A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

A Hemocyte Disturbance Assay to Assess Hemocyte Re-Adhesion to Hematopoietic Pockets

790 views

⸱

July 8th, 2025

In This Article

Abstract

Source: Petraki, S. et al., Assaying Blood Cell Populations of the Drosophila melanogaster Larva. J. Vis. Exp. (2015)

This video demonstrates the hemocyte disturbance assay, evaluating hemocyte re-adhesion in Drosophila larvae's hematopoietic pockets. Mechanical disturbance releases resident hemocytes, elevating circulating hemocyte counts. Post-recovery, re-adherence of resident hemocytes is confirmed, illustrating reversibility.

Protocol

1. Hemocyte Bleed/Scrape Assay

  1. Preparation of slides:
    1. Option 1 for microscopes without tile scanning function: For each larva to be analyzed, prepare one glass slide with about 5 Pap-pen wells of 2 mm squares each, corresponding to the field viewing area of the microscope; add approximately 5 - 10 µl of S2 media to each (Figure 1A). Keep slides in a moist chamber to prevent wells from drying out.
    2. Option 2 for microscopes with tile scanning function: For each larva to be analyzed, prepare one glass slide with 3 to 4 Pap-pen wells of ~3 - 4 mm squares each; add approximately 15 - 20 µl of S2 ....

Access restricted. Please log in or start a trial to view this content.

Results

Hemocyte assay diagram showing bleed/scrape and disturbance process in slide setups for cell counts.
Figure 1. Hemocyte Bleed/Scrape and Disturbance Assay setup and schematic. (A) Single Image Slide Setup: five 2mm squares for imaging with a 5X objective. (B) Tile Scan Slide Setup: four 3 mm squares for imaging bleed/scrapes of ≤.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
6cm/9cm Petri dishesOne for each genotype to be evaluated
Water squirt bottle
Metal spoon/spatula
Thin paintbrushe.g. a "liner"
Glass cavity dish
PAP pen: Super PAP PEN IM3580Beckman Coulter
Glass slidesEach slide will have 5 or more PAP PEN squares drawn on them. Size of squares depends on the imaging objective and magnification of the microscope camera; e.g. 2mm squares.
Moist chamberThis will be used to prevent slides and wells from drying out: sealed container with wet paper towels lining the sides/bottom
Schneider's Drosophila cell culture mediaInvitrogen
Cold blockThis is a metal block (a.k.a. heating block) chilled in bucket containing ice; preferably black-colored or other dark, non-reflective color
Two 1ml syringes with needles (27G ½)Becton DickinsonFor dissections.
Optional: Surgical spring scissors (cutting edge 2mm)Fine Science Tools
Glass beads, 212-600 micronSigma
2 ml Eppendorf tubesEppendorfOne per genotype evaluating
Vortex MixerFisher Scientific
Transgenic Drosophila larvae with fluorescently marked hemocytes. Suitable transgenes include: HmlΔ-DsRed (Makhijani et al., 2011), MSNF9mo-mCherry (Tokusumi et al., 2009), BcF6-CFP and -GFP (Gajewski et al., 2007), or HmlΔ-GAL4 (Sinenko and Mathey-Prevot, 2004), Pxn-GAL4 (Stramer et al., 2005), He-GAL4 (Zettervall et al., 2004), Crq-GAL4 (by H. Agaisse (Stramer et al., 2005)), or eater-GAL4 (Tokusumi et al., 2009) combined with UAS-GFP or other fluorescent protein transgenes.
Fluorescence dissecting microscopeLeicaHere: Leica M205, optional with camera, imaging software and measuring module
Inverted fluorescence microscope with camera attachmentLeica or KeyenceWith or without tile scanning function (eg. Leica DMI series, Keyence BIOREVO BZ-9000 series)

Explore More Articles

Drosophila LarvaeGlass Bead VortexingFluorescence MicroscopyCirculating HemocytesResident HemocytesBleed-Scrape DissectionRecovery Phase