 1: Specifications of PEEK cylinders. Two holes (0.8 mm in diameter) were drilled on the lateral stabilizing tabs for screwing. The positions of the 5 intramedullary holes (0.8 mm in diameter) to be drilled on the skull within the area delimited by the cylinder ar.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
<strong>Drugs</strong>
FentanylBischelFor analgesia
Ketalar 50mg/mlPfizerKetamine for anesthesia
LidohexBichselLubricating gel for the eyes
OpsiteSmith and Nephew66004978Sprayable dressing
Povidone iodine 10%, BetadineMundipharmaanti-infective agent
Propofol 2%Braun3538710For anesthesia
Rapidocain 2%sinteticaLocal anesthesia
Rompun 2%BayerXylazin for anesthesia
Sevoflurane 5%AbbvieFor anesthesia
<strong>Equipment</strong>
Fresenius Vial pilot CImexmedInfusion pump
Heated padHarvard Apparatus
Suction dominant 50Medela
Suction tubing OptimusPromedical80342.2
Surgical motorSchick dentalQubeDrilling of intramedullary holes
VentilationMaquet Servo1
<strong>Material</strong>
Cylinders and capsBoutyplastCustomizedcomposition: PEEK (poly ether ether ketone)
Manual self-retaining shaftGlobalDACT1K
Mobile handle for self-retaining shaftGlobalDMTM
Self- drilling screwsGlobalDVA1.2KL4cross-drive screws composed by Titanium grade5, ISO 5832-3
<strong>Surgical tray</strong>
Endotracheal tube Shiley diameter 2,5mmCovidien86233For intubation
Endotracheal tube Shiley diameter 4,9mmCovidien107-35GFor intubation
Ethicon prolene 4-0Ehticon8581HNon-resorbable suture
ForcepsMarcel BlancBD027R145 mm
Intubation catheterCook medicalGuide for intubation
Round surgical bursPatterson780000.8 mm in diameter, Drilling of intramedullary holes
ScalpelSwann-Mortonn&deg;10 and n&deg;15
ScissorsMarcel Blanc657180 mm
Syringes OmnifixBraun4616057V5ml, 10ml and 50ml
Venflon G22Braun42690985-01Vasofix safety for the ear iv line

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Intramedullary DrillingCylinder PlacementBone Regeneration AssessmentPeriosteal ElevationSaline IrrigationSuture ClosurePost surgical Analgesia

Related Articles